Pointe Scientific, Inc. Triglyceride
Pointe Scientific, Inc. Triglyceride Reagent is for the in vitro quantitative determination of Triglycerides in serum or plasma. Packaged for use on Olympus Analyzers. 12 x 65ml
Who Else Makes It
Concentrated in Shandong (1), Zhejiang (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Biobase Biodustry(Shandong)Co., Ltd. | Jinan | Shandong | Manufacturer | 70 |
| Hangzhou Lysun Biotechnology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 22 |
Record
| Listed by | Horiba Instruments Incorporated, United States |
|---|---|
| FDA product code | CDT |
| Device type | Lipase Hydrolysis/Glycerol Kinase Enzyme, Triglycerides |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1705 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K862033 |
| Record published | 2016-08-31 |
| Record revised | 2025-10-02 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| OT932-780 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Biobase | Biobase Biodustry(Shandong)Co., Ltd. | 20 |
| JAS Diagnostics | Drew Scientific, Ltd. | 8 |
| Pointe Scientific, Inc. | Horiba Instruments Incorporated | 7 |
| Synermed® | Infrared Laboratory Systems LLC | 6 |
| AU | Beckman Coulter, Inc. | 5 |
| Triglycerides | Roche Diagnostics Gmbh | 4 |
| Triglycerides (Trigs) | Randox Laboratories Limited | 4 |
| Carolina Liquid Chemistries Corp.® Triglycerides Reagent KIT DT213 | Carolina Liquid Chemistries | 4 |
| Vitros | Ortho-Clinical Diagnostics, Inc. | 3 |
| Teco Diagnostics Triglyceride – GPO Liquid Reagent Set | Teco Diagnostics | 3 |
| Triglycerides/Glycerol Blanked | Roche Diagnostics Gmbh | 2 |
| Triglyceride-SL | Sekisui Diagnostics, LLC | 2 |
Showing 12 of 48. All products under Lipase Hydrolysis/Glycerol Kinase Enzyme, Triglycerides
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2016-01-11 | Class II | Under Investigation by firm | N-Acetylcysteine (NAC) present in the blood of patients treated for paracetamol overdose can interfere with the Trinder reaction that uses hydrogen peroxide catalytic on aminoantipyrine and phenol, and can produce falsely low results with t | 216 | 2016-06-07 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.