Invos
OxyAlert NIRSensor Cerebral/Somatic - Neonatal;For use with the INVOS (R) 5100C System technology
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (2), Sichuan (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Jiangyin Sinbon Electronics Co Ltd | Jiangyin | Jiangsu | Contract manufacturer | 13 |
| Measurement Specialties Chengdu | Chengdu | Sichuan | Contract manufacturer | 3 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
Record
| Listed by | Covidien LP, United States |
|---|---|
| FDA product code | MUD |
| Device type | Oximeter, Tissue Saturation |
| Device class | Class 2 |
| Regulation | 21 CFR 870.2700 |
| 510(k) | K182868 |
| Record published | 2019-07-31 |
| Record revised | 2026-04-07 (version 16) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Over the counter | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, manufacturing date, serial number |
| Storage | Special storage condition: Keep dry; Storage environment humidity 10 to 95 % RH; Storage environment temperature -4 to 113 °F; Storage environment atmospheric pressure 47 to 108 KiloPascal |
| Packaging | Case of 8, case of 56, pack_or_inner_pack of 10, case of 10, pack_or_inner_pack of 5, case of 2 |
| Distribution end date | 2025-06-06 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| PMAC71RSC | In distribution | |
| PMAC71DOC | Electric Potential,18-19,V; | In distribution |
| DL5100C-US | In distribution | |
| PMSENS71-P | Weight, range 4 to 40, kg; | In distribution |
| PMAC71RSC-L-CH1 | In distribution | |
| PMC71V-SF | In distribution | |
| SPFB/USA | Patient Weight,< 40,Kilogram; | In distribution |
| 5100C-PB-OEM | In distribution | |
| PMVAC-AFTD101P | In distribution | |
| 5100C-US | In distribution | |
| PMAC71RIC | In distribution | |
| SAFB-SM/INTL | Patient Weight,> 40,Kilogram; | In distribution |
| PMPAMP71 | In distribution | |
| CNN/SNN | Patient Weight, < 5,Kilogram; | In distribution |
| SPFB/INTL20 | Patient Weight,< 40,Kilogram; | In distribution |
| PM7100 | Electric Potential,18,V; | In distribution |
| PMC71V-GE | In distribution | |
| RSC-3 | In distribution | |
| PM7100 | In distribution | |
| PMSENS71-A | Patient weight, >40, KG; | In distribution |
| 5100C-PA | In distribution | |
| PMPAMP71 | In distribution | |
| 5100C-JP | In distribution | |
| SAFB-SM/INTL20 | Patient Weight,> 40,Kilogram; | In distribution |
| PMAC71DOC | In distribution | |
| PMSENS71-A | Patient weight, >40, KG; | In distribution |
| 5100C-PB | In distribution | |
| PMAC71RSC-L-CH3 | In distribution | |
| RSC-2 | In distribution | |
| DL5100C-PB | In distribution | |
| DLPMPAMP71 | In distribution | |
| SAFB-SM/USA | Patient Weight,> 40,Kilogram; | In distribution |
| SPFB/INTL | Patient Weight,< 40,Kilogram; | In distribution |
| CNN | Patient Weight,< 5,Kilogram; | In distribution |
| PMVAC-AFTD101A | In distribution | |
| SNN | Patient Weight,< 5,Kilogram; | In distribution |
| 5100C-EU | In distribution | |
| PMAC71RSC-L-CH4 | In distribution | |
| IS | Patient Weight, < 40, kg; | In distribution |
| CNN/SNN | Weight, less than 5, kg; | In distribution |
| PM7100 | In distribution | |
| PMC71VP-GE | In distribution | |
| IS | Patient Weight, less than 40, kg only; | In distribution |
| 5100C-PA-OEM | In distribution | |
| PMPAMP71 | In distribution | |
| DL5100C-PA | In distribution | |
| RSC-4 | In distribution | |
| PMAC71RSC-L-CH2 | In distribution | |
| RSC-1 | In distribution | |
| DS5100C-PB | Withdrawn | |
| DS5100C-PA | Withdrawn | |
| DS5100C-US | Withdrawn | |
| IS-S | Patient Weight; < 40 kg; | Withdrawn |
| IS-C | Patient Weight, < 40, kg; | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Nonin | Nonin Medical, Inc. | 30 |
| Fore-Sight Elite® | Cas Medical Systems, Inc. | 12 |
| Fore-Sight® | Cas Medical Systems, Inc. | 9 |
| ForeSight | Edwards Lifesciences Technology Sarl | 7 |
| Spectros T-Stat | Spectros Corporation | 7 |
| Component Neuromonitoring System | Moberg Research, Inc. | 6 |
| HyperView | Hypermed Imaging, Inc. | 6 |
| O3 | Masimo Corporation | 5 |
| Mespere | Mespere Lifesciences Inc. | 3 |
| SnapshotNIR | Kent Imaging Inc | 2 |
| Moor Instruments Ltd | Moor Instruments Ltd. | 2 |
| T.Ox SS Sensor | Vioptix, Inc. | 1 |
Showing 12 of 30. All products under Oximeter, Tissue Saturation
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Covidien | 510(k) number | 2024-01-09 | Class II | Process design | manufacturing defects to sensor cable connectors may result in error codes or non-functioning channel | 1122 units |
| Covidien | 510(k) number | 2024-01-09 | Class II | Process design | manufacturing defects to sensor cable connectors may result in error codes or non-functioning channel | 2305 units |