Micro-Introducer Set
2 catalogue numbers from INT-112-06, listed by Galt Medical Corp., United States, under Dilator, Vessel, For Percutaneous Catheterization. 1 manufacturer in China is registered for this product code.
Who Else Makes It
Registered in Guangdong.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Lifetech Scientific (Shenzhen) Co,.ltd | Shenzhen | Guangdong | Manufacturer | 3 |
Record
| Listed by | Galt Medical Corp., United States |
|---|---|
| FDA product code | DRE |
| Device type | Dilator, Vessel, For Percutaneous Catheterization |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1310 |
| Establishment | Contract manufacturer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| Record published | 2017-08-09 |
| Record revised | 2026-05-25 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Ethylene Oxide |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, serial number |
| Packaging | Shipper box of 100, shelf box of 10, shipper box of 25, shelf box of 5 |
| Sizes | Catheter gauge 4 Fr |
| Distribution end date | 2023-02-21 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| INT-112-06 | Catheter Gauge 4 Fr | Withdrawn |
| INT-112-10 | Catheter Gauge 4 Fr | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Prelude® | Merit Medical Systems, Inc. | 323 |
| Prelude PRO™ | Merit Medical Systems, Inc. | 132 |
| Cook | Cook Incorporated | 125 |
| Avanti | Cordis Corp. | 81 |
| Dilator, Vessel, For Percutaneous Catheterization | B. Braun Interventional Systems, Inc. | 59 |
| Merit MAK™ | Merit Medical Systems, Inc. | 49 |
| Prelude ACT™ | Merit Medical Systems, Inc. | 38 |
| AngioDynamics | Navilyst Medical, Inc. | 38 |
| Super Sheath | Togo Medikit Co., Ltd. | 31 |
| Avanti | Cordis US Corp. | 29 |
| Mini Stick MAX | AngioDynamics, Inc. | 28 |
| OneStic Micro-Access Introducer | Argon Medical Devices, Inc. | 27 |
Showing 12 of 159. All products under Dilator, Vessel, For Percutaneous Catheterization
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K192195 | 2019-09-26 |
| K172487 | 2017-10-16 |
| K071330 | 2007-10-31 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-03-27 | Class II | Process control | Due to a potential open seal in the sterile barrier packaging. | 1,400 dilators | |
| 2018-05-02 | Class II | Other | The products listed might contain unsafe levels of bacterial endotoxins (Pyrogens) that were introduced during a manufacturing step. Bacterial Endotoxins also called pyrogenic bacteria can activate the inflammatory process and produce fever | 8350 | 2020-07-20 |
| 2010-02-08 | Not classified | Packaging process control | Potential problem with pouch seal thus affecting sterile product. | 400 units | 2011-03-21 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.