Vitros

VITROS XT Chemistry Products GLU-Ca Slides

Registry build 21.09.26
8manufacturers in China registered for this device type
2catalogue numbers in this listing
2510(k) clearances naming this product code
6recalls on this code

Who Else Makes It

Concentrated in Guangdong (3), Zhejiang (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code CGA
Manufacturer City Province Registered as Device types
Acon Biotech (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 29
Dongguan BAO Kang Dian ZI KE JI Limited Dongguan Guangdong Contract manufacturer 24
Flextronics Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 5
Yasee Biomedical Inc Qingdao Shandong Contract manufacturer 5
Jiangsu NEW Pentastar Medical Products Co., Ltd. Changzhou Jiangsu Exporter 146
Vivachek Biotech (Hangzhou) Co., Ltd. Hangzhou, Zhuji Zhejiang Contract manufacturer 21
Shenzhen Yuwen E-Commerce Co., Ltd. Shenzhen Guangdong Repacker / relabeller 19
Tianjin Empecs Medical Device Co., Ltd. Tianjin Tianjin Contract manufacturer 8

Record

Regulatory record for Vitros
Listed by Ortho-Clinical Diagnostics, Inc., United States
FDA product code CGA
Device type Glucose Oxidase, Glucose
Device class Class 2
Regulation 21 CFR 862.1345
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2019-11-13
Record revised 2023-06-21 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Special storage condition: Store at or below -18; Storage environment temperature -18 to -18 °C
Packaging Case of 30

Catalogue Numbers

Catalogue numbers for Vitros
Catalogue number Size Status
6844295 In distribution
1707801 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
i-STAT Abbott Point OF Care Inc. 48
YSI Incorporated YSI Incorporated 34
Auvon Shenzhen Yuwen E-Commerce Co., Ltd. 28
Stat Profile Nova Biomedical Corporation 17
Fora Fora Care Inc. 13
TRUEtrack Trividia Health, Inc. 12
JAS Diagnostics Drew Scientific, Ltd. 11
StatStrip Nova Biomedical Corporation 9
Gluc-PAP Randox Laboratories Limited 8
Nova Primary Nova Biomedical Corporation 8
Synermed® Infrared Laboratory Systems LLC 7
Prodigy No Coding Blood Glucose Test Strips Prodigy Diabetes Care, LLC 7

Showing 12 of 215. All products under Glucose Oxidase, Glucose

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K190520 2019-04-03
K163433 2017-09-18

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Vitros
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Ortho-Clinical Diagnostics, Inc. UDI-DI 2019-06-17 Class II Process control Potentially Biased Results using VITROS Chemistry Products GLU Slides 1099 (5 pack x 60)=329700 slides 2020-11-09

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-08-11 Class II Under Investigation by firm Ortho Clinical Diagnostics confirmed that N-Acetylcysteine (NAC), a drug used for acetaminophen overdose, mucolytic therapy and is used as nutritional supplement, can interfere with VITROS GLU, LAC, TRIG, and URIC Slides assays. Ortho also US: 192,459 sales units; Foreign: 231,710 sales units 2018-06-11
2013-06-12 Class II Equipment maintenance Ortho Clinical Diagnostics is recalling Slide Dispense cartridges used with some VITROS Chemistry Product Slides due to slide dispense issues. 349,072 units (142,455 units domestically & 205,617 units in 2017-04-11
2006-09-27 Not classified Other Positively biased results when using the VITROS Chemistry Products GLU DT Slides GEN 56. 93,252 boxes (25 slides per box) in total 2012-08-03
2003-07-28 Not classified Other Results of glucose measurements on sodium fluoride/potassium oxalate specimens can be negatively biased when using Vitros GLU and GLU DT slides stored in the refrigerator. 210,050 boxes 2003-11-24
2003-07-28 Not classified Other Results of glucose measurements on sodium fluoride/potassium oxalate specimens can be negatively biased when using Vitros GLU and GLU DT slides stored in the refrigerator. GLU slides are processed by high volume chemistry systems typically 487,912 boxes 2003-11-24

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P990026 2002-02-04 CYGNUS GLUCOWATCH AUTOMATIC GLUCOSE BIOGRAPHER Animas Corp.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.