Membrane for E722 Electrode

D722 K membrane box (4 units) for ABL7XX/8XX

Registry build 21.09.26
2manufacturers in China registered for this device type
1catalogue number
1510(k) clearance
3recalls on this code

Who Else Makes It

All of them in Guangdong.

Chinese manufacturers registered for FDA product code CEM
Manufacturer City Province Registered as Device types
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56

Record

Regulatory record for Membrane for E722 electrode
Listed by Radiometer Medical APS, Denmark
FDA product code CEM
Device type Electrode, Ion Specific, Potassium
Device class Class 2
Regulation 21 CFR 862.1600
Establishment Complaint-file establishment, Manufacturer
Record published 2016-09-01
Record revised 2020-11-27 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, expiry date
Storage Storage environment temperature 2 to 32 °C

Catalogue Numbers

Catalogue numbers for Membrane for E722 electrode
Catalogue number Size Per pack Status
942-059 4 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Nova Nova Biomedical Corporation 8
Stat Profile Nova Biomedical Corporation 7
Potassium electrode Roche Diagnostics Gmbh 4
Potassium Electrode Diamond Diagnostics Inc. 3
Synermed® Infrared Laboratory Systems LLC 3
Architect Abbott Laboratories 3
Phoenix Diagnostics, Inc. Phoenix Diagnostics, Inc. 2
I.S.E. K Randox Laboratories Limited 2
Pointe Scientific, Inc. Horiba Instruments Incorporated 2
Potassium Electrode Medica Corp. 2
Na/K Solution Pack Medica Corp. 2
Selectra VitalScientific B.V. 2

Showing 12 of 93. All products under Electrode, Ion Specific, Potassium

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K092686 2010-08-06

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-04-14 Class II Device Design Due to an issue with the internal clock of the analyzers with an e3800 PC unit installed. Total 965 PC units World-wide (only 35 units in the U.S.)
2021-04-14 Class II Device Design Due to an issue with the internal clock of the analyzers with an e3800 PC unit installed. Total=3,346 analyzers world-wide (only 2 analyzers within th
2020-02-03 Class II Software design The firm received reports of occurrences where the barcode reader misinterpreted the contents of a locally printed barcode label used for entering patient ID or accession number into the analyzer in connection with a sample measurement. T 12,822 units 2022-09-20

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer