BG Cartridge

BG Cartridge, 25 count

Registry build 21.09.26
1manufacturer
2catalogue numbers in this listing
3recalls on this code

Who Else Makes It

Registered in Guangdong.

Chinese manufacturers registered for FDA product code CHL
Manufacturer City Province Registered as Device types
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56

Record

Regulatory record for BG Cartridge
Listed by LifeHealth, LLC
FDA product code CHL
Device type Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph
Device class Class 2
Regulation 21 CFR 862.1120
Record published 2016-09-24
Record revised 2018-03-29 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Label carries lot or batch number, expiry date
Storage Storage environment temperature 15 to 30 °C

Catalogue Numbers

Catalogue numbers for BG Cartridge
Catalogue number Size Per pack Status
049110 25 In distribution
049110 10 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Stat Profile Nova Biomedical Corporation 80
ABL80 SC80 Radiometer Medical APS 66
ABL77 Sci Radiometer Medical APS 14
Electrode for ABL analyzers Radiometer Medical APS 7
Calibration Solution Radiometer Medical APS 7
i-STAT Abbott Point OF Care Inc. 6
ABL90 Sensor Cassette pack Radiometer Medical APS 6
GEM Premier 7000 with iQM3 PAK (BG/ISE/GL/COOX/Tbili 450 Tests) Instrumentation Laboratory SPA 5
Nova Nova Biomedical Corporation 4
GEM Premier 7000 with iQM3 PAK (BG/ISE/COOX/Tbili 150 Tests) Instrumentation Laboratory SPA 4
Calibration Gas 2 Radiometer Medical APS 3
Ready Sensor™ Lactate Biosensor Siemens Healthcare Diagnostics Inc 3

Showing 12 of 235. All products under Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-09-16 Class II Nonconforming Material/Component May report values outside the published performance specifications for pH. After a certain point in shelf life, the pH sensor may give results that are falsely elevated. The discrepancy is greater as shelf life progresses and can be seen o 1735 boxes of 25. (43375 Cartridges) 2016-03-21
2015-09-16 Class II Nonconforming Material/Component May report values outside the published performance specifications for pH. After a certain point in shelf life, the pH sensor may give results that are falsely elevated. The discrepancy is greater as shelf life progresses and can be seen o 4659 boxes of 25. (116475 cartridges) 2016-03-21
2015-04-29 Class II Nonconforming Material/Component The barometric pressure measurement output of this particular IRMA TRUPoint SN 443914 device will drift over time. 7 2015-10-20

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.