Accu-Chek Aviva Plus
Accu-Chek Aviva Plus Sample KIT 16/CASE
Who Else Makes It
Concentrated in Guangdong (8), Jiangsu (4), Zhejiang (4). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Dongguan Honfield Precision Parts Co., Ltd. | Zhangmutou, Dongguan | Guangdong | Contract manufacturer | 8 |
| Flextronics Medical Device Manufacturing (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 6 |
| Flextronics Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Yasee Biomedical Inc | Qingdao | Shandong | Contract manufacturer | 5 |
| Altek Medical (kunshan) limited | Kunshan Free Trade Zone | Jiangsu | Contract manufacturer | 2 |
| Dongguan Kaifa Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 2 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Andon Health Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 22 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
Showing 12 of 20. All 20 manufacturers in China registered for System, Test, Blood Glucose, Over The Counter
Record
| Listed by | Roche Diagnostics Operations, United States |
|---|---|
| FDA product code | NBW |
| Device type | System, Test, Blood Glucose, Over The Counter |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1345 |
| Record published | 2016-08-26 |
| Record revised | 2023-07-06 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date, serial number |
| Packaging | Pack of 8, pack of 16, pack of 12 |
| Distribution end date | 2022-10-04 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 06988563001 | Withdrawn | |
| 07021941001 | Withdrawn | |
| 06988601001 | Withdrawn | |
| 06988580001 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| True Metrix | Trividia Health, Inc. | 40 |
| Fora | Fora Care Inc. | 31 |
| True Metrix AIR | Trividia Health, Inc. | 21 |
| GE | Bionime Corporation | 21 |
| TRUEtrack | Trividia Health, Inc. | 17 |
| Medline | Medline Industries, Inc. | 15 |
| AgaMatrix | Agamatrix | 15 |
| Tenovi | Tenovi Co | 13 |
| Auvon | Shenzhen Yuwen E-Commerce Co., Ltd. | 11 |
| Accu-Chek Guide | Roche Diagnostics Operations | 10 |
| Curaplex | Bound Tree Medical, LLC | 10 |
| OneTouch Verio | Lifescan Europe Gmbh | 10 |
Showing 12 of 476. All products under System, Test, Blood Glucose, Over The Counter
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K131029 | 2013-08-09 |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2014-04-14 | Class II | Device Design | Roche Diabetes Care has become aware the ACCU-CHEK Compact Plus test strips may produce erroneously low blood glucose readings in patients undergoing Ceftriaxone therapy. The interference is not described in the product labeling. | 590,136 boxes | 2014-09-18 |
| 2013-10-25 | Class II | Software design | There is a software synchronization issue with the ACCU-CHEK Combo system. In rare cases, when the Manual Pump option is chosen on the ACCU-CHEK Aviva Combo meter, there is a possibility of receiving an incorrect bolus advice recommendation | 6,595 units | 2015-01-14 |
| 2013-03-06 | Class II | Device Design | Roche investigation into complaints found Accu-Chek Inform II and CoaguChek XS Pro System barcode reading meters had the potential of intermittent erroneous decoding of patient identification if barcodes being read fail to meet size and/or | Both devices 4467 | 2018-01-10 |
| 2012-03-12 | Not classified | Employee error | Accu-Chek Aviva Nano Blood Glucose meters that were manufactured for the purpose of validating a manufacturing process for product to be distributed outside the US were distributed in the US through eBay by an unauthorized third party. The | 82 meter distributed on Ebay | 2012-11-06 |
| 2011-05-18 | Not classified | Component design/selection | Erroneous results: Internal investigations revealed that the test strips exhibited a performance issue that can cause test strip errors or a bias in test result that exceed the tolerance range according to EN ISO 15197. | 27,019 units | 2011-10-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.