Atellica IM 1600 Analyzer

Atellica IM 1600 Analyzer (Refurbished)

Registry build 21.09.26
16manufacturers in China registered for this device type
2catalogue numbers in this listing
2510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Guangdong (5), Jiangsu (3), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JJE
Manufacturer City Province Registered as Device types
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Dongguan BAO Kang Dian ZI KE JI Limited Dongguan Guangdong Contract manufacturer 24
Beckman Coulter Laboratory Systems (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 4
Zhejiang Orient Gene Biotech Huzhou Zhejiang Contract manufacturer 86
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
Shenzhen Yhlo Biotech Co., Ltd. Shenzhen Guangdong Manufacturer 19
Getein Biotech, Inc. Nanjing Jiangsu Manufacturer 19
Beijing Hotgen Biotech Co., Ltd. Beijing Beijing Manufacturer 13
Yantai Addcare Bio-Tech Co., Ltd. Yantai Shandong Contract manufacturer 8
Shenzhen NEW Industries Biomedical Engineering Co., Ltd. Shenzhen Guangdong Manufacturer 4
Shanghai Kehua Laboratory System Co., Ltd. Shanghai Shanghai Manufacturer 4

Showing 12 of 16. All 16 manufacturers in China registered for Analyzer, Chemistry (Photometric, Discrete), For Clinical Use

Record

Regulatory record for Atellica IM 1600 Analyzer
Listed by Siemens Healthcare Diagnostics Inc, United States
FDA product code JJE
Device type Analyzer, Chemistry (Photometric, Discrete), For Clinical Use
Device class Class 1
Regulation 21 CFR 862.2160
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K151792
Record published 2020-09-24
Record revised 2022-09-16 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Atellica IM 1600 Analyzer
Catalogue number Size Status
11066000 In distribution
11764888 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Alinity Abbott Medical 283
Architect Abbott Laboratories 115
Alinity Abbott Laboratories 18
Biobase Biobase Biodustry(Shandong)Co., Ltd. 15
Vitros Ortho-Clinical Diagnostics, Inc. 14
Architect Abbott Ireland Diagnostics 8
AU Beckman Coulter, Inc. 7
Alinity Abbott Ireland Diagnostics 6
DxC AU Beckman Coulter, Inc. 6
Chemiluminescence Immunoassay Analyzer Shenzhen Yhlo Biotech Co., Ltd. 6
Automated Chemiluminescent Enzyme Immunoassay Analyzer AIA-CL300 Tosoh Corp. 5
Pictus 500 Clinical chemistry analyzer Diatron Medicinai Instrumentumok Laboratoriumi Diagnosztikai Fejleszto-Gyarto Zartkoruen Mukodo Reszvenytarsasag 4

Showing 12 of 336. All products under Analyzer, Chemistry (Photometric, Discrete), For Clinical Use

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K130276 2013-03-22
K112999 2011-11-22

Recalls Naming This Product

17 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.

