Truwave X 3 (3 CC)/Vamp Plus (215 CM)
Catalogue number T100671M, listed by Edwards Lifesciences Technology Sarl, United States, under Catheter, Continuous Flush. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (1), Guangdong (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shanghai Wallaby Medical Technologies Co., Inc. | Shanghai | Shanghai | Contract manufacturer | 5 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Suzhou Hengrui Hongyuan Medical Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 3 |
| Vascupatent Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 1 |
Record
| Listed by | Edwards Lifesciences Technology Sarl, United States |
|---|---|
| FDA product code | KRA |
| Device type | Catheter, Continuous Flush |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1210 |
| Establishment | Contract manufacturer, Specification developer, Manufacturer |
| 510(k) | K181684 |
| Record published | 2020-04-24 |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: STORE IN A COOL, DRY PLACE |
| Packaging | Shipper of 10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| T100671M | Volume 3 cc, length 215 cm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Fountain® | Merit Medical Systems, Inc. | 154 |
| PulseSpray | AngioDynamics, Inc. | 149 |
| Merit Maestro® | Merit Medical Systems, Inc. | 143 |
| Phenom™ Catheter | Cathera, Inc. | 103 |
| UniFuse | AngioDynamics, Inc. | 84 |
| CXI | Cook Incorporated | 48 |
| Uni-Fuse+ | AngioDynamics, Inc. | 32 |
| Prowler | Medos International Sàrl | 27 |
| Truwave, Vamp | Edwards Lifesciences Technology Sarl | 26 |
| ICU Medical | ICU Medical, Inc | 21 |
| Cantata | Cook Incorporated | 20 |
| Truwave, Vamp Plus | Edwards Lifesciences Technology Sarl | 19 |
Showing 12 of 149. All products under Catheter, Continuous Flush
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K181684 | 2018-11-08 |
| K180275 | 2018-10-24 |
| K173586 | 2018-04-05 |
| K161962 | 2016-11-28 |
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Edwards Lifesciences Technology Sarl | UDI-DI | 2023-10-04 | Class II | Device Design | Their is the potential for flushing difficulties during setup of the pressure monitoring kit with pressure transducer. | 168,014 units |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2013-01-30 | Class II | Process change control | The device is being recalled because the firm has received multiple complaints related to incorrect assembly that may result in dilution of blood samples. | 30,467 | 2016-03-10 |
| 2009-02-09 | Not classified | Software design | Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. | 2,728 units | 2011-04-11 |
| 2009-02-09 | Not classified | Software design | Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. | 107 units | 2011-04-11 |
| 2009-02-09 | Not classified | Software design | Cardiac output measurements were unavailable and the following message is displayed in the Vigilance monitor: “Fault. CCO Catheter Verification. Use Bolus Mode”. | 35 units | 2011-04-11 |