Argus PB-3000

The ARGUS PB-3000 is described as a vital-data acquisition unit used within or connected to a host medical device or system. It receives patient signals from external sensors and…

Registry build 21.09.26

The ARGUS PB-3000 is described as a vital-data acquisition unit used within or connected to a host medical device or system. It receives patient signals from external sensors and communicates with the host.

The filing says data is sent to the host over a network connection without storing vital or demographic data on the PB-3000. Depending on variant, modules support ECG, respiration, invasive blood pressure, temperature, cardiac output, SpO2, CO2, or non-invasive blood pressure.

Listed Item

“The ARGUS PB-3000 is a vital data acquisition unit intended to be used within or connected to a medical device or a medical System (Host System) for acquiring, analysing, and transmission of patient vitals and other pertinent clinical data of following vital date of a patient: ECG and Respiration ECG, heart rate, asystole time, respiration rate and apnoea time for monitoring and diagnostic purpose. IBP The IBP measurement is intended for continuously invasive measurement of a patient’s arterial and/or venous blood pressure in different locations. NIBP The NIBP measurement is intended for non-invasive measure blood pressure with different cuffs in different locations. SpO2 The SpO2 measurement is intended for non-invasive measuring of a patient’s oxygen saturation level and other parameters (e.g. SpCO, SpMet). CO2 and Respiration The CO2 measurement is intended for the non-invasive monitoring of a patient’s in and exhaled carbon dioxide, anaesthesia gases and to provide a respiration rate. Cardiac Output (CO) The Cardiac Output measurement is intended for measuring continuously blood and injected fluid temperature for calculating the current Cardiac Output of a patient in the medical system (Host System). Temperature The Temperature measurement is intended for non-invasive and invasive measurement of a patient’s temperature in different locations.”

Data Flow and Configuration

The filing says the third-party host-system manufacturer chooses which PB-3000 variant to implement in its host system.

9manufacturers in China registered for this device type
17catalogue numbers in this listing
4510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MHX
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Shenzhen Comen Medical Instruments Co., Ltd. Shenzhen Guangdong Contract manufacturer 24
Contec Medical Systems Co., Ltd. Qinhuangdao Hebei Manufacturer 22
Guangdong Biolight Meditech Co., Ltd. Zhuhai Guangdong Manufacturer 19
Shanghai Draeger Medical Instrument Co., Ltd. Shanghai Shanghai Contract manufacturer 4
General Meditech, Inc. Shenzhen Guangdong Complaint-file establishment 3

Record

Regulatory record for Argus PB-3000
Listed by Schiller AG, Switzerland
FDA product code MHX
Device type Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
Device class Class 2
Regulation 21 CFR 870.1025
Establishment Contract manufacturer, Private-label distributor, Manufacturer, Exporter
510(k) K221056
Record published 2023-09-04
Record revised 2024-09-13 (version 2)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Handling environment temperature -10 to 50 °C; Storage environment temperature 5 to 50 °C; Handling environment humidity 10 to 95 % RH; Handling environment atmospheric pressure 50 to 106 KiloPascal

Catalogue Numbers

Catalogue numbers for Argus PB-3000
Catalogue number Size Status
PB-3000 Var.7, sub-variant: SAG In distribution
PB-3000 Var.9, sub-variant: LB In distribution
PB-3000 Var.3, sub-variant: SAG In distribution
PB-3000 Var.1, sub-variant: S In distribution
PB-3000 Var.8, sub-variant: Q In distribution
PB-3000 Var.1, sub-variant: SAG In distribution
PB-3000 Var.5, sub-variant: SAG In distribution
PB-3000 Var.7, sub-variant: M/I In distribution
PB-3000 Var.6, sub-variant: SAG In distribution
PB-3000 Var.2, sub-variant: SAG In distribution
PB-3000 Var.2, sub-variant: S In distribution
PB-3000 Var.10, sub-variant: M/I In distribution
PB-3000 Var.5, sub-variant: S In distribution
PB-3000 Var.4, sub-variant: SAG In distribution
PB-3000 Var.7, sub-variant: C In distribution
PB-3000 Var.9, sub-variant: Q In distribution
PB-3000 Var.7, sub-variant: S In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Fukuda Denshi Fukuda Denshi Co., Ltd. 326
Welch Allyn, Inc. Welch Allyn, Inc. 266
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) Nihon Kohden Corp. 205
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) Nihon Kohden America, Inc. 139
Surveyor Central Mortara Instrument, Inc. 71
Tempus Pro Remote Diagnostic Technologies Ltd. 44
Surveyor S12 Mortara Instrument, Inc. 38
Ultraview Spacelabs Healthcare (Washington), Inc 29
Surveyor S19 Mortara Instrument, Inc. 26
Vital Signs™ AirLife Finland Oy 23
Patient Monitor Edan Instruments, Inc. 22
Telemetry Accessories Philips Medizin Systeme Böblingen GmbH 21

Showing 12 of 589. All products under Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K221056 2023-07-06
K101619 2010-11-12
K053207 2006-05-19
K012226 2002-04-08

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Argus PB-3000
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Schiller AG 510(k) number 2025-08-08 Class II Nonconforming Material/Component Vital sign monitoring instrument may trigger an error message during blood pressures measurements, Specifically, when the initial inflation pressure is set in the high-pressure range. 266 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer