safePICO
1-Adhesive Bandage, 1-Alcohol Prep Pad, 1-Sterile Gauze Pad, 1-Bio Bag with gusset bottom, 1 safePICO 25Gx16mm (nsd) Arterial blood sampler with 23Gx16mm needle, with needle shield device…
1-Adhesive Bandage, 1-Alcohol Prep Pad, 1-Sterile Gauze Pad, 1-Bio Bag with gusset bottom, 1 safePICO 25Gx16mm (nsd) Arterial blood sampler with 23Gx16mm needle, with needle shield device (nsd) and vented TIPCAP, 1.5 mL, box of 100 pcs.
Who Else Makes It
Concentrated in Jiangsu (7), Zhejiang (6), Shanghai (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Promisemed Hangzhou Meditech Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 21 |
| Beilun Plastech Inc | Ningbo | Zhejiang | Contract manufacturer | 13 |
| Weihai Jierui Medical Products Co., Ltd. | Weihai | Shandong | Contract manufacturer | 3 |
| Tianjin Hanaco Medical Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 3 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Zhejiang Medicines & Health Products I/ E Co., Ltd. | Hangzhou | Zhejiang | Exporter | 41 |
| Jiangsu Caina Medical Co., Ltd. | Jiangyin | Jiangsu | Contract manufacturer | 20 |
| Hangzhou Best Valley Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Exporter | 20 |
| Zhejiang Kindly Medical Devices Co., Ltd. | Wenzhou | Zhejiang | Contract manufacturer | 16 |
| Jiangsu Rongye Technology Co., Ltd. | Yangzhou | Jiangsu | Manufacturer | 16 |
| Yangzhou Medline Industry Co., Ltd. | Yangzhou | Jiangsu | Contract manufacturer | 11 |
| Shanghai Mekon Medical Devices Co., Ltd. | Shanghai | Shanghai | Exporter | 11 |
Showing 12 of 23. All 23 manufacturers in China registered for Tubes, Vials, Systems, Serum Separators, Blood Collection
Record
| Listed by | Radiometer America, Inc., United States |
|---|---|
| FDA product code | JKA |
| Device type | Tubes, Vials, Systems, Serum Separators, Blood Collection |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1675 |
| Establishment | Repacker / relabeller, Complaint-file establishment |
| Record published | 2020-09-25 |
| Record revised | 2021-03-26 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Storage | Storage environment temperature 2 to 32 °C |
| Distribution end date | 2021-03-25 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 623-KIT | In distribution | |
| 616-KIT Box of 100 | Withdrawn | |
| 623-KIT Box of 100 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Portex | ICU Medical, Inc | 182 |
| S-Monovette® | Sarstedt Aktiengesellschaft & Co.KG | 108 |
| Vacuette | Greiner BIO-ONE Gmbh | 106 |
| Jelco | ICU Medical, Inc | 35 |
| Kbmed | KB Medical (Group) Inc. | 33 |
| Marketlab Inc | Marketlab Incorporated | 30 |
| Maveric Medical | Maveric Medical LLC | 27 |
| Safe-T-Fill® | Ram Scientific | 23 |
| Improvacuter® Gel & Clot Activator Tube | Guangzhou Improve Medical Instruments Co., Ltd. | 21 |
| Medline | Medline Industries, Inc. | 20 |
| Kurin Blood Culture Collection Set | Kurin, Inc. | 20 |
| Reli | Myco Medical Supplies, Inc. | 18 |
Showing 12 of 303. All products under Tubes, Vials, Systems, Serum Separators, Blood Collection
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K962158 | 1996-10-29 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2006-07-18 | Not classified | Other | Leaking Tip Caps-Tip caps may leak; after air has been expelled from the syringe through the vented safe tip caps. | 448 boxes x 100 per box [44,800 pouches] | 2011-09-14 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.