Swan-Ganz VIP
Swan-Ganz VIP/Oximetry Thermodilution Catheter
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (1), Guangdong (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Suzhou Hengrui Hongyuan Medical Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
| Vascupatent Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 1 |
Record
| Listed by | Edwards Lifesciences Technology Sarl, United States |
|---|---|
| FDA product code | KRA |
| Device type | Catheter, Continuous Flush |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1210 |
| Establishment | Contract manufacturer, Specification developer, Manufacturer |
| 510(k) | K160084 |
| Record published | 2016-09-03 |
| Record revised | 2023-12-04 (version 6) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Contains natural rubber latex |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: STORE IN A COOL, DRY PLACE |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 782F75M | USABLE LENGTH: 110CM, EXTERIOR DIAMETER: 7.5F (2.5MM), MINIMUM INTRODUCER SIZE: 8.5F (2.8MM), RECOMMENDED GUIDEWIRE SIZE: 0.025 IN (0.64MM) | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Fountain® | Merit Medical Systems, Inc. | 154 |
| PulseSpray | AngioDynamics, Inc. | 149 |
| Merit Maestro® | Merit Medical Systems, Inc. | 143 |
| Phenom™ Catheter | Cathera, Inc. | 103 |
| UniFuse | AngioDynamics, Inc. | 84 |
| CXI | Cook Incorporated | 48 |
| Uni-Fuse+ | AngioDynamics, Inc. | 32 |
| Prowler | Medos International Sàrl | 27 |
| Truwave, Vamp | Edwards Lifesciences Technology Sarl | 26 |
| ICU Medical | ICU Medical, Inc | 21 |
| Cantata | Cook Incorporated | 20 |
| Truwave, Vamp Plus | Edwards Lifesciences Technology Sarl | 19 |
Showing 12 of 149. All products under Catheter, Continuous Flush
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K181684 | 2018-11-08 |
| K180275 | 2018-10-24 |
| K173586 | 2018-04-05 |
| K161962 | 2016-11-28 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Edwards Lifesciences Technology Sarl | 510(k) number | 2018-12-21 | Class I | Nonconforming Material/Component | These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. | 277 units | 2023-11-02 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2018-12-21 | Class I | Nonconforming Material/Component | These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. | 875 units | 2023-11-02 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2018-12-21 | Class I | Nonconforming Material/Component | These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. | 9 units | 2023-11-02 |
| Edwards Lifesciences Technology Sarl | 510(k) number | 2018-12-21 | Class I | Nonconforming Material/Component | These Swan Ganz catheters have incorrect lumen assembly, which causes reversal of the lumens. If the lumens are reversed the clinician may note reverse PA and CVP pressure values and waveforms. | 459 units | 2023-11-02 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2013-01-30 | Class II | Process change control | The device is being recalled because the firm has received multiple complaints related to incorrect assembly that may result in dilution of blood samples. | 30,467 | 2016-03-10 |
| 2009-02-09 | Not classified | Software design | Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. | 2,728 units | 2011-04-11 |
| 2009-02-09 | Not classified | Software design | Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. | 107 units | 2011-04-11 |
| 2009-02-09 | Not classified | Software design | Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. | 35 units | 2011-04-11 |