Life Scope TR

BSM-6500 Main Unit

Registry build 21.09.26
9manufacturers in China registered for this device type
3catalogue numbers in this listing
11510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MHX
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Shenzhen Comen Medical Instruments Co., Ltd. Shenzhen Guangdong Contract manufacturer 24
Contec Medical Systems Co., Ltd. Qinhuangdao Hebei Manufacturer 22
Guangdong Biolight Meditech Co., Ltd. Zhuhai Guangdong Manufacturer 19
Shanghai Draeger Medical Instrument Co., Ltd. Shanghai Shanghai Contract manufacturer 4
General Meditech, Inc. Shenzhen Guangdong Complaint-file establishment 3

Record

Regulatory record for Life Scope TR
Listed by Nihon Kohden America, Inc., United States
FDA product code MHX
Device type Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
Device class Class 2
Regulation 21 CFR 870.1025
Establishment Repacker / relabeller, Complaint-file establishment, Manufacturer
Record published 2016-09-19
Record revised 2024-04-15 (version 7)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries serial number

Catalogue Numbers

Catalogue numbers for Life Scope TR
Catalogue number Size Status
MU-651RA In distribution
MU-631RA In distribution
MU-671RA In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Fukuda Denshi Fukuda Denshi Co., Ltd. 326
Welch Allyn, Inc. Welch Allyn, Inc. 266
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) Nihon Kohden Corp. 205
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) Nihon Kohden America, Inc. 139
Surveyor Central Mortara Instrument, Inc. 71
Tempus Pro Remote Diagnostic Technologies Ltd. 44
Surveyor S12 Mortara Instrument, Inc. 38
Ultraview Spacelabs Healthcare (Washington), Inc 29
Surveyor S19 Mortara Instrument, Inc. 26
Vital Signs™ AirLife Finland Oy 23
Patient Monitor Edan Instruments, Inc. 22
Telemetry Accessories Philips Medizin Systeme Böblingen GmbH 21

Showing 12 of 589. All products under Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K083271 2008-12-24
K082785 2008-11-26
K073550 2008-03-28
K080342 2008-02-26
K040395 2004-06-01
K030105 2003-03-04
K023475 2002-10-24
K011918 2001-09-12
K001433 2000-11-07
K001693 2000-10-24
K000517 2000-08-31

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-04-29 Class II Software design Due to software issue the device may give false “SpO2 Probe Failure” alarm 16 systems
2017-03-13 Class II Nonconforming Material/Component The Pause function on central monitors will not automatically resume when connected to a Life Scope G9 patient monitor. 654 units total (230 units in US) 2017-10-01
2015-04-14 Class II Under Investigation by firm Nihon Kohden America (NKA) is recalling the Remote Network Station (RNS) 9703 because it may fail to sound. 208 units 2015-10-01
2014-06-03 Class II Software design Software Version 02-26, when used with the Central Nursing Station (CNS) 6201, (PU-621 RA) may unexpectedly and without warning reboot, resulting in a period of approximately 3 minutes during which time the system does not display patient d 430 2015-04-28

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer