HemoCue® Glucose 201 Analyzer
HemoCue Glucose 201 Analyzer mmol/L whole blood
Who Else Makes It
Concentrated in Guangdong (3), Zhejiang (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Flextronics Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Yasee Biomedical Inc | Qingdao | Shandong | Contract manufacturer | 5 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
| Shenzhen Yuwen E-Commerce Co., Ltd. | Shenzhen | Guangdong | Repacker / relabeller | 19 |
| Tianjin Empecs Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 8 |
Record
| Listed by | Hemocue AB, Sweden |
|---|---|
| FDA product code | CGA |
| Device type | Glucose Oxidase, Glucose |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1345 |
| Establishment | Manufacturer |
| 510(k) | K020935 |
| Record published | 2016-05-31 |
| Record revised | 2022-10-31 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Storage | Storage environment temperature 0 to 50 °C; Storage environment temperature 32 to 122 °F |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 120707 | In distribution | |
| 120706 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| i-STAT | Abbott Point OF Care Inc. | 48 |
| YSI Incorporated | YSI Incorporated | 34 |
| Auvon | Shenzhen Yuwen E-Commerce Co., Ltd. | 28 |
| Stat Profile | Nova Biomedical Corporation | 17 |
| Fora | Fora Care Inc. | 13 |
| TRUEtrack | Trividia Health, Inc. | 12 |
| JAS Diagnostics | Drew Scientific, Ltd. | 11 |
| StatStrip | Nova Biomedical Corporation | 9 |
| Gluc-PAP | Randox Laboratories Limited | 8 |
| Nova Primary | Nova Biomedical Corporation | 8 |
| Synermed® | Infrared Laboratory Systems LLC | 7 |
| Prodigy No Coding Blood Glucose Test Strips | Prodigy Diabetes Care, LLC | 7 |
Showing 12 of 215. All products under Glucose Oxidase, Glucose
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K020935 | 2002-04-03 |
| K943432 | 1995-01-17 |
| K911141 | 1991-05-08 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Hemocue AB | 510(k) number | 2025-05-12 | Class II | Storage | Glucose microcuvettes experienced transit time outside of limits, so stability through the whole microcuvette lifetime can no longer be guaranteed. The affected products may not have been stored at the recommended labeled storage conditions | 4 Boxes | |
| Radiometer America, Inc. | 510(k) number | 2014-10-20 | Class II | Under Investigation by firm | Batches of HemoCue Glucose 201 Microcuvettes show discoloration and provide results outside the specification at the end of their shelf life, approx. after 6 months. The HemoCue Glucose 201 Analyzer with plasma conversion multiplies the me | 3,712,900 microcuvettes | 2015-10-02 |
| Hemocue AB | 510(k) number | 2013-07-15 | Class II | Packaging | During a complaint investigation HemoCue AB discovered punctured HemoCue Glucose 201 single pack pouches. | 22,215 boxes of 100 cuvettes distributed in US, 34, 841 dist | 2014-09-02 |
| Hemo Cue, Inc. | 510(k) number | 2011-05-30 | Not classified | Packaging process control | A recall was initiated because Hemocue confirmed that the package insert for Hemocue Glucose 201 Microcuvettes had errors in two sections. | 13,620 packages | 2012-03-02 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P990026 | 2002-02-04 | CYGNUS GLUCOWATCH AUTOMATIC GLUCOSE BIOGRAPHER | Animas Corp. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.