Direxion™ Fathom™-16 System

10 catalogue numbers from M001195630, listed by Boston Scientific Corporation, United States, under Catheter, Continuous Flush. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
10catalogue numbers in this listing
11510(k) clearances naming this product code
7recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (1), Guangdong (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code KRA
Manufacturer City Province Registered as Device types
Shanghai Wallaby Medical Technologies Co., Inc. Shanghai Shanghai Contract manufacturer 5
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Suzhou Zenith Vascular Scitech Limited Suzhou Jiangsu Manufacturer 6
Suzhou Hengrui Hongyuan Medical Co., Ltd. Suzhou Jiangsu Manufacturer 3
Vascupatent Medical (Shenzhen) Co., Ltd. Shenzhen Guangdong Manufacturer 1

Record

Regulatory record for Direxion™ Fathom™-16 System
Listed by Boston Scientific Corporation, United States
FDA product code KRA
Device type Catheter, Continuous Flush
Device class Class 2
Regulation 21 CFR 870.1210
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2019-07-25
Record revised 2019-03-21 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Sizes Catheter inner diameter 0.021 in; catheter working length 155 cm; guidewire length 200 cm
Distribution end date 2021-09-29

Catalogue Numbers

Catalogue numbers for Direxion™ Fathom™-16 System
Catalogue number Size Status
M001195630 0.021 in Diameter In distribution
M001195650 180 cm Length In distribution
M001195610 0.021 in Diameter In distribution
M001195670 180 cm Length In distribution
M001195660 0.021 in Diameter In distribution
M001195620 180 cm Length In distribution
M001195640 0.021 in Diameter In distribution
M001195600 0.021 in Diameter In distribution
M001195990 Catheter Inner Diameter 0.021 in Withdrawn
M001195980 Catheter Inner Diameter 0.021 in Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Fountain® Merit Medical Systems, Inc. 154
PulseSpray AngioDynamics, Inc. 149
Merit Maestro® Merit Medical Systems, Inc. 143
Phenom™ Catheter Cathera, Inc. 103
UniFuse AngioDynamics, Inc. 84
CXI Cook Incorporated 48
Uni-Fuse+ AngioDynamics, Inc. 32
Prowler Medos International Sàrl 27
Truwave, Vamp Edwards Lifesciences Technology Sarl 26
ICU Medical ICU Medical, Inc 21
Cantata Cook Incorporated 20
Truwave, Vamp Plus Edwards Lifesciences Technology Sarl 19

Showing 12 of 149. All products under Catheter, Continuous Flush

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K260771 2026-05-15
K201792 2020-07-28
K163701 2017-05-16
K142259 2014-09-10
K140329 2014-05-15
K132947 2013-10-18
K100892 2010-04-12
K000177 2000-04-07
K973645 1997-11-19
K963988 1996-12-12
K945666 1995-06-21

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-11-03 Class II Device Design This is a follow-up to the EKOS Field Safety Notice dated April 30, 2019. The Radio Frequency (RF) board has been redesigned to prevent occasional internal board failures at lower temperatures. All EKOS CU 4.0 consoles containing the old RF 90 (OUS)
2009-08-26 Not classified Packaging Boston Scientific has determined that the sterile barrier in the packaging of the affected product may be compromised. It has been reported that the pouch seal (top seal) may be breached. 9,088 2012-08-24
2009-08-26 Not classified Packaging Boston Scientific has determined that the sterile barrier in the packaging of the affected product may be compromised. It has been reported that the pouch seal (top seal) may be breached. 28,947 (11,050 US; 17,897 OUS) 2012-08-24
2009-08-26 Not classified Packaging Boston Scientific has determined that the sterile barrier in the packaging of the affected product may be compromised. It has been reported that the pouch seal (top seal) may be breached. 80,885 (51,491 US; 29,394 OUS) 2012-08-24
2009-08-24 Not classified Packaging process control Sterility Loss– The sterile barrier pouch seal (top seal) may be breached by the product, resulting in loss of sterility which may result in transmission of disease or infection. 2011-02-03
2009-08-24 Not classified Packaging process control Sterility Loss– The sterile barrier pouch seal (top seal) may be breached by the product, resulting in loss of sterility which may result in transmission of disease or infection. 2011-02-03
2007-09-10 Not classified Packaging process control Incorrect Guidewire: Product may incorrectly contain a 135 cm length Transend-18 guidewire instead of the kit labeled 165 cm length Transend-18 guidewire. 153 2007-12-20

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer