FreeStyle Freedom Lite
FreeStyle Freedom Lite Blood Glucose and Monitoring System
Who Else Makes It
Concentrated in Tianjin (2), Guangdong (2), Jiangsu (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Andon Health Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 22 |
| Flextronics Medical Device Manufacturing (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 6 |
| Flextronics Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Tianjin Empecs Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 8 |
Record
| Listed by | Abbott Diabetes Care Limited, United Kingdom |
|---|---|
| FDA product code | LFR |
| Device type | Glucose Dehydrogenase, Glucose |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1345 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| Record published | 2016-09-02 |
| Record revised | 2024-05-16 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Over the counter | Yes |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date, serial number |
| Storage | Storage environment temperature 40 to 86 °F |
| Packaging | Case of 4 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 70920 | In distribution | |
| 70914 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| True Metrix | Trividia Health, Inc. | 15 |
| Contour® | Ascensia Diabetes Care US Inc. | 10 |
| Fora | Fora Care Inc. | 9 |
| Contour® Next ONE | Ascensia Diabetes Care US Inc. | 9 |
| True Metrix GO | Trividia Health, Inc. | 8 |
| OneTouch Verio | Lifescan Europe Gmbh | 8 |
| Accu-Chek Aviva Plus | Roche Diagnostics Operations | 7 |
| McKesson | Mckesson Medical-Surgical Inc. | 7 |
| Accu-Chek Guide | Roche Diagnostics Operations | 7 |
| Contour® Next | Ascensia Diabetes Care US Inc. | 6 |
| Accu-Chek Smart View | Roche Diagnostics Operations | 6 |
| FreeStyle Lite | Abbott Diabetes Care Limited | 5 |
Showing 12 of 124. All products under Glucose Dehydrogenase, Glucose
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K083223 | 2009-04-16 |
| K070984 | 2007-11-01 |
| K000582 | 2000-12-05 |
| K994433 | 2000-05-05 |
| K992684 | 2000-01-14 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2008-04-24 | Not classified | Process control | Flaws in strip voltage continuity may result in frequency of an Error 3 (“Er3”) message display and unreadable strips. This issue has the potential for creating a delay in generating blood glucose results and to delay diabetes management, | 2954900 strips | 2011-03-29 |
| 2005-08-30 | Not classified | Other | Downloadable software obtained from the firm’s website displays user data (including but not limited to insulin levels and pump statistics data) in a matter that may be misinterpreted and result in mistreatment of therapy. | Product is downloadable software | 2006-05-16 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.