On Call Express Mobile Blood Glucose Monitoring System
Blood Glucose Meter, vial of 10 strips, 2mL bottle of Control 1, lancing device, 10 lancets (30G)
Who Else Makes It
Concentrated in Guangdong (3), Zhejiang (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Flextronics Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Yasee Biomedical Inc | Qingdao | Shandong | Contract manufacturer | 5 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
| Shenzhen Yuwen E-Commerce Co., Ltd. | Shenzhen | Guangdong | Repacker / relabeller | 19 |
| Tianjin Empecs Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 8 |
Record
| Listed by | Acon Laboratories, Inc., United States |
|---|---|
| FDA product code | CGA |
| Device type | Glucose Oxidase, Glucose |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1345 |
| Establishment | Contract manufacturer, Specification developer, Manufacturer |
| 510(k) | K180196 |
| Record published | 2019-06-14 |
| Record revised | 2025-06-20 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Over the counter | Yes |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date, serial number |
| Storage | Storage environment temperature 41 to 86 °F; Special storage condition: Store in a cool, dry place at 10-90% Relative Humidity. Keep out of direct sunlight. |
| Packaging | Case of 4, carton of 6 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| G115-10S | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| i-STAT | Abbott Point OF Care Inc. | 48 |
| YSI Incorporated | YSI Incorporated | 34 |
| Auvon | Shenzhen Yuwen E-Commerce Co., Ltd. | 28 |
| Stat Profile | Nova Biomedical Corporation | 17 |
| Fora | Fora Care Inc. | 13 |
| TRUEtrack | Trividia Health, Inc. | 12 |
| JAS Diagnostics | Drew Scientific, Ltd. | 11 |
| StatStrip | Nova Biomedical Corporation | 9 |
| Gluc-PAP | Randox Laboratories Limited | 8 |
| Nova Primary | Nova Biomedical Corporation | 8 |
| Synermed® | Infrared Laboratory Systems LLC | 7 |
| Prodigy No Coding Blood Glucose Test Strips | Prodigy Diabetes Care, LLC | 7 |
Showing 12 of 215. All products under Glucose Oxidase, Glucose
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K122110 | 2012-11-21 |
| K111371 | 2011-10-06 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P990026 | 2002-02-04 | CYGNUS GLUCOWATCH AUTOMATIC GLUCOSE BIOGRAPHER | Animas Corp. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.