ApexPro
600MHZ Telemetry Receiver 3ED ATO
Who Else Makes It
Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Shenzhen Comen Medical Instruments Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Guangdong Biolight Meditech Co., Ltd. | Zhuhai | Guangdong | Manufacturer | 19 |
| Shanghai Draeger Medical Instrument Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 4 |
| General Meditech, Inc. | Shenzhen | Guangdong | Complaint-file establishment | 3 |
Record
| Listed by | GE Medical Systems Information Technologies, Inc., United States |
|---|---|
| FDA product code | MHX |
| Device type | Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1025 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K080251 |
| Record published | 2016-06-10 |
| Record revised | 2026-02-23 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment temperature -40 to 70 °C |
| Distribution end date | 2022-10-10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 600 MHz Receiver | In distribution | |
| CH Transmitter | Withdrawn | |
| FH Transceiver | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Fukuda Denshi | Fukuda Denshi Co., Ltd. | 326 |
| Welch Allyn, Inc. | Welch Allyn, Inc. | 266 |
| Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) | Nihon Kohden Corp. | 205 |
| Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) | Nihon Kohden America, Inc. | 139 |
| Surveyor Central | Mortara Instrument, Inc. | 71 |
| Tempus Pro | Remote Diagnostic Technologies Ltd. | 44 |
| Surveyor S12 | Mortara Instrument, Inc. | 38 |
| Ultraview | Spacelabs Healthcare (Washington), Inc | 29 |
| Surveyor S19 | Mortara Instrument, Inc. | 26 |
| Vital Signs™ | AirLife Finland Oy | 23 |
| Patient Monitor | Edan Instruments, Inc. | 22 |
| Telemetry Accessories | Philips Medizin Systeme Böblingen GmbH | 21 |
Showing 12 of 589. All products under Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K253277 | 2026-07-24 |
| K242562 | 2025-07-09 |
| K222586 | 2022-12-21 |
| K221904 | 2022-12-20 |
| K213234 | 2022-04-12 |
| K213490 | 2022-04-01 |
| K201941 | 2020-11-04 |
| K170155 | 2017-06-06 |
| K141963 | 2015-02-05 |
| K092369 | 2010-02-24 |
| K092027 | 2009-08-28 |
| K091594 | 2009-07-29 |
| K090702 | 2009-04-15 |
| K083750 | 2009-03-23 |
| K080251 | 2008-06-20 |
| K080157 | 2008-03-24 |
| K073462 | 2008-01-11 |
| K073203 | 2007-11-29 |
| K071073 | 2007-05-11 |
| K060833 | 2006-08-01 |
| K051367 | 2005-06-20 |
| K042642 | 2004-11-03 |
| K040458 | 2004-06-03 |
| K033964 | 2004-01-15 |
| K033492 | 2003-11-24 |
| K033304 | 2003-11-12 |
| K033365 | 2003-11-06 |
| K032369 | 2003-08-15 |
| K031376 | 2003-07-16 |
| K022834 | 2003-05-13 |
| K031320 | 2003-05-06 |
| K030575 | 2003-03-21 |
| K030431 | 2003-02-26 |
| K012915 | 2002-03-21 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| GE Medical Systems Information Technologies, Inc. | 510(k) number | 2026-04-24 | Class II | Software design | GE HealthCare has become aware of an unlikely situation where potential loss of ECG and SpO2 monitoring involving ApexPro CARESCAPE Telemetry Server (CTS) v5.0 and v6.0, can result from a persistent NO COMM or OFF NETWORK condition at the C | 476 units | |
| GE Medical Systems, LLC | 510(k) number | 2011-01-28 | Not classified | Software design | GE Healthcare has become aware of a potential for loss of patient monitoring when ApexPro Telemetry System is used in conjunction with a mirrored view CARESCAPE CIC Pro in combination monitoring mode (combo mode). The safety issue includes | 2346 | 2012-05-29 |
Recalls
6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2026-04-24 | Class II | Software design | GE HealthCare has become aware of an unlikely situation where potential loss of ECG and SpO2 monitoring involving ApexPro CARESCAPE Telemetry Server (CTS) v5.0 and v6.0, can result from a persistent NO COMM or OFF NETWORK condition at the C | 2187 units | |
| 2026-04-24 | Class II | Software design | GE HealthCare has become aware of an unlikely situation where potential loss of ECG and SpO2 monitoring involving ApexPro CARESCAPE Telemetry Server (CTS) v5.0 and v6.0, can result from a persistent NO COMM or OFF NETWORK condition at the C | 2366 units | |
| 2026-04-24 | Class II | Software design | GE HealthCare has become aware of an unlikely situation where potential loss of ECG and SpO2 monitoring involving ApexPro CARESCAPE Telemetry Server (CTS) v5.0 and v6.0, can result from a persistent NO COMM or OFF NETWORK condition at the C | 14 units | |
| 2026-04-24 | Class II | Software design | GE HealthCare has become aware of an unlikely situation where potential loss of ECG and SpO2 monitoring involving ApexPro CARESCAPE Telemetry Server (CTS) v5.0 and v6.0, can result from a persistent NO COMM or OFF NETWORK condition at the C | 1249 units | |
| 2026-04-24 | Class II | Software design | GE HealthCare has become aware of an unlikely situation where potential loss of ECG and SpO2 monitoring involving ApexPro CARESCAPE Telemetry Server (CTS) v5.0 and v6.0, can result from a persistent NO COMM or OFF NETWORK condition at the C | 7 units | |
| 2017-07-13 | Class II | Software Design Change | Device does not produce a visual or audible impedance respiration APN alarm when an impedance respiration apnea event occurs. | 1,196 (1,176 US; 20 OUS) | 2021-04-01 |
| 2004-01-27 | Not classified | Other | The potential exists for external electrical noise to be processed as irregular pacing thereby masking potential asystole events. | 36 | 2009-10-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.