5manufacturers in China registered for this device type
4catalogue numbers in this listing
7510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Shanghai (3), Jiangsu (2). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code NRY
Manufacturer City Province Registered as Device types
Covidien Medical Products (Shanghai) Manufacturing LLC Shanghai Shanghai Contract manufacturer 8
Sterigenics Shanghai ETO Ltd. Shanghai Shanghai Contract manufacturer 65
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Suzhou Zenith Vascular Scitech Limited Suzhou Jiangsu Manufacturer 6
Shanghai Wallaby Medical Technologies Co., Inc. Shanghai Shanghai Contract manufacturer 5

Record

Regulatory record for Zoom Catheter
Listed by Imperative Care Inc., United States
FDA product code NRY
Device type Catheter, Thrombus Retriever
Device class Class 2
Regulation 21 CFR 870.1250
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K211476
Record published 2021-10-18
Record revised 2025-09-24 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Storage Special storage condition: Avoid exposure to water, sunlight, extreme temperatures and high humidity during storage.; Special storage condition: Store in a cool, dry place at room temperature.
Sizes Lumen/inner diameter 0.035 to 0.071 in; outer diameter 0.051 to 0.083 in; catheter length 137 to 160 cm

Catalogue Numbers

Catalogue numbers for Zoom Catheter
Catalogue number Size Status
ICRC071137 Lumen/Inner Diameter 0.071 in In distribution
ICRC045144 Lumen/Inner Diameter 0.045 in In distribution
ICRC055137 Lumen/Inner Diameter 0.055 in In distribution
ICRC035158 Catheter Length 160 cm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Penumbra System Penumbra Inc. 100
RED 43 Penumbra Inc. 18
Solitaire™ X-Pack Micro Therapeutics, Inc. 14
ACE Penumbra Inc. 14
Raptor Aspiration Catheter Balt USA, LLC 13
Cereglide Cerenovus, Inc. 13
Solitaire™ Micro Therapeutics, Inc. 9
Solitaire™ X Micro Therapeutics, Inc. 9
RED 68 Penumbra Inc. 9
Riptide™ Micro Therapeutics, Inc. 9
Zoom™ Reperfusion Catheter Imperative Care Inc. 9
CaptureTM Micro Therapeutics, Inc. 8

Showing 12 of 80. All products under Catheter, Thrombus Retriever

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252046 2025-10-30
K243047 2025-05-28
K242672 2025-01-14
K211476 2021-06-08
K210996 2021-04-23
K202182 2020-09-02
K183043 2019-04-17

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Zoom Catheter
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Imperative Care Inc. 510(k) number 2021-08-13 Class I Under Investigation by firm There is a potential for distal end of catheters to fracture and become detached. 3118 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer