Retracta

Retracta Detachable Embolization Coil

Registry build 21.09.26
6manufacturers in China registered for this device type
18catalogue numbers in this listing
13510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (4), Guangdong (1), Shanghai (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code KRD
Manufacturer City Province Registered as Device types
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24
Suzhou Prosteri Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 20
Canyon Medical Inc. Nanjing Jiangsu Manufacturer 4
Suzhou Hengrui Hongyuan Medical Co., Ltd. Suzhou Jiangsu Manufacturer 3
Microport Neurotech (Shanghai) Co., Ltd. Shanghai Shanghai Manufacturer 2
Suzhou Haowei Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 1

Record

Regulatory record for Retracta
Listed by Cook Incorporated, United States
FDA product code KRD
Device type Device, Vascular, For Promoting Embolization
Device class Class 2
Regulation 21 CFR 870.3300
Establishment Contract manufacturer, Contract steriliser, Specification developer, Complaint-file establishment, Manufacturer, Exporter
Record published 2015-10-24
Record revised 2021-02-05 (version 3)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: Store in dark, dry, cool place.

Catalogue Numbers

Catalogue numbers for Retracta
Catalogue number Size Status
G34190 In distribution
G34189 In distribution
G34203 In distribution
G34200 In distribution
G34191 In distribution
G34199 In distribution
G34204 In distribution
G34193 In distribution
G34197 In distribution
G34198 In distribution
G34194 In distribution
G34188 In distribution
G34195 In distribution
G34192 In distribution
G34196 In distribution
G34202 In distribution
G34201 In distribution
G34187 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Prestige Coil System Balt USA, LLC 339
Axium™ Detachable Coil System Micro Therapeutics, Inc. 279
Optima Coil System Balt USA, LLC 255
AxiumTM Micro Therapeutics, Inc. 255
Avenir Shanghai Wallaby Medical Technologies Co., Inc. 184
MReye Cook Incorporated 167
Axium™ Prime Detachable Coil System Micro Therapeutics, Inc. 162
Nester Cook Incorporated 160
Axium Micro Therapeutics, Inc. 146
ConcertoTM Micro Therapeutics, Inc. 133
Tornado Cook Incorporated 111
V-Trak MicroVention, Inc. 105

Showing 12 of 158. All products under Device, Vascular, For Promoting Embolization

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K160219 2016-08-03
K153778 2016-05-19
K150931 2015-12-18
K150964 2015-12-18
K151676 2015-07-22
K123712 2013-01-03
K090624 2009-04-02
K063619 2006-12-20
K052834 2005-11-23
K993455 2000-01-11
K992121 1999-12-20
K940189 1994-11-28
K940982 1994-10-14

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-04-17 Class II Process control Cook Medical identified that devices from the affected device lots may contain the incorrectly sized embolization coil. 2952 units
2022-05-05 Class II Under Investigation by firm The loading cartridges included with these devices may contain a small, unintended, stainless-steel cannula. 106,033
2022-05-05 Class II Under Investigation by firm The loading cartridges included with these devices may contain a small, unintended, stainless-steel cannula. 106,033
2022-05-05 Class II Under Investigation by firm The loading cartridges included with these devices may contain a small, unintended, stainless-steel cannula. 106,033
2005-09-26 Not classified Other The coil is 20 centimeters in length, but the label states the length is 20 millimeters. 242 2006-01-10

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P780011 1988-01-29 MINI BALLOON Bd Becton Dickinson Vacutainer Systems Preanalytic

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker