NA Electrode, ISE Module
Clinical Chemistry Test Systems / Sodium test system. A sodium test system is a device intended to measure sodium in serum, plasma, and urine. Measurements obtained by this device are used…
Clinical Chemistry Test Systems / Sodium test system. A sodium test system is a device intended to measure sodium in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of aldosteronism (excessive secretion of the hormone aldosterone), diabetes insipidus (chronic excretion of large amounts of dilute urine, accompanied by extreme thirst), adrenal hypertension, Addison’s disease (caused by destruction of the adrenal glands), dehydration, inappropriate antidiuretic hormone secretion, or other diseases involving electrolyte imbalance.
Who Else Makes It
All of them in Guangdong.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
Record
| Listed by | Diatron Medicinai Instrumentumok Laboratoriumi Diagnosztikai Fejleszto-Gyarto Zartkoruen Mukodo Reszvenytarsasag |
|---|---|
| FDA product code | JGS |
| Device type | Electrode, Ion Specific, Sodium |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1665 |
| 510(k) | K101741 |
| Record published | 2016-10-06 |
| Record revised | 2025-11-20 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 4 to 25 °C |
| Packaging | Box |
| Sizes | Height 60 mm; depth 40 mm; width 90 mm |
| Distribution end date | 2025-11-19 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| NA+ Electrode | Height 60 mm | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Stat Profile | Nova Biomedical Corporation | 13 |
| i-STAT | Abbott Point OF Care Inc. | 9 |
| AU | Beckman Coulter, Inc. | 8 |
| GEM Premier ChemSTAT PAK Na+,K+,Ca++,Cl-, Glu, Crea, BUN, tCO2, Hct, Lac,pH,pCO2 | Instrumentation Laboratory SPA | 8 |
| Nova | Nova Biomedical Corporation | 6 |
| Phoenix Diagnostics, Inc. | Phoenix Diagnostics, Inc. | 5 |
| Sodium Electrode | Roche Diagnostics Gmbh | 4 |
| Pointe Scientific, Inc. | Horiba Instruments Incorporated | 3 |
| Architect | Abbott Laboratories | 3 |
| Synermed® | Infrared Laboratory Systems LLC | 3 |
| Sodium Electrode | Diamond Diagnostics Inc. | 3 |
| Phoenix Diagnostics | Phoenix Diagnostics, Inc. | 2 |
Showing 12 of 88. All products under Electrode, Ion Specific, Sodium
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.