TRUEread
TRUEread 50 Blood Glucose Test Strips
Who Else Makes It
Concentrated in Guangdong (8), Jiangsu (4), Zhejiang (4). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Dongguan Honfield Precision Parts Co., Ltd. | Zhangmutou, Dongguan | Guangdong | Contract manufacturer | 8 |
| Flextronics Medical Device Manufacturing (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 6 |
| Flextronics Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Yasee Biomedical Inc | Qingdao | Shandong | Contract manufacturer | 5 |
| Altek Medical (kunshan) limited | Kunshan Free Trade Zone | Jiangsu | Contract manufacturer | 2 |
| Dongguan Kaifa Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 2 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Andon Health Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 22 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
Showing 12 of 20. All 20 manufacturers in China registered for System, Test, Blood Glucose, Over The Counter
Record
| Listed by | Trividia Health, Inc., United States |
|---|---|
| FDA product code | NBW |
| Device type | System, Test, Blood Glucose, Over The Counter |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1345 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K042080 |
| Record published | 2016-09-20 |
| Record revised | 2021-11-01 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Over the counter | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 40 to 86 °F |
| Packaging | Case of 24, box, case of 360 |
| Distribution end date | 2017-10-12 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| TRUEread 50 Blood Glucose Test Strips | 50 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| True Metrix | Trividia Health, Inc. | 40 |
| Fora | Fora Care Inc. | 31 |
| True Metrix AIR | Trividia Health, Inc. | 21 |
| GE | Bionime Corporation | 21 |
| TRUEtrack | Trividia Health, Inc. | 17 |
| Medline | Medline Industries, Inc. | 15 |
| AgaMatrix | Agamatrix | 15 |
| Tenovi | Tenovi Co | 13 |
| Auvon | Shenzhen Yuwen E-Commerce Co., Ltd. | 11 |
| Accu-Chek Guide | Roche Diagnostics Operations | 10 |
| Curaplex | Bound Tree Medical, LLC | 10 |
| OneTouch Verio | Lifescan Europe Gmbh | 10 |
Showing 12 of 476. All products under System, Test, Blood Glucose, Over The Counter
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K262116 | 2026-07-23 |
| K143548 | 2016-04-01 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Trividia Health, Inc. | 510(k) number | 2016-06-28 | Class II | Nonconforming Material/Component | Product gives incorrect low blood glucose levels. | 5,527,921 In total =4,621,639 strips & 393,808 kits domestic |
Recalls
4 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2026-02-06 | Class I | Software design | The system labeling (user manual and online labeling) did not provide adequate directions for lay users to act on the E-5 error code. The error code description and recommended actions for the E-5 error code in the labeling do not: (a) clea | 3,678,026 | |
| 2026-02-06 | Class I | Software design | The system labeling (user manual and online labeling) did not provide adequate directions for lay users to act on the E-5 error code. The error code description and recommended actions for the E-5 error code in the labeling do not: (a) clea | 12,067,458 | |
| 2026-02-06 | Class I | Software design | The system labeling (user manual and online labeling) did not provide adequate directions for lay users to act on the E-5 error code. The error code description and recommended actions for the E-5 error code in the labeling do not: (a) clea | 1,001,534 | |
| 2026-02-06 | Class I | Software design | The system labeling (user manual and online labeling) did not provide adequate directions for lay users to act on the E-5 error code. The error code description and recommended actions for the E-5 error code in the labeling do not: (a) clea | 1,407,465 | |
| 2025-10-07 | Class II | Device Design | Manufacturing defect causing LCD display issues with missing or partial segments (ghosting) that can result in misreading glucose values, potentially leading to inappropriate treatment decisions for diabetes management. | 601 units | |
| 2020-04-20 | Class II | Process control | One (1) TRUE METRIX AIR blood glucose meter distributed in the United States was packaged into a TRUE METRIX blood glucose meter kit and has an incorrect factory-set unit of measure; the meter displays glucose results in mmol/L rather than | 1 unit | 2021-06-01 |
| 2016-06-28 | Class II | Nonconforming Material/Component | Product gives incorrect low blood glucose levels. | 5,527,921 In total =4,621,639 strips & 393,808 kits domestic | |
| 2016-06-28 | Class II | Nonconforming Material/Component | Product gives incorrect low blood glucose levels. | 5,527,921 In total =4,621,639 strips & 393,808 kits domestic | |
| 2016-06-28 | Class II | Nonconforming Material/Component | Product gives incorrect low blood glucose levels. | 5,527,921 In total =4,621,639 strips & 393,808 kits domestic | |
| 2013-10-02 | Class II | Software design (manufacturing process) | Manufactured with an incorrect factory set unit of measure. | 501 | 2016-01-28 |
| 2013-10-02 | Class II | Software design (manufacturing process) | Manufactured with an incorrect factory set unit of measure. | 105 | 2016-01-28 |
| 2013-02-25 | Class II | Environmental control | Meter kit outer boxes containing 10 ct. test strips state incorrect storage temperature range. | 1,627 Kits | 2013-07-08 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.