Serology I Positive Control (Serology I Control +)

Serology I Postive Control is intended for use with in vitro assays for determination of antibodies to Human Immunodeficiency Virus Type 1 and 2 (HIV-1/2), antibodies to Human…

Registry build 21.09.26

Serology I Postive Control is intended for use with in vitro assays for determination of antibodies to Human Immunodeficiency Virus Type 1 and 2 (HIV-1/2), antibodies to Human T-Lymphotropic Virus Type 1 and 2 (HTLV-1/2), antibodies to Hepatitis C Virus (HCV), Hepatitis B Surface Antigen (HBsAg), IgG antibodies to Hepatitis B Core Antibodies (HBc) and IgG antibodies to Treponema pallidum. Serology I Positive Control is unassayed without target values and is suitable for use on many analysers. These controls must not be used as a substitute for the mandatory manufacturer’s kit controls provided with the assay. Serology I Positive Control is helpful in determining the precision of testing systems and in identifying sources of variation.

2manufacturers in China registered for this device type
1catalogue number
2recalls on this code

Who Else Makes It

Concentrated in Jilin (1), Guangdong (1).

Chinese manufacturers registered for FDA product code OHQ
Manufacturer City Province Registered as Device types
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Phase Scientific (Shenzhen) Company Limited Shenzhen Guangdong Repacker / relabeller 8

Record

Regulatory record for Serology I Positive Control (Serology I Control +)
Listed by Randox Laboratories Limited, United Kingdom
FDA product code OHQ
Device type Multi-Analyte Controls Unassayed
Device class Class 1
Regulation 21 CFR 862.1660
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer
Premarket notification Exempt
Record published 2020-05-11
Record revised 2020-12-21 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Storage environment temperature 2 to 8 °C

Catalogue Numbers

Catalogue numbers for Serology I Positive Control (Serology I Control +)
Catalogue number Size Status
SR10352 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Exact Diagnostics Exact Diagnostics 64
NATtrol™ Zeptometrix LLC. 54
QC Sets and Panels: Helix Elite™ Microbiologics, Inc. 51
Helix Elite™ Molecular Standards: Inactivated Standard Microbiologics, Inc. 41
Multichem S Plus Techno-Path Manufacturing Ltd. 35
Virotrol Bio-Rad Laboratories Inc. 27
Helix Elite™ Molecular Standards: Synthetic Standard Microbiologics, Inc. 25
Multichem IA Plus Techno-Path Manufacturing Ltd. 17
D3 Diagnostic Hybrids, Inc. 14
Liquichek Bio-Rad Laboratories Inc. 10
Multichem IA Techno-Path Manufacturing Ltd. 8
QC Sets and Panels: Kwik-Stik™ 2 Pack Microbiologics, Inc. 8

Showing 12 of 107. All products under Multi-Analyte Controls Unassayed

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Serology I Positive Control (Serology I Control +)
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Randox Laboratories Limited UDI-DI 2022-08-01 Class II Process change control ***Update**
:HBsAg analyte is also Non-Reactive on the Ortho Vitros analyser as well as the Beckman Coulter DxI.
Randox Serology I Positive Control will test negative (Non-Reactive) for Marker HBsAg resulting in delay in reporting patient
2 units 2024-12-13

Recalls

1 of these is Class III. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2023-11-06 Class III Process control A decrease in the reactivity of HSV Type 1/2 lgM in the Serology ToRCH lgM Positive Control when tested on the DiaSorin Liaison XL. 1 unit

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer