QC Sets and Panels: Helix Elite™
QC Sets and Panels: Helix Elite™ Rifampicin-Resistant Mycobacterium tuberculosis Positive Control Panel (Inactivated Pellet)
Who Else Makes It
Concentrated in Jilin (1), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Phase Scientific (Shenzhen) Company Limited | Shenzhen | Guangdong | Repacker / relabeller | 8 |
Record
| Listed by | Microbiologics, Inc., United States |
|---|---|
| FDA product code | OHQ |
| Device type | Multi-Analyte Controls Unassayed |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1660 |
| Establishment | Contract manufacturer, Repacker / relabeller, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2025-09-08 |
| Record revised | 2022-10-03 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 25 °C |
| Distribution end date | 2026-05-20 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 8248 | In distribution | |
| 8249 | In distribution | |
| 8189 | In distribution | |
| 8187 | In distribution | |
| 8247 | In distribution | |
| 8238 | In distribution | |
| 8246 | In distribution | |
| 8205 | In distribution | |
| 8208 | In distribution | |
| 8206 | In distribution | |
| 8258 | In distribution | |
| 8269 | In distribution | |
| 8236 | In distribution | |
| 8210 | In distribution | |
| ABT-001 | In distribution | |
| 8231 | In distribution | |
| 8209 | In distribution | |
| 8268 | In distribution | |
| 8191 | In distribution | |
| 8232 | In distribution | |
| 8245 | In distribution | |
| 8234 | In distribution | |
| 8227 | In distribution | |
| 8246-SPL | In distribution | |
| 8230 | In distribution | |
| 8184 | In distribution | |
| 8219 | In distribution | |
| 8228 | In distribution | |
| 8235 | In distribution | |
| 8255 | In distribution | |
| 8211 | In distribution | |
| 8181 | In distribution | |
| 8250 | In distribution | |
| 8267 | In distribution | |
| 8180 | In distribution | |
| 8203 | In distribution | |
| 8229 | In distribution | |
| 8254 | In distribution | |
| 8242 | In distribution | |
| 8198 | Withdrawn | |
| 8190 | Withdrawn | |
| 8240 | Withdrawn | |
| 8214 | Withdrawn | |
| 8217 | Withdrawn | |
| 8215 | Withdrawn | |
| 8233 | Withdrawn | |
| 8182 | Withdrawn | |
| CL00016 | Withdrawn | |
| 8216 | Withdrawn | |
| 8201 | Withdrawn | |
| 8244 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Exact Diagnostics | Exact Diagnostics | 64 |
| NATtrol™ | Zeptometrix LLC. | 54 |
| Helix Elite™ Molecular Standards: Inactivated Standard | Microbiologics, Inc. | 41 |
| Multichem S Plus | Techno-Path Manufacturing Ltd. | 35 |
| Virotrol | Bio-Rad Laboratories Inc. | 27 |
| Helix Elite™ Molecular Standards: Synthetic Standard | Microbiologics, Inc. | 25 |
| Multichem IA Plus | Techno-Path Manufacturing Ltd. | 17 |
| D3 | Diagnostic Hybrids, Inc. | 14 |
| Liquichek | Bio-Rad Laboratories Inc. | 10 |
| Multichem IA | Techno-Path Manufacturing Ltd. | 8 |
| QC Sets and Panels: Kwik-Stik™ 2 Pack | Microbiologics, Inc. | 8 |
| QC Sets and Panels: Kwik-Stik™ | Microbiologics, Inc. | 7 |
Showing 12 of 107. All products under Multi-Analyte Controls Unassayed
Recalls Naming This Product
5 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Microbiologics, Inc. | UDI-DI | 2025-01-20 | Class II | Under Investigation by firm | Internal quality control procedures were not followed correctly for the testing/release of three lots of 8234/8235. This resulted in the release of products that should have failed and been discarded. The concentration of one target (HPV 16 | 16 units | |
| Microbiologics, Inc. | UDI-DI | 2025-01-20 | Class II | Under Investigation by firm | Internal quality control procedures were not followed correctly for the testing/release of three lots of 8234/8235. This resulted in the release of products that should have failed and been discarded. The concentration of one target (HPV 16 | 27 units | |
| Microbiologics, Inc. | UDI-DI | 2024-01-08 | Class II | Process control | The negative control was contaminated with one of the positive control pathogens (Norovirus). This would result in users getting a positive call for Norovirus when running the negative control. | 580 packages | |
| Microbiologics, Inc. | UDI-DI | 2022-03-03 | Class II | Incorrect or no expiration date | Shelf-life for the 8244 Pneumonia (33 Targets) Control Panel determined to be 6 months instead of 18 months. | 13 units | 2024-01-16 |
| Microbiologics, Inc. | UDI-DI | 2022-02-25 | Class II | Nonconforming Material/Component | Distributed product did not undergo proper release testing. | 80 units | 2024-01-16 |
Recalls
13 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-02-20 | Class II | Nonconforming Material/Component | The RSV target may give a late Ct value and could potentially not pass QC. | 28 units | |
| 2025-02-20 | Class II | Process control | The A549 human cell target (human cells for sample adequacy control) may give a late Ct value. | 6 units | |
| 2022-07-27 | Class III | Process control | Product not registered for use in the UK | 2 | 2024-08-02 |
| 2022-03-24 | Class II | Process control | QC process was not adequate for the specification range. | 1 ea | 2023-01-09 |
| 2022-03-22 | Class II | Process control | The QC process was not adequate for the specification range. | 2 ea | 2023-01-09 |
| 2021-08-20 | Class II | Material/Component Contamination | The product indicated is contaminated with a plasmid DNA that contains the target SARS-CoV-2 sequences. | 127 | 2023-01-12 |
| 2021-08-20 | Class II | Material/Component Contamination | The SARS-CoV-2 Process Control (Pellet) contains RNA transcripts that include diagnostically relevant SARS-CoV-2 targets (CDC and WHO consensus sequences). | 218 | 2023-01-12 |
| 2020-01-03 | Class II | Process control | Product 8208 Vaginal Verification Panel is a 6 pool kit and has contaminant Candida krusei in Pool 2 (subcomponent 6063). Candida krusei is an organism intended to be contained in Pool 6 of the kit. This should have no impact on patient te | 9 | 2020-09-16 |
| 2019-12-16 | Class II | Device Design | The recommended hydration fluid for the 8180 Gram-Positive Blood Culture Control Panel (Inactivated Pellet), has changed from sterile 0.85% saline or sterile blood culture media to sterile DI water or pH 7.2 phosphate buffer. | 810 | 2020-12-11 |
| 2017-06-06 | Class II | Process design | Real-time shelf life testing failed at 24 months | 1 | 2023-01-17 |
| 2017-06-06 | Class II | Process design | Real-time shelf life testing failed at 24 months | 29 units | 2023-01-17 |
| 2017-06-06 | Class II | Process design | Real-time shelf life testing failed at 24 months | 1 unit | 2023-01-17 |
| 2017-06-06 | Class II | Process design | Real-time shelf life testing failed at 24 months | 1 unit | 2023-01-17 |
| 2017-06-06 | Class II | Process design | Real-time shelf life testing failed at 24 months | 8 units | 2023-01-17 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.