Standard Hard Paddles

Paddle Assy-Detachable,rohs,eng

Registry build 21.09.26
3manufacturers in China registered for this device type
1catalogue number
17510(k) clearances naming this product code
21recalls on this code

Who Else Makes It

All of them in Guangdong. 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LDD
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24
EMI (Dongguan) Asia Limited Dongguan Guangdong Contract manufacturer 9

Record

Regulatory record for Standard Hard Paddles
Listed by Physio-Control, Inc., United States
FDA product code LDD
Device type Dc-Defibrillator, Low-Energy, (Including Paddles)
Device class Class 2
Regulation 21 CFR 870.5300
Establishment Specification developer, Complaint-file establishment, Manufacturer
Record published 2019-04-15
Record revised 2023-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Standard Hard Paddles
Catalogue number Size Status
11130 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Unipower Unipower Corp. 623
Internal Handle Zoll Medical Corporation 89
Vermed Nissha Medical Technologies Limited 47
Cardio Clear Cardio Medical Products, Inc. 33
Dc-Defibrillator, Low-Energy, (Including Paddles) Fiab SPA 20
Dc-Defibrillator, Low-Energy, (Including Paddles) Physio-Control, Inc. 20
R2 ConMed Corporation 17
HeartStart Philips Medical Systems Hsg 9
Anybattery Anybattery, Inc 6
Tempus LS-Manual Remote Diagnostic Technologies Ltd. 6
Vermed Defib Pads Graphic Controls Acquisition Corporation 5
HeartStart Philips Electronics North America Corporation 4

Showing 12 of 29. All products under Dc-Defibrillator, Low-Energy, (Including Paddles)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K182503 2019-06-03
K922315 1994-03-16
K935674 1993-12-16
K931053 1993-05-18
K912966 1992-02-21
K910144 1991-07-17
K902288 1991-02-25
K905510 1990-12-20
K902478 1990-10-31
K895379 1990-02-26
K890079 1989-02-23
K883617 1988-12-28
K881153 1988-07-27
K871224 1987-05-20
K832833 1984-10-26
K842624 1984-10-18
K843229 1984-10-18

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-08-09 Class II Under Investigation by firm Due to customer complaints and out of box failures, the firm is conducting a voluntary recall as a result of product failures (cracks and over-molding separation of the sterilizable internal defibrillation paddles. 3,617 devices (US-3315 and O.U.S – 302 devices)
2009-02-16 Not classified Other Sterilization efficacy can not be confirmed for the current methods of sterilization listed in the product labeling. TOTAL: 3218 units; 2052 in the US, 1166 internationally 2011-08-17
2008-12-30 Not classified Employee error When users do not disconnect the test plug and reconnect the QUIK-COMBO electrodes to the therapy cable, the test plug signal can be misinterpreted as a patient waveform. 23,467 units worldwide 2011-11-21
2008-11-17 Not classified Labeling False and Misleading Sterilization efficacy could not be confirmed for sterilization methods on External Sterilizable Paddles and Pediatric Paddle attachments. 1689 units 2010-09-28
2008-11-17 Not classified Labeling False and Misleading Sterilization efficacy could not be confirmed for sterilization methods on External Sterilizable Paddles and Pediatric Paddle attachments. 38,185 units 2010-09-28
2008-05-13 Not classified Device Design A thicker keypad that may prevent the door from fully latching closed. If the door is not fully closed, there is a potential that the defibrillator will not automatically change from automatic external defibrillation (AED) mode to manual mo 24 units 2011-03-20
2008-05-13 Not classified Device Design A thicker keypad may prevent the door from fully latching closed. If the door is not fully closed, there is a potential that the defibrillator will not automatically change from automatic external defibrillation (AED) mode to manual mode by 1,219 units 2011-03-20
2008-05-13 Not classified Device Design A thicker keypad that may prevent the door from fully latching closed. If the door is not fully closed, there is a potential that the defibrillator will not automatically change from automatic external defibrillation (AED) mode to manual mo 78 keypads 2011-03-20
2008-04-16 Not classified Software design The LIFEPAK 20e defibrillator / monitors with software versions 058 have an increase in likelihood for an incorrect Shock Advisory Algorithm (SAS) decision if the Auto Analyze setting in AED mode is On, leading to incorrectly render of shoc 969 units 2011-03-29
2008-04-16 Not classified Software design The LIFEPAK 20 defibrillator / monitors with software versions 048, 052 and 054 have an increase in likelihood for an incorrect Shock Advisory Algorithm (SAS) decision if the Auto Analyze setting in AED mode is On, leading to incorrectly re 21,102 units 2011-03-29
2008-04-16 Not classified Software design The LIFEPAK 12 defibrillator / monitors with software version 130 have an increase in likelihood for an incorrect Shock Advisory Algorithm (SAS) decision if the Auto Analyze setting in AED mode is On, leading to incorrectly render of shock 19,805 units 2011-03-29
2008-01-29 Not classified Labeling design Based on testing, sterilization methods described in labeling may be ineffective and may cause damage or corrosion to the paddles or handles. If handles and/or paddles are not sterilized adequately and are used on a patient, there is a ris 2011-05-04
2008-01-29 Not classified Labeling design Based on testing, sterilization methods described in labeling may be ineffective and may cause damage or corrosion to the paddles or handles. If handles and/or paddles are not sterilized adequately and are used on a patient, there is a ri 47,274 worlwide for Defibrillator Handles and Paddles 2011-05-04
2006-08-30 Not classified Other Devices with v38 system software do not display a ”LOW BATTERY: CONNECT TO AC POWER” message when the monitor is on backup (DC) battery power and may shut down without warning. 2,831 worldwide 2011-03-25
2006-03-22 Not classified Nonconforming Material/Component Therapy connectors may have connector sockets that do not meet design specs – short drill depth. Interruption of the connections may cause unexpected, intermittent or complete loss of pacing and defibrillation functions. 2678 devices 2011-09-06
2006-03-16 Not classified Other LIFEPAK 20 may lock-up when attempting to power-up on DC within 2 seconds after removing AC power. 10,307 devices as of 9-19-06 2011-03-29
2005-09-02 Not classified Other Potential for voltage pins in connector of therapy cable to break. 2011-01-17
2005-09-02 Not classified Other Potential for voltage pins in connector of therapy cable to break. total for both types – 52,654 2011-01-17
2005-06-17 Not classified Other The defibrillator may not operate if the device is turned on during an AC Loss Alert. 3924 units 2006-05-06
2004-05-05 Not classified Other The DC Power Adapter may fail to charge LIFEPAK NiCd 2.4 AH batteries used with the LIFEPAK 12 defibrillator/monitor. 1689 2005-01-06
2004-04-05 Not classified Other Potential for display to go blank due to an electrical component that may fail due to mechanical shock of vibration of the defibrillator. 2885 2005-01-06

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer