Tempus Pro
Invasive Pressure Cable 2 Channel - Transpac & Art-Line 8ft
Who Else Makes It
Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Shenzhen Comen Medical Instruments Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Guangdong Biolight Meditech Co., Ltd. | Zhuhai | Guangdong | Manufacturer | 19 |
| Shanghai Draeger Medical Instrument Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 4 |
| General Meditech, Inc. | Shenzhen | Guangdong | Complaint-file establishment | 3 |
Record
| Listed by | Remote Diagnostic Technologies Ltd., United Kingdom |
|---|---|
| FDA product code | MHX |
| Device type | Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1025 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| Record published | 2017-06-30 |
| Record revised | 2024-04-04 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date, serial number |
| Packaging | Box of 10 |
| Distribution end date | 2025-11-13 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 01-2068 | In distribution | |
| 01-2113 | In distribution | |
| 01-2002 | In distribution | |
| 01-2051 | In distribution | |
| 01-2108 | In distribution | |
| 01-2004 | In distribution | |
| 00-1026-R | In distribution | |
| 01-2179 | In distribution | |
| 01-2186 | In distribution | |
| 01-2244 | In distribution | |
| 01-2182 | In distribution | |
| 01-2003 | In distribution | |
| 01-2177 | In distribution | |
| 01-2203 | In distribution | |
| 01-2048 | In distribution | |
| 01-2070 | In distribution | |
| 00-1007-R | In distribution | |
| 01-2069 | In distribution | |
| 00-1024-R | In distribution | |
| 01-2501 | In distribution | |
| 01-2052 | In distribution | |
| 01-2243 | Withdrawn | |
| 01-2017 | Withdrawn | |
| 01-2111 | Withdrawn | |
| 01-2053 | Withdrawn | |
| 00-1004-R | Withdrawn | |
| 00-1007 | Withdrawn | |
| 00-1026-R | Withdrawn | |
| 00-1004-R | Withdrawn | |
| 01-1012 | Withdrawn | |
| 01-2112 | Withdrawn | |
| 00-1006 | Withdrawn | |
| 01-2110 | Withdrawn | |
| 01-2049 | Withdrawn | |
| 01-2115 | Withdrawn | |
| 01-2114 | Withdrawn | |
| 00-1007-R | Withdrawn | |
| 01-2184 | Withdrawn | |
| 00-1034-R | Withdrawn | |
| 00-1036-R | Withdrawn | |
| 00-1004 | Withdrawn | |
| 01-2101 | Withdrawn | |
| 00-1024-R | Withdrawn | |
| 00-1005 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Fukuda Denshi | Fukuda Denshi Co., Ltd. | 326 |
| Welch Allyn, Inc. | Welch Allyn, Inc. | 266 |
| Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) | Nihon Kohden Corp. | 205 |
| Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) | Nihon Kohden America, Inc. | 139 |
| Surveyor Central | Mortara Instrument, Inc. | 71 |
| Surveyor S12 | Mortara Instrument, Inc. | 38 |
| Ultraview | Spacelabs Healthcare (Washington), Inc | 29 |
| Surveyor S19 | Mortara Instrument, Inc. | 26 |
| Vital Signs™ | AirLife Finland Oy | 23 |
| Patient Monitor | Edan Instruments, Inc. | 22 |
| Telemetry Accessories | Philips Medizin Systeme Böblingen GmbH | 21 |
| Spacelabs Healthcare | Spacelabs Healthcare (Washington), Inc | 20 |
Showing 12 of 589. All products under Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K201746 | 2020-09-18 |
| K173768 | 2018-01-10 |
| K170567 | 2017-07-06 |
Recalls Naming This Product
6 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Remote Diagnostic Technologies Ltd. | UDI-DI | 2025-11-26 | Class II | Device Design | Patient monitor measures Intracranial Pressure (ICP) and Bladder Pressure (BDR) but ICP and BDR measurements have not been tested or validated for accuracy. If healthcare providers base clinical judgment on unvalidated measurements, this co | 7129 |
| Remote Diagnostic Technologies Ltd. | UDI-DI | 2025-05-30 | Class II | Software change control | Kit USB flash drive contains outdated software, which could result in reverting patient monitor to outdated software and reintroducing the video laryngoscope issue (related to an August 2023 recall), which could lead to delay in diagnosis, | 55 |
| Remote Diagnostic Technologies Ltd. | UDI-DI | 2025-04-16 | Class II | Device Design | software issue that causes an error screen on a portable vital signs monitor when attaching video Laryngoscope. | 6,961 units |
| Remote Diagnostic Technologies Ltd. | UDI-DI | 2025-04-15 | Class II | Software design | Patient Monitor software update to address issues:1)May freeze at startup with MPM Application error and Attention Restart Required messages,2)Monitor may freeze and reboot at start of 12-lead ECG or after, 3)May reboot after intermittent c | 6961 |
| Remote Diagnostic Technologies Ltd. | UDI-DI | 2023-08-24 | Class II | Device Design | Full screen error message may occur on patient monitors with affected hardware version, either during or after laryngoscopes are unplugged from monitors, informing users a 60-100 second shutdown/restart are required. Error prevents: viewing | 3,524 |
| Remote Diagnostic Technologies Ltd. | UDI-DI | 2021-05-25 | Class II | Software design | The Tempus Pro (Trizeps 7 only) when used in combination with a specified laryngoscope device can cause two error types when subsequently unplugged. | 510 systems |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2023-02-23 | Class II | Under Investigation by firm | During internal testing, Regulatory Compliance issues were identified regarding the Monitor and Power Supplies for fluid ingress and basic safety issues. | 5,540 units |