Recalls naming the identifiers of Atellica IM 1600 Analyzer
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Siemens Healthcare Diagnostics Inc UDI-DI 2022-04-13 Class II Under Investigation by firm Lots incompatible with Test Definition (TDef) Version 1.4,
potentially lead to the generation of erroneous total T3 results
2,321
Siemens Healthcare Diagnostics Inc 510(k) number 2021-09-28 Class II Under Investigation by firm Ancillary reagent packs used on Atellica IM 1300 and Atellica IM 1600 analyzers may overflow when pierced while on an analyzer located at an altitude of greater than 350m (1148ft) above sea level. As a result, customers at these altitudes m 1193
Siemens Healthcare Diagnostics Inc 510(k) number 2021-09-28 Class II Under Investigation by firm Ancillary reagent packs used on Atellica IM 1300 and Atellica IM 1600 analyzers may overflow when pierced while on an analyzer located at an altitude of greater than 350m (1148ft) above sea level. As a result, customers at these altitudes m 1733
Siemens Healthcare Diagnostics Inc UDI-DI 2021-05-13 Class II Component design/selection Valves used on the Atellica CH 930, Atellica IM 1300 and Atellica IM 1600 analyzers may develop a malfunction due to a manufacturing defect and may result in the valve wearing and leaking over time. The leaking is a risk in valves subject t US: 123 OUS: 751
Siemens Healthcare Diagnostics Inc 510(k) number 2020-12-02 Class II Under Investigation by firm Multiple issues in Software v1.23.2 and lower-may lead to the reporting of discrepant patient results 1095 units 2024-06-06
Siemens Healthcare Diagnostics Inc 510(k) number 2020-12-02 Class II Under Investigation by firm Multiple issues in Software v1.23.2 and lower-may lead to the reporting of discrepant patient results 1588 units 2024-06-06
Siemens Healthcare Diagnostics Inc UDI-DI 2020-10-26 Class II Under Investigation by firm Test Definition scanning may reset custom settings to defaults. When a 2D Master Curve and TDef barcode for a new kit lot of reagent is scanned and the TDef version is a newer version than the version that is currently on the system, some o US: 214 units; OUS: 1082 units 2024-04-19
Siemens Healthcare Diagnostics Inc 510(k) number 2020-05-07 Class II Employee error Insufficient sample may not be detected when using Tube Top Sample Cup (TTSC) or V-shaped Sample Cup sample containers with the Atellica IM1300 and IM1600 analyzers. 927
Siemens Healthcare Diagnostics Inc 510(k) number 2020-05-07 Class II Employee error Insufficient sample may not be detected when using Tube Top Sample Cup (TTSC) or V-shaped Sample Cup sample containers with the Atellica IM1300 and Atellica IM1600 analyzers. 1329
Siemens Healthcare Diagnostics Inc 510(k) number 2019-08-15 Class II Under Investigation by firm Issues Scanning New Reagent Lot Test Definition on the Atellica IM 1300 Analyzer and Atellica IM 1600 Analyzer
SW V 1.19.0 and 1.19.2
88 total US: 54;OUS 34 2022-05-05
Siemens Healthcare Diagnostics Inc 510(k) number 2019-08-15 Class II Under Investigation by firm Issues Scanning New Reagent Lot Test Definition on the Atellica IM 1300 Analyzer and Atellica IM 1600 Analyzer
SW V 1.19.0 and 1.19.2
166 total US: 15; OUS:151 2022-05-05
Siemens Healthcare Diagnostics Inc UDI-DI 2019-03-07 Class II Under Investigation by firm There were multiple issues identified in the system software which required an update. 366 2020-08-20
Siemens Healthcare Diagnostics Inc UDI-DI 2019-03-07 Class II Under Investigation by firm There were multiple issues identified in the system software which required an update. 474 2020-08-20
Siemens Healthcare Diagnostics Inc 510(k) number 2018-06-29 Class II Software design Atellica Solution system software (SW) version 1.13 and lower, five (5) behavioral issues were identified:
1. Reagent Lock may not work as intended with Primary Reagent ReadyPacks and Ancillary Packs when more than one (1) lot of specific R
45 2021-08-12
Siemens Healthcare Diagnostics Inc 510(k) number 2018-06-29 Class II Software design Atellica Solution system software (SW) version 1.13 and lower, five (5) behavioral issues were identified:
1. Reagent Lock may not work as intended with Primary Reagent ReadyPacks and Ancillary Packs when more than one (1) lot of specific R
92 2021-08-12
Siemens Healthcare Diagnostics Inc 510(k) number 2018-02-26 Class II Software design When more than one immunoassay analyzer is connected to a single solution system, reporting and conversion factors may not be applied to all analyzers 2020-05-12
Siemens Healthcare Diagnostics Inc 510(k) number 2018-02-26 Class II Software design When more than one immunoassay analyzer is connected to a single solution system, reporting and conversion factors may not be applied to all analyzers 2020-05-12

Recalls

27 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-05-22 Class II Under Investigation by firm Contamination of the diluent by sodium hypochlorite (NaOCl) which may impact calibrator, quality control (QC), and patient results for all assays except for sodium, potassium, and chloride. 1,625 units (1450 US, 175 OUS)
2024-11-04 Class II Software design Potential that the IMT Diluent volume remaining (% remaining) does not decrease as expected on the Atellica CI Analyzer, potentially leading to the IMT Diluent being empty while still displaying that volume is remaining. In this case Sodiu 559 units
2024-10-21 Class II Under Investigation by firm A manufacturing defect causes Atellica CH Reaction Ring Cuvette Segments with lot numbers N15 on the packaging or 15 on the underside of the cuvette segment have a potential for imprecision and erroneously depressed or elevated QC and patie 9729 units
2023-05-16 Class II Under Investigation by firm A firmware error may lead to an incorrect association of test result(s) to a sample ID and therefore to an incorrect patient result.

The mis-association of test results, or a delay in testing, may occur when all the conditions listed belo

83 units
2021-10-15 Class II Software design Incorrect Default Hemolysis, Icterus or Lipemia (HIL) Index for Five Dimension Vista Assays 1326 units 2024-05-13
2021-10-15 Class II Software design Incorrect Default Hemolysis, Icterus or Lipemia (HIL) Index for Five Dimension Vista Assays 1407 units 2024-05-13
2020-05-15 Class II Nonconforming Material/Component Flexible tubing connected to the liquid waste bottle can crack during routine customer maintenance potentially
causing liquid waste can leak onto the floor, creating a slip and fall hazard
2925 units 2022-08-12
2020-05-15 Class II Nonconforming Material/Component Flexible tubing connected to the liquid waste bottle can crack during routine customer maintenance potentially
causing liquid waste can leak onto the floor, creating a slip and fall hazard
1555 units 2022-08-12
2019-09-23 Class II Software design Potential for calibration error resulting in QC failures after the calibration run with QC and patient results being 5 times higher. 1432 2022-07-06
2018-12-12 Class II Under Investigation by firm When the Millipore Water Purification Module Progard Pretreatment Packs are used with Dimension Vista Triglyceride assay, patient and QC triglyceride results may be erroneously elevated as a result of contamination. 5373 2020-04-27
2018-12-12 Class II Under Investigation by firm When the Millipore Water Purification Module Progard Pretreatment Packs are used with Dimension Vista Triglyceride assay, patient and QC triglyceride results may be erroneously elevated as a result of contamination. 5373 2020-04-27
2018-10-16 Class II Under Investigation by firm Siemens Healthcare Diagnostics has identified an issue with Dimension Vista software v.3.7 and v.3.8.1 that may result in aliquot well contamination.
If a test is cancelled by the operator while the instrument is aliquotting the sample, the
1628 2020-06-17
2018-10-16 Class II Under Investigation by firm Siemens Healthcare Diagnostics has identified an issue with Dimension Vista software v.3.7 and v.3.8.1 that may result in aliquot well contamination.
If a test is cancelled by the operator while the instrument is aliquotting the sample, the
1649 2020-06-17
2018-09-28 Class II Device Design Thermal chamber motors have electrical cables with single insulation rather than the required double insulation. There is no exposed current due to the single insulation that could result in a potential electrical shock 277 units 2020-06-17
2018-06-29 Class II Software design Atellica Solution system software (SW) version 1.13 and lower, five (5) behavioral issues were identified:
1. Reagent Lock may not work as intended with Primary Reagent ReadyPacks and Ancillary Packs when more than one (1) lot of specific R
35 2021-08-12
2018-06-29 Class II Software design Atellica Solution system software (SW) version 1.13 and lower, five (5) behavioral issues were identified:
1.

Reagent Lock may not work as intended with Primary Reagent ReadyPacks and Ancillary Packs when more than one (1) lot of specific R

107 2021-08-12
2018-06-29 Class II Software design Atellica Solution system software (SW) version 1.13 and lower, five (5) behavioral issues were identified:
1. Reagent Lock may not work as intended with Primary Reagent ReadyPacks and Ancillary Packs when more than one (1) lot of specific R
5 2021-08-12
2018-06-29 Class II Software design Atellica Solution system software (SW) version 1.13 and lower, five (5) behavioral issues were identified:
1. Reagent Lock may not work as intended with Primary Reagent ReadyPacks and Ancillary Packs when more than one (1) lot of specific R
115 2021-08-12
2017-03-03 Class II Under Investigation by firm Siemens Healthcare Diagnostics has confirmed that in isolated cases when ECREA is processed immediately after the weekly automated Acid Clean routine during Probe Test, there is the remote potential for an elevation of greater than 15 perce 2733 systems 2018-07-03
2017-02-02 Class II Under Investigation by firm Multiple software issues, which may affect the operation and workflow of the system.

Potential for an apparent delay to testing when these issues occur. The software issues affecting the analyzer may impact all analytes available on the ADV

US: 17 units; Foreign: 712 units 2018-06-22
2016-09-29 Class II Under Investigation by firm 448 units 2018-09-19
2016-09-29 Class II Under Investigation by firm Possible overheating of power cord plugs used to connect to FlexLab and Aptio Automation systems. 448 units 2018-09-19
2016-03-30 Class III Use error The firm identified an issue in sample processing when using EZee-Nest Insert Cups due to two inaccuracies that exist in the ADVIA Centaur CP Operators Guide. US: 442 units; Foreign: 3237 units 2017-03-29
2016-03-24 Class II Software design Discrepant patient results on Dimension Vista Intelligent Lab Systems. Siemens Healthcare confirmed a software defect which, in a very specific set of circumstances, results in the Dimension Vista System omitting an aliquot probe rinse bet 1300 2017-03-13
2016-03-24 Class II Software design Discrepant patient results on Dimension Vista Intelligent Lab Systems.

Siemens Healthcare confirmed a software defect which, in a very specific set of circumstances, results in the Dimension Vista System omitting an aliquot probe rinse bet

1301 units 2017-03-13
2015-11-10 Class II Nonconforming Material/Component Siemens has
identified RMS refrigeration compressors that are missing the safety cover on the electrical
termination block. The exposed electrical hazard on the electrical termination block is located
directly behind the RMS Waste Container
3 2017-08-23
2015-11-10 Class II Nonconforming Material/Component Siemens has
identified RMS refrigeration compressors that are missing the safety cover on the electrical
termination block. The exposed electrical hazard on the electrical termination block is located
directly behind the RMS Waste Container
151 2017-08-23
2015-11-10 Class II Nonconforming Material/Component Siemens has
identified RMS refrigeration compressors that are missing the safety cover on the electrical
termination block.

The exposed electrical hazard on the electrical termination block is located
directly behind the RMS Waste Container

106 2017-08-23

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA.

Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer