Cobas 6000 Core Unit

Catalogue number 07354436001, listed by Roche Diagnostics Gmbh, Germany, under Analyzer, Chemistry (Photometric, Discrete), For Clinical Use. 16 manufacturers in China are registered for this product code.

Registry build 21.09.26
16manufacturers in China registered for this device type
1catalogue number
40recalls on this code

Who Else Makes It

Concentrated in Guangdong (5), Jiangsu (3), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JJE
Manufacturer City Province Registered as Device types
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Dongguan BAO Kang Dian ZI KE JI Limited Dongguan Guangdong Contract manufacturer 24
Beckman Coulter Laboratory Systems (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 4
Zhejiang Orient Gene Biotech Huzhou Zhejiang Contract manufacturer 86
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
Shenzhen Yhlo Biotech Co., Ltd. Shenzhen Guangdong Manufacturer 19
Getein Biotech, Inc. Nanjing Jiangsu Manufacturer 19
Beijing Hotgen Biotech Co., Ltd. Beijing Beijing Manufacturer 13
Yantai Addcare Bio-Tech Co., Ltd. Yantai Shandong Contract manufacturer 8
Shenzhen NEW Industries Biomedical Engineering Co., Ltd. Shenzhen Guangdong Manufacturer 4
Shanghai Kehua Laboratory System Co., Ltd. Shanghai Shanghai Manufacturer 4

Showing 12 of 16. All 16 manufacturers in China registered for Analyzer, Chemistry (Photometric, Discrete), For Clinical Use

Record

Regulatory record for cobas 6000 Core Unit
Listed by Roche Diagnostics Gmbh, Germany
FDA product code JJE
Device type Analyzer, Chemistry (Photometric, Discrete), For Clinical Use
Device class Class 1
Regulation 21 CFR 862.2160
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K060373
Record published 2015-06-19
Record revised 2022-09-16 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for cobas 6000 Core Unit
Catalogue number Size Status
07354436001 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Alinity Abbott Medical 283
Architect Abbott Laboratories 115
Alinity Abbott Laboratories 18
Biobase Biobase Biodustry(Shandong)Co., Ltd. 15
Vitros Ortho-Clinical Diagnostics, Inc. 14
Architect Abbott Ireland Diagnostics 8
AU Beckman Coulter, Inc. 7
Alinity Abbott Ireland Diagnostics 6
DxC AU Beckman Coulter, Inc. 6
Chemiluminescence Immunoassay Analyzer Shenzhen Yhlo Biotech Co., Ltd. 6
Automated Chemiluminescent Enzyme Immunoassay Analyzer AIA-CL300 Tosoh Corp. 5
Pictus 500 Clinical chemistry analyzer Diatron Medicinai Instrumentumok Laboratoriumi Diagnