RAPIDSystems™ AutomaticQC Cartridge

for in vitro diagnostic use for multi-level quality control of RAPIDPoint® 400 system only.

Registry build 21.09.26
2manufacturers in China registered for this device type
1catalogue number
2recalls on this code

Who Else Makes It

All of them in Guangdong.

Chinese manufacturers registered for FDA product code CEM
Manufacturer City Province Registered as Device types
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56

Record

Regulatory record for RAPIDSystems™ AutomaticQC Cartridge
Listed by Siemens Healthcare Diagnostics Inc, United States
FDA product code CEM
Device type Electrode, Ion Specific, Potassium
Device class Class 2
Regulation 21 CFR 862.1600
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K002738
Record published 2017-01-23
Record revised 2021-11-19 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries lot or batch number, expiry date, serial number
Storage Handling environment temperature 2 to 25 °C; Storage environment temperature 2 to 8 °C

Catalogue Numbers

Catalogue numbers for RAPIDSystems™ AutomaticQC Cartridge
Catalogue number Size Status
11046781 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Nova Nova Biomedical Corporation 8
Stat Profile Nova Biomedical Corporation 7
Potassium electrode Roche Diagnostics Gmbh 4
Potassium Electrode Diamond Diagnostics Inc. 3
Synermed® Infrared Laboratory Systems LLC 3
Architect Abbott Laboratories 3
Phoenix Diagnostics, Inc. Phoenix Diagnostics, Inc. 2
I.S.E. K Randox Laboratories Limited 2
Pointe Scientific, Inc. Horiba Instruments Incorporated 2
Potassium Electrode Medica Corp. 2
Na/K Solution Pack Medica Corp. 2
Selectra VitalScientific B.V. 2

Showing 12 of 93. All products under Electrode, Ion Specific, Potassium

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of RAPIDSystems™ AutomaticQC Cartridge
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Siemens Healthcare Diagnostics Inc 510(k) number 2025-06-26 Class II Under Investigation by firm Siemens Healthcare Diagnostics is recalling the RAPIDPoint 500 Systems Wash/Waste Cartridge Lot WW/08925 due to a manufacturing error causing positive and negative bias in Ionized Calcium, Potassium, pH, Chloride, pCO2, Glucose and Lactate 1,477 units
Siemens Healthcare Diagnostics Inc 510(k) number 2016-08-11 Class II Software design There is a potential for the first and/or last name of one patient to be printed with Patient ID and result data from a different patient, even though those fields have been turned Off for the system 492 units 2020-07-16
Siemens Healthcare Diagnostics Inc 510(k) number 2012-09-17 Class II Software Manufacturing/Software Deployment RAPIDPoint 400 Series, RAPIDPoint 500, or
RAPIDLab 1200 Series blood gas analyzer, users can inadvertently enter a wrong patient ID on the demographics screen, which ultimately could lead to a misidentification of the sample
828 units 2015-04-01
Siemens Healthcare Diagnostics Inc 510(k) number 2009-10-30 Not classified Component design/selection Software: Reference sensor failure may result in inaccurate pH reuslts 998 units 2015-09-04
Siemens Healthcare Diagnostics Inc 510(k) number 2009-10-30 Not classified Component design/selection Software: Reference sensor failure may result in inaccurate pH reuslts 4095 units 2015-09-04

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-02-24 Class II Under Investigation by firm A positive bias beyond 5% resulting in a dilution check failure or an unnecessary dilution check correction if the positive bias is greater than 1% and less than 5%. The dilution check correction would be detected by QC; however, if not det 5981 2017-02-01
2010-08-19 Not classified Other High potassium content in the affected lots results in the potential for low potassium recovery for Dilution Check, QC and patient samples when run on the Dimension Vista System. 3,706 cartons 2010-10-26

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.