OxyTip SpO2

2 catalogue numbers from OXY-FMR-00, listed by GE Healthcare Finland OY, Finland, under Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms). 9 manufacturers in China are registered for this product code.

Registry build 21.09.26
9manufacturers in China registered for this device type
2catalogue numbers in this listing
15510(k) clearances naming this product code
10recalls on this code

Who Else Makes It

Concentrated in Guangdong (6), Jiangsu (1), Hebei (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MHX
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Shenzhen Comen Medical Instruments Co., Ltd. Shenzhen Guangdong Contract manufacturer 24
Contec Medical Systems Co., Ltd. Qinhuangdao Hebei Manufacturer 22
Guangdong Biolight Meditech Co., Ltd. Zhuhai Guangdong Manufacturer 19
Shanghai Draeger Medical Instrument Co., Ltd. Shanghai Shanghai Contract manufacturer 4
General Meditech, Inc. Shenzhen Guangdong Complaint-file establishment 3

Record

Regulatory record for OxyTip SpO2
Listed by GE Healthcare Finland OY, Finland
FDA product code MHX
Device type Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)
Device class Class 2
Regulation 21 CFR 870.1025
Establishment Specification developer, Repacker / relabeller, Manufacturer
510(k) K062324
Record published 2016-06-16
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety MR Safe
Prescription Prescription only
Label carries serial number
Storage Storage environment humidity 5 to 95 % RH; Storage environment temperature -40 to 60 °C

Catalogue Numbers

Catalogue numbers for OxyTip SpO2
Catalogue number Size Status
OXY-FMR-00 In distribution
OXY-WMR-00 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Fukuda Denshi Fukuda Denshi Co., Ltd. 326
Welch Allyn, Inc. Welch Allyn, Inc. 266
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) Nihon Kohden Corp. 205
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms) Nihon Kohden America, Inc. 139
Surveyor Central Mortara Instrument, Inc. 71
Tempus Pro Remote Diagnostic Technologies Ltd. 44
Surveyor S12 Mortara Instrument, Inc. 38
Ultraview Spacelabs Healthcare (Washington), Inc 29
Surveyor S19 Mortara Instrument, Inc. 26
Vital Signs™ AirLife Finland Oy 23
Patient Monitor Edan Instruments, Inc. 22
Telemetry Accessories Philips Medizin Systeme Böblingen GmbH 21

Showing 12 of 589. All products under Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K260656 2026-09-01
K260343 2026-08-28
K223531 2023-04-06
K213363 2022-04-13
K213336 2022-04-13
K213181 2022-04-13
K191323 2020-01-29
K191249 2020-01-24
K191149 2020-01-21
K143676 2015-07-31
K132533 2013-12-04
K131414 2013-08-28
K131223 2013-08-28
K102239 2010-10-18
K092680 2009-09-23

Recalls

10 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-09-26 Class II Component change control Potential loss of monitoring on affected monitors when powered by certain batteries. Affected batteries can lose capability to hold charge and provide back up power. If this situation occurs, it will cause loss of patient monitoring and pot 5935
2025-09-26 Class II Component change control Potential loss of monitoring on affected monitors when powered by certain batteries. Affected batteries can lose capability to hold charge and provide back up power. If this situation occurs, it will cause loss of patient monitoring and pot 2857
2025-09-26 Class II Component change control Potential loss of monitoring on affected monitors when powered by certain batteries. Affected batteries can lose capability to hold charge and provide back up power. If this situation occurs, it will cause loss of patient monitoring and pot 3271
2025-09-26 Class II Component change control Potential loss of monitoring on affected monitors when powered by certain batteries. Affected batteries can lose capability to hold charge and provide back up power. If this situation occurs, it will cause loss of patient monitoring and pot 7408
2025-09-26 Class II Component change control Potential loss of monitoring on affected monitors when powered by certain batteries. Affected batteries can lose capability to hold charge and provide back up power. If this situation occurs, it will cause loss of patient monitoring and pot 5990
2024-04-05 Class II Software design GE HealthCare has become aware of the potential for loss of monitoring on CARESCAPE Canvas 1000, CARESCAPE Canvas Smart Display, and certain versions of CARESCAPE B850 and CARESCAPE B650 monitors if, following the replacement of the CPU tim 25268 units
2024-04-05 Class II Software design GE HealthCare has become aware of the potential for loss of monitoring on CARESCAPE Canvas 1000, CARESCAPE Canvas Smart Display, and certain versions of CARESCAPE B850 and CARESCAPE B650 monitors if, following the replacement of the CPU tim 4649 units
2024-04-05 Class II Software design GE HealthCare has become aware of the potential for loss of monitoring on CARESCAPE Canvas 1000, CARESCAPE Canvas Smart Display, and certain versions of CARESCAPE B850 and CARESCAPE B650 monitors if, following the replacement of the CPU tim 9267 units
2024-04-05 Class II Software design GE HealthCare has become aware of the potential for loss of monitoring on CARESCAPE Canvas 1000, CARESCAPE Canvas Smart Display, and certain versions of CARESCAPE B850 and CARESCAPE B650 monitors if, following the replacement of the CPU tim 54800 units
2024-04-05 Class II Software design GE HealthCare has become aware of the potential for loss of monitoring on CARESCAPE Canvas 1000, CARESCAPE Canvas Smart Display, and certain versions of CARESCAPE B850 and CARESCAPE B650 monitors if, following the replacement of the CPU tim 547 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer