Atellica CH Trig

Triglycerides (Trig) Atellica CH - RGT 2000T

Registry build 21.09.26
2manufacturers in China registered for this device type
1catalogue number
1510(k) clearance
8recalls on this code

Who Else Makes It

Concentrated in Shandong (1), Zhejiang (1).

Chinese manufacturers registered for FDA product code CDT
Manufacturer City Province Registered as Device types
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70
Hangzhou Lysun Biotechnology Co., Ltd. Hangzhou Zhejiang Manufacturer 22

Record

Regulatory record for Atellica CH Trig
Listed by Siemens Healthcare Diagnostics Inc, United States
FDA product code CDT
Device type Lipase Hydrolysis/Glycerol Kinase Enzyme, Triglycerides
Device class Class 1
Regulation 21 CFR 862.1705
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K133067
Record published 2017-12-22
Record revised 2024-03-07 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries lot or batch number, expiry date
Storage Special storage condition: Protect From Light; Storage environment temperature 2 to 8 °C
Distribution end date 2024-03-01

Catalogue Numbers

Catalogue numbers for Atellica CH Trig
Catalogue number Size Per pack Status
11097591 4 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Biobase Biobase Biodustry(Shandong)Co., Ltd. 20
JAS Diagnostics Drew Scientific, Ltd. 8
Pointe Scientific, Inc. Horiba Instruments Incorporated 7
Synermed® Infrared Laboratory Systems LLC 6
AU Beckman Coulter, Inc. 5
Triglycerides Roche Diagnostics Gmbh 4
Triglycerides (Trigs) Randox Laboratories Limited 4
Carolina Liquid Chemistries Corp.® Triglycerides Reagent KIT DT213 Carolina Liquid Chemistries 4
Vitros Ortho-Clinical Diagnostics, Inc. 3
Teco Diagnostics Triglyceride – GPO Liquid Reagent Set Teco Diagnostics 3
Triglycerides/Glycerol Blanked Roche Diagnostics Gmbh 2
Triglyceride-SL Sekisui Diagnostics, LLC 2

Showing 12 of 48. All products under Lipase Hydrolysis/Glycerol Kinase Enzyme, Triglycerides

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K133067 2013-11-22

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Atellica CH Trig
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Siemens Healthcare Diagnostics Inc 510(k) number 2023-01-27 Class II Under Investigation by firm Reagent Carryover from LDL Cholesterol Direct (DLDL), Total Protein II (TP), Triglycerides (Trig), and Triglycerides_2 (Trig_2) Impacting Magnesium (Mg) Results 11824 units
Siemens Healthcare Diagnostics Inc 510(k) number 2016-03-17 Class II Device Design Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyrone) interference with Trinder and Trinder-like reaction assays. Siemens has confirmed that falsely depressed results may occur on samples drawn 137422 units total 2017-09-25
Siemens Healthcare Diagnostics Inc 510(k) number 2016-03-07 Class II Under Investigation by firm Siemens Healthcare Diagnostics has confirmed the ADVIA Chemistry Triglyceride concentrated reagent (TRIG_c) does not meet Instructions For Use (IFU) linearity claims at the upper limit of the assay range as it approaches end of shelf life f 7,433 units (4,228 for lot 348297 and 3,199 for lot # 359932 2017-12-01

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2023-01-27 Class II Under Investigation by firm Reagent Carryover from LDL Cholesterol Direct (DLDL), Total Protein II (TP), Triglycerides (Trig), and Triglycerides_2 (Trig_2) Impacting Magnesium (Mg) Results 5315 units
2021-10-06 Class II Software design The Aptio Automation Firmware for the ADVIA Centaur XP/XPT Interface Module may lead, in some cases, to an incorrect association of test results to sample ID. Incorrect association of test results could impact clinical interpretations and c 1142
2016-03-17 Class II Device Design Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyrone) interference with Trinder and Trinder-like reaction assays. Siemens has confirmed that falsely depressed results may occur on samples drawn 137422 units total 2017-09-25
2016-03-17 Class II Device Design Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyrone) interference with Trinder and Trinder-like reaction assays. Siemens has confirmed that falsely depressed results may occur on samples drawn 137422 units total 2017-09-25
2009-09-01 Not classified Software design Incorrect result: An intermittent low result may be seen with the last test run from an aliquot on a Dimension Vista System when connected to a StreamLAB Analytical Workcell. The sample delivery sequence may deliver insufficient surplus v 81 units 2010-09-15

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer