Dimension Vista® Flex® Reagent Cartridge Lipl

Liquid Lipase Flex® reagent cartridge, 480 tests

Registry build 21.09.26
2manufacturers in China registered for this device type
1catalogue number
6recalls on this code

Who Else Makes It

Concentrated in Jilin (1), Shandong (1).

Chinese manufacturers registered for FDA product code CHI
Manufacturer City Province Registered as Device types
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70

Record

Regulatory record for Dimension Vista® Flex® reagent cartridge Lipl
Listed by Siemens Healthcare Diagnostics Inc, United States
FDA product code CHI
Device type Lipase-Esterase, Enzymatic, Photometric, Lipase
Device class Class 1
Regulation 21 CFR 862.1465
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2020-09-24
Record revised 2024-06-19 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries lot or batch number, expiry date
Storage Storage environment temperature 2 to 8 °C
Distribution end date 2024-06-09

Catalogue Numbers

Catalogue numbers for Dimension Vista® Flex® reagent cartridge Lipl
Catalogue number Size Per pack Status
10461745 4 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Biobase Biobase Biodustry(Shandong)Co., Ltd. 7
Lipase (LPS) Randox Laboratories Limited 4
Carolina Liquid Chemistries Corp.® Lipase Reagent KIT ST621 Carolina Liquid Chemistries 4
Lipase colorimetric assay Roche Diagnostics Gmbh 3
Architect Abbott Ireland 2
Vitros Ortho-Clinical Diagnostics, Inc. 2
Pointe Scientific, Inc. Lipase-Color Horiba Instruments Incorporated 2
Alinity Abbott Ireland 2
Architect Abbott Laboratories 1
MedTest Dx, Inc. Lipase (Colorimetric) Medtest DX 1
Lipase NG OC Reagent Kit Sentinel CH. SPA 1
Lipase colorimetric Roche Diagnostics Gmbh 1

Showing 12 of 28. All products under Lipase-Esterase, Enzymatic, Photometric, Lipase

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-12-20 Class II Under Investigation by firm Firm has received customer complaints regarding failed calibrations and increased imprecision of quality control and patient samples when using this product. 3224 2020-12-21
2018-09-07 Class II Under Investigation by firm There is lot to lot variability for QC and patient results when using the identified reagent cartridge lots. 18396 2020-11-16
2018-09-07 Class II Under Investigation by firm There is lot to lot variability for QC and patient results when using the identified reagent cartridge lots. 3956 2020-11-16
2017-12-14 Class II Under Investigation by firm Calibration failure – confirmed a positive bias with LIPL lot FB8109 when compared to other Dimension LIPL lots. Lot FB8109 is not meeting Siemens internal specifications for lot-to-lot limits. 2020-12-03
2015-03-23 Class II Device Design Siemens internal investigation confirmed that current contamination avoidance settings do not prevent carryover resulting in falsely elevated ADVIA Chemistry Lipase outlier results when running with Triglycerides, Triglycerides_2, Triglycer 7814 2015-12-18
2010-03-10 Not classified Other Open Well instability: After calibration, QC shifts high (out of range) after the Flex Well is hydrated. Shifts of up to 20% have been observed in both QC and patient samplesas soon as two hours post hydration. 21171 2011-08-04

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.