Vitros
VITROS XT Chemistry Products GLU-Ca Slides
Who Else Makes It
Concentrated in Guangdong (3), Zhejiang (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Flextronics Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Yasee Biomedical Inc | Qingdao | Shandong | Contract manufacturer | 5 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
| Shenzhen Yuwen E-Commerce Co., Ltd. | Shenzhen | Guangdong | Repacker / relabeller | 19 |
| Tianjin Empecs Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 8 |
Record
| Listed by | Ortho-Clinical Diagnostics, Inc., United States |
|---|---|
| FDA product code | CGA |
| Device type | Glucose Oxidase, Glucose |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1345 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2019-11-13 |
| Record revised | 2023-06-21 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Store at or below -18; Storage environment temperature -18 to -18 °C |
| Packaging | Case of 30 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 6844295 | In distribution | |
| 1707801 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| i-STAT | Abbott Point OF Care Inc. | 48 |
| YSI Incorporated | YSI Incorporated | 34 |
| Auvon | Shenzhen Yuwen E-Commerce Co., Ltd. | 28 |
| Stat Profile | Nova Biomedical Corporation | 17 |
| Fora | Fora Care Inc. | 13 |
| TRUEtrack | Trividia Health, Inc. | 12 |
| JAS Diagnostics | Drew Scientific, Ltd. | 11 |
| StatStrip | Nova Biomedical Corporation | 9 |
| Gluc-PAP | Randox Laboratories Limited | 8 |
| Nova Primary | Nova Biomedical Corporation | 8 |
| Synermed® | Infrared Laboratory Systems LLC | 7 |
| Prodigy No Coding Blood Glucose Test Strips | Prodigy Diabetes Care, LLC | 7 |
Showing 12 of 215. All products under Glucose Oxidase, Glucose
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K190520 | 2019-04-03 |
| K163433 | 2017-09-18 |
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Ortho-Clinical Diagnostics, Inc. | UDI-DI | 2019-06-17 | Class II | Process control | Potentially Biased Results using VITROS Chemistry Products GLU Slides | 1099 (5 pack x 60)=329700 slides | 2020-11-09 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2016-08-11 | Class II | Under Investigation by firm | Ortho Clinical Diagnostics confirmed that N-Acetylcysteine (NAC), a drug used for acetaminophen overdose, mucolytic therapy and is used as nutritional supplement, can interfere with VITROS GLU, LAC, TRIG, and URIC Slides assays. Ortho also | US: 192,459 sales units; Foreign: 231,710 sales units | 2018-06-11 |
| 2013-06-12 | Class II | Equipment maintenance | Ortho Clinical Diagnostics is recalling Slide Dispense cartridges used with some VITROS Chemistry Product Slides due to slide dispense issues. | 349,072 units (142,455 units domestically & 205,617 units in | 2017-04-11 |
| 2006-09-27 | Not classified | Other | Positively biased results when using the VITROS Chemistry Products GLU DT Slides GEN 56. | 93,252 boxes (25 slides per box) in total | 2012-08-03 |
| 2003-07-28 | Not classified | Other | Results of glucose measurements on sodium fluoride/potassium oxalate specimens can be negatively biased when using Vitros GLU and GLU DT slides stored in the refrigerator. | 210,050 boxes | 2003-11-24 |
| 2003-07-28 | Not classified | Other | Results of glucose measurements on sodium fluoride/potassium oxalate specimens can be negatively biased when using Vitros GLU and GLU DT slides stored in the refrigerator. GLU slides are processed by high volume chemistry systems typically | 487,912 boxes | 2003-11-24 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P990026 | 2002-02-04 | CYGNUS GLUCOWATCH AUTOMATIC GLUCOSE BIOGRAPHER | Animas Corp. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.