eGLU, 15ct., CCPlus Home
Catalogue number REF 4755, listed by Polymer Technology Systems, United States, under Glucose Oxidase, Glucose. 8 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (3), Zhejiang (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Flextronics Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Yasee Biomedical Inc | Qingdao | Shandong | Contract manufacturer | 5 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
| Shenzhen Yuwen E-Commerce Co., Ltd. | Shenzhen | Guangdong | Repacker / relabeller | 19 |
| Tianjin Empecs Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 8 |
Record
| Listed by | Polymer Technology Systems, United States |
|---|---|
| FDA product code | CGA |
| Device type | Glucose Oxidase, Glucose |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1345 |
| Establishment | Complaint-file establishment, Manufacturer |
| 510(k) | K140068 |
| Record published | 2023-06-20 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Over the counter | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Keep away from sunlight Keep dry; Storage environment temperature 68 to 86 °F; Storage environment temperature 20 to 30 °C |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| REF 4755 | 15 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| i-STAT | Abbott Point OF Care Inc. | 48 |
| YSI Incorporated | YSI Incorporated | 34 |
| Auvon | Shenzhen Yuwen E-Commerce Co., Ltd. | 28 |
| Stat Profile | Nova Biomedical Corporation | 17 |
| Fora | Fora Care Inc. | 13 |
| TRUEtrack | Trividia Health, Inc. | 12 |
| JAS Diagnostics | Drew Scientific, Ltd. | 11 |
| StatStrip | Nova Biomedical Corporation | 9 |
| Gluc-PAP | Randox Laboratories Limited | 8 |
| Nova Primary | Nova Biomedical Corporation | 8 |
| Synermed® | Infrared Laboratory Systems LLC | 7 |
| Prodigy No Coding Blood Glucose Test Strips | Prodigy Diabetes Care, LLC | 7 |
Showing 12 of 215. All products under Glucose Oxidase, Glucose
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K151530 | 2015-07-07 |
| K142302 | 2014-10-02 |
| K013068 | 2001-11-20 |
| K972669 | 1998-01-22 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Polymer Technology Systems | 510(k) number | 2019-12-02 | Class II | Device Design | One brand of batteries have a small dimensional difference in the negative button terminal, which, when the batteries are inserted incorrectly, can create the possibility for the battery terminals to make reverse contact. This reverse cont | 44,448 total | 2020-07-06 |
| Polymer Technology Systems | 510(k) number | 2019-12-02 | Class II | Device Design | One brand of batteries have a small dimensional difference in the negative button terminal, which, when the batteries are inserted incorrectly, can create the possibility for the battery terminals to make reverse contact. This reverse cont | 44,448 total | 2020-07-06 |
| Polymer Technology Systems | 510(k) number | 2019-12-02 | Class II | Device Design | One brand of batteries have a small dimensional difference in the negative button terminal, which, when the batteries are inserted incorrectly, can create the possibility for the battery terminals to make reverse contact. This reverse cont | 44,448 | 2020-07-06 |
| Polymer Technology Systems | 510(k) number | 2019-12-02 | Class II | Device Design | One brand of batteries have a small dimensional difference in the negative button terminal, which, when the batteries are inserted incorrectly, can create the possibility for the battery terminals to make reverse contact. This reverse cont | 44,448 total | 2020-07-06 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-08-16 | Class III | Labeling Change Control | Incorrect instructions for use were packaged into the final product. | ||
| 2019-01-16 | Class II | Device Design | Some lots of test strips do not fit tightly into the optical block, and may fall out during analysis, which could lead to an incorrect result being displayed | 67643 total | 2020-06-24 |
| 2009-08-04 | Not classified | Other | Possible under recovery of cholesterol, HDL and glucose. A loss of recoverable cholesterol and HDL cholesterol is a manageable to moderate health risk. The clinical applications analysis shows that lot 1891 shows such a loss of activity. A | 962 | 2010-10-20 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P990026 | 2002-02-04 | CYGNUS GLUCOWATCH AUTOMATIC GLUCOSE BIOGRAPHER | Animas Corp. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.