Spacelabs Healthcare

Miscellaneous power supply, supplies or other accessories

Registry build 21.09.26
9manufacturers in China registered for this device type
20catalogue numbers in this listing

Who Else Makes It

Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MHX
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Shenzhen Comen Medical Instruments Co., Ltd. Shenzhen Guangdong Contract manufacturer 24
Contec Medical Systems Co., Ltd. Qinhuangdao Hebei Manufacturer 22
Guangdong Biolight Meditech Co., Ltd. Zhuhai Guangdong Manufacturer 19
Shanghai Draeger Medical Instrument Co., Ltd. Shanghai Shanghai Contract manufacturer 4
General Meditech, Inc. Shenzhen Guangdong Complaint-file establishment 3

Record

Regulatory record for Spacelabs Healthcare
Listed by Spacelabs Healthcare (Washington), Inc
FDA product code MHX
Device type Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
Device class Class 2
Regulation 21 CFR 870.1025
510(k) K121480
Record published 2016-11-21
Record revised 2024-05-03 (version 10)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, manufacturing date, serial number
Storage Storage environment temperature 0 to 0 °C; Storage environment humidity 0 to 0 % RH
Distribution end date 2020-11-30

Catalogue Numbers

Catalogue numbers for Spacelabs Healthcare
Catalogue number Size Per pack Status
Elance In distribution
SUPPLY In distribution
Elance In distribution
91388 In distribution
Elance In distribution
SUPPLY In distribution
SUPPLY In distribution
SUPPLY In distribution
93300 In distribution
SUPPLY 3 Withdrawn
SUPPLY 3 Withdrawn
SUPPLY 3 Withdrawn
96280 Withdrawn
96280 Withdrawn
SUPPLY 3 Withdrawn
SUPPLY 5 Withdrawn
SUPPLY 3 Withdrawn
SUPPLY Withdrawn
94267 Withdrawn
93300 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Fukuda Denshi Fukuda Denshi Co., Ltd. 326
Welch Allyn, Inc. Welch Allyn, Inc. 266
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) Nihon Kohden Corp. 205
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) Nihon Kohden America, Inc. 139
Surveyor Central Mortara Instrument, Inc. 71
Tempus Pro Remote Diagnostic Technologies Ltd. 44
Surveyor S12 Mortara Instrument, Inc. 38
Ultraview Spacelabs Healthcare (Washington), Inc 29
Surveyor S19 Mortara Instrument, Inc. 26
Vital Signs™ AirLife Finland Oy 23
Patient Monitor Edan Instruments, Inc. 22
Telemetry Accessories Philips Medizin Systeme Böblingen GmbH 21

Showing 12 of 589. All products under Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)

