IntelliVue MX400 Patient Monitor
The IntelliVue MX400 patient monitor is operated primarily via touch screen. It has an integrated 9" TFT widescreen touch display and is compatible with the IntelliVue Multi Measurement…
The IntelliVue MX400 patient monitor is operated primarily via touch screen. It has an integrated 9″ TFT widescreen touch display and is compatible with the IntelliVue Multi Measurement Module (M3001A)/ IntelliVue X2 (M3002A) and all Multi-Measurement Module Extensions/ IntelliVue MMX (867036)/ IntelliVue X3 (867030). The IntelliVue MX400 comes with a built-in battery bay as standard (battery not included in base product), built-in comfort handle and integrated power supply in order to make the monitor highly portable.
Who Else Makes It
Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Shenzhen Comen Medical Instruments Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Contec Medical Systems Co., Ltd. | Qinhuangdao | Hebei | Manufacturer | 22 |
| Guangdong Biolight Meditech Co., Ltd. | Zhuhai | Guangdong | Manufacturer | 19 |
| Shanghai Draeger Medical Instrument Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 4 |
| General Meditech, Inc. | Shenzhen | Guangdong | Complaint-file establishment | 3 |
Record
| Listed by | Philips Medizin Systeme Böblingen GmbH, Germany |
|---|---|
| FDA product code | MHX |
| Device type | Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1025 |
| Record published | 2016-09-23 |
| Record revised | 2023-05-05 (version 9) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Storage | Storage environment temperature -20 to 60 °C; Storage environment temperature -4 to 140 °F; Storage environment humidity 5 to 90 % RH; Storage environment atmospheric pressure 57 to 107.5 KiloPascal |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| IntelliVue Patient Monitor MX400 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Fukuda Denshi | Fukuda Denshi Co., Ltd. | 326 |
| Welch Allyn, Inc. | Welch Allyn, Inc. | 266 |
| Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) | Nihon Kohden Corp. | 205 |
| Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) | Nihon Kohden America, Inc. | 139 |
| Surveyor Central | Mortara Instrument, Inc. | 71 |
| Tempus Pro | Remote Diagnostic Technologies Ltd. | 44 |
| Surveyor S12 | Mortara Instrument, Inc. | 38 |
| Ultraview | Spacelabs Healthcare (Washington), Inc | 29 |
| Surveyor S19 | Mortara Instrument, Inc. | 26 |
| Vital Signs™ | AirLife Finland Oy | 23 |
| Patient Monitor | Edan Instruments, Inc. | 22 |
| Telemetry Accessories | Philips Medizin Systeme Böblingen GmbH | 21 |
Showing 12 of 589. All products under Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K251702 | 2025-11-10 |
| K250453 | 2025-09-02 |
| K242962 | 2025-05-05 |
| K221348 | 2023-02-03 |
| K211900 | 2022-03-04 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Philips North America LLC | UDI-DI | 2025-10-31 | Class II | Use error | Potential issue where the IntelliVue monitors did not alarm. | 1,913,441 units |
| Philips North America LLC | UDI-DI | 2025-01-15 | Class II | Software design | Potential failure to alarm for “No Device Data” INOP. The device to alarm after a Hamilton ventilator is disconnected from the EC10 Module or IntelliBridge I/O board. | 28 units |
| Philips North America LLC | UDI-DI | 2024-08-30 | Class II | Nonconforming Material/Component | During a production process, Philips became aware of one IntelliVue power supply with a broken ground bolt upon disconnection of the ground cable from the equipotential ground connector. Loss of electrical grounding may negatively affect th | 545 devices |
| Philips North America LLC | UDI-DI | 2024-06-28 | Class II | Software design | Philips lntelliVue Patient Monitors MX400/450/500/550 Shipped or Upgraded with Incorrect Software Options. Changes were made to reflect some options becoming standard capabilities for software-version N.x. In the process, the entitlements o | 4 units |