Nova
Nova 16 Glucose Membrane KIT: Refrigerate
Who Else Makes It
Concentrated in Guangdong (3), Zhejiang (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Flextronics Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Yasee Biomedical Inc | Qingdao | Shandong | Contract manufacturer | 5 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
| Shenzhen Yuwen E-Commerce Co., Ltd. | Shenzhen | Guangdong | Repacker / relabeller | 19 |
| Tianjin Empecs Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 8 |
Record
| Listed by | Nova Biomedical Corporation, United States |
|---|---|
| FDA product code | CGA |
| Device type | Glucose Oxidase, Glucose |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1345 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K963005 |
| Record published | 2016-09-16 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Handling environment temperature 15 to 30 °C; Storage environment temperature 15 to 30 °C |
| Packaging | Carton of 2 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 16 | In distribution | ||
| 14 | In distribution | ||
| 16 | 3 | In distribution | |
| 1 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| i-STAT | Abbott Point OF Care Inc. | 48 |
| YSI Incorporated | YSI Incorporated | 34 |
| Auvon | Shenzhen Yuwen E-Commerce Co., Ltd. | 28 |
| Stat Profile | Nova Biomedical Corporation | 17 |
| Fora | Fora Care Inc. | 13 |
| TRUEtrack | Trividia Health, Inc. | 12 |
| JAS Diagnostics | Drew Scientific, Ltd. | 11 |
| StatStrip | Nova Biomedical Corporation | 9 |
| Gluc-PAP | Randox Laboratories Limited | 8 |
| Nova Primary | Nova Biomedical Corporation | 8 |
| Synermed® | Infrared Laboratory Systems LLC | 7 |
| Prodigy No Coding Blood Glucose Test Strips | Prodigy Diabetes Care, LLC | 7 |
Showing 12 of 215. All products under Glucose Oxidase, Glucose
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K203549 | 2022-10-18 |
| K200349 | 2020-03-13 |
| K180340 | 2018-09-26 |
| K070960 | 2007-07-11 |
| K063821 | 2007-01-24 |
| K060345 | 2006-04-28 |
| K924743 | 1992-11-06 |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2013-10-10 | Class II | Component design/selection | Revised Battery Instructions for Removal and Expiration Date due to battery swelling and cell leakage | est. 200,000 | 2014-03-24 |
| 2013-02-25 | Class II | Process design | Glucose test strips reports no result message when tested | 7433 cases | 2014-09-26 |
| 2013-02-25 | Class II | Process design | Glucose test strips reports no result message when tested | 2200 cases | 2014-09-26 |
| 2010-02-12 | Not classified | Nonconforming Material/Component | Glucose strips report low glucose results | 392 Cases (1800 strips each) | 2011-07-22 |
| 2008-02-21 | Not classified | Component design/selection | Lithium batteries may fail if the glucose or creatinine meters have been dropped. | 4432 batteries | 2008-10-28 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P990026 | 2002-02-04 | CYGNUS GLUCOWATCH AUTOMATIC GLUCOSE BIOGRAPHER | Animas Corp. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.