Recalls Naming This Product

18 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Spacelabs Healthcare
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Spacelabs Healthcare Ltd. 510(k) number 2025-09-05 Class II Device Design Due to display cables used for monitors were not in compliance with electromagnetic interference from inadequately shielded cables which may pose serious risk to patient’s safety by interfering with the operation of another electronically s 8179
Spacelabs Healthcare Ltd. 510(k) number 2025-09-05 Class II Device Design Due to display cables used for monitors were not in compliance with electromagnetic interference from inadequately shielded cables which may pose serious risk to patient’s safety by interfering with the operation of another electronically s 820
Spacelabs Healthcare Ltd. 510(k) number 2025-09-05 Class II Device Design Due to display cables used for monitors were not in compliance with electromagnetic interference from inadequately shielded cables which may pose serious risk to patient’s safety by interfering with the operation of another electronically s 16898
Spacelabs Healthcare Ltd. 510(k) number 2024-11-25 Class II Labeling design Telemetry receiver systems may experience a Windows proxy Issue causing the system to shut down and restart (Offline displayed), lasting approximately 1 to 1.5 minutes, which will cause temporary loss of monitoring. If a clinical event occu 2265
Spacelabs Healthcare Ltd. 510(k) number 2024-11-25 Class II Software change control Telemetry receivers with affected software versions may experience unsolicited system shut down and restart (Offline displayed), lasting approximately 1 to 1.5 minutes, which will cause temporary loss of monitoring. If a clinical event occu 434
Spacelabs Healthcare Ltd. 510(k) number 2022-05-31 Class II Software Design Change Software related alarm escalation defect occurs after approximately 25 days of continuous use. Technical alarm escalation for the following alarms, signal loss, all leads off, low battery, SpO2 sensor off, and signal interference, does not 529
Spacelabs Healthcare Ltd. 510(k) number 2018-01-17 Class II Under Investigation by firm Spacelabs has received multiple complaints reporting telemetry beds dropping off the Spacelabs Central Station resulting in a loss of monitoring. 12 systems 2018-11-29
Spacelabs Healthcare Ltd. 510(k) number 2016-08-25 Class II Software design The firm received multiple reports of Xhibit Telemetry System going offline or locking up. In addition, short-duration asystole alarms may not display an audio and visual alarm as reported from a single Canadian hospital. 316 XTR units total (248 units in the US and 68 units outsid 2017-03-13
Spacelabs Healthcare Ltd. 510(k) number 2016-03-28 Class II Other Reports of an abnormally high frequency of squelch events on Xhibit Telemetry Receivers (XTR), which is indicative of the loss of the telemetry data signal. In some cases, the Xhibit Central Monitor was also reported to display an Xhibit Of 217 units of XTRs and 531 units of PCBAs (164 XTRs and 425 P 2016-12-19
Spacelabs Healthcare Ltd. 510(k) number 2015-01-28 Class II Device Design Spacelabs Healthcare XPREZZON Bedside Monitors, Model 91393, are recalled because the firm has received multiple reports of XPREZZON monitors failing to boot up or returning to factory default configuration settings following power on or re total 1578 units (702 units in the US and 876 outside US) 2015-12-30
Spacelabs Healthcare Ltd. 510(k) number 2014-08-26 Class II Environmental control The clinician did not realize the monitor was in END CASE mode and was expecting audible alarms. Visual alarms continue to work normally.

The firm performed a retrospective analysis of all recalls since 2011 and discovered 222 additional s

82 units distributed in US and 140 units distributed outside 2015-06-26
Spacelabs Healthcare Ltd. 510(k) number 2014-07-02 Class II Software design The transmitter display and the Telemetry Central Station display may show a SpO2 value when the sensor is not connected to the patient or in certain sensor failed conditions.

This is an expansion of recall Z-0871-2014 because additional s

8 units 2014-10-16
Spacelabs Healthcare Ltd. 510(k) number 2013-12-19 Class II Software design The AriaTele Model 96281 with SpO2 monitoring Option C is recalled because the AriaTele (transmitter) display and the Telemetry Central Station display may show a SpO2 value when the sensor is not connected to the patient or in certain sens 1057 units (988 in the US and 69 outside of the US). 2014-06-12
Spacelabs Healthcare Ltd. 510(k) number 2012-10-05 Class II Vendor change control Potential failure of Spacelabs Healthcare Touchscreen Display, Model 94267 where the alarm lights failed to illuminate upon installation. 169 units distributed (98 in US and 71 Internationally) 2013-03-25
Spacelabs Healthcare Ltd. 510(k) number 2012-06-12 Class II Software design There were reports that a certain combination of key presses will cause the module to disconnect from the Xprezzon bedside monitor, model 91393, and the patient parameters will drop from the display. The parameters return after power cyclin 21 units 2012-11-28
Spacelabs Healthcare Ltd. 510(k) number 2012-05-22 Not classified Device Design The screw used to connect the external power supply to the Spacelabs Medical Xprezzon Bedside Monitor, Model 91393, may damage an internal capacitor. The damage may result in an inability of the monitor to power on, power off, or involunta 1898 monitors (Domestic: 1188) (International: 710) 2013-05-07
Spacelabs Healthcare Ltd. 510(k) number 2011-07-08 Not classified Device Design The clinician did not realize the monitor was in END CASE mode and was expecting audible alarms.

Visual alarms continue to work normally.

total 2812 units distributed worldwide 2012-05-23
Spacelabs Healthcare Ltd. 510(k) number 2011-03-24 Not classified Other The circuit that supplies backup power to the modules in the Medical Patient Monitor, Model 91387, is not working. If there is a power interruption, the three-minute backup may not be operational and customers may lose any changes they hav 4470 units total (1894 units in US and 2579 units internatio 2012-02-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability.

Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer