Nonin

Non-Adhesive, Single-Patient Use, Non-Sterile, Disposable Regional Oximetry Sensor with EQUANOX™ Technology

Registry build 21.09.26
5manufacturers in China registered for this device type
30catalogue numbers in this listing
5510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Sichuan (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MUD
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Jiangyin Sinbon Electronics Co Ltd Jiangyin Jiangsu Contract manufacturer 13
Measurement Specialties Chengdu Chengdu Sichuan Contract manufacturer 3
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57

Record

Regulatory record for Nonin
Listed by Nonin Medical, Inc., United States
FDA product code MUD
Device type Oximeter, Tissue Saturation
Device class Class 2
Regulation 21 CFR 870.2700
Establishment Contract manufacturer, Specification developer, Manufacturer
510(k) K090807
Record published 2016-08-24
Record revised 2020-12-01 (version 5)

Specifications

Specifications
MRI safety MR Unsafe
Single use Yes
Prescription Prescription only
Latex Contains natural rubber latex
Label carries lot or batch number, expiry date, manufacturing date, serial number
Storage Storage environment temperature -22 to 158 °F; Storage environment temperature -30 to 70 °C
Packaging Box, bag, box of 20, box of 10, pack of 10

Catalogue Numbers

Catalogue numbers for Nonin
Catalogue number Size Status
X-100SP-2 In distribution
7600 In distribution
7600PA INT C Lock In distribution
X-100SP-5 In distribution
X-100SP-1 In distribution
X-100SP-3 In distribution
8204CA Pediatric In distribution
X-100HH In distribution
INT-100 In distribution
7600TC-3 In distribution
7600TC-2A In distribution
8004CB-NA Neonate In distribution
INT-2XX Pediatric In distribution
8000CA Adult In distribution
7600TC-3 In distribution
8003CA Adult In distribution
8003CA Adult In distribution
8004CB Neonate In distribution
7600 In distribution
X-100 In distribution
8004CA In distribution
7600TC-2 In distribution
X-100H In distribution
X-100SP-4 In distribution
7600PA Sensor Lock In distribution
7600 TC-1 In distribution
7600PA In distribution
7600 In distribution
X-100SP-6 In distribution
Sense PMC In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Invos Covidien LP 54
Fore-Sight Elite® Cas Medical Systems, Inc. 12
Fore-Sight® Cas Medical Systems, Inc. 9
ForeSight Edwards Lifesciences Technology Sarl 7
Spectros T-Stat Spectros Corporation 7
Component Neuromonitoring System Moberg Research, Inc. 6
HyperView Hypermed Imaging, Inc. 6
O3 Masimo Corporation 5
Mespere Mespere Lifesciences Inc. 3
SnapshotNIR Kent Imaging Inc 2
Moor Instruments Ltd Moor Instruments Ltd. 2
T.Ox SS Sensor Vioptix, Inc. 1

Showing 12 of 30. All products under Oximeter, Tissue Saturation

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K190560 2019-05-02
K151305 2015-08-27
K113215 2012-05-14
K102715 2010-12-17
K090807 2009-06-30

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Nonin
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Nonin Medical, Inc. 510(k) number 2014-11-25 Class II Nonconforming Material/Component Nonin Medical is conducting a recall of certain
regional oximetry sensors and associated products. They have received reports of signal loss during use of our shortcabled regional oximetry sensors with diaphoretic patients. No injury or il
5892 (5452 US, 440 OUS) 2015-09-01
Nonin Medical, Inc. 510(k) number 2009-10-23 Not classified Device Design A malfunction was detected with one of the components that, under rare circumstances, may result in the overheating of the POD. This overheating, while unlikely to occur, has the potential to cause a burn if the POD is in direct contact wi 62 2012-03-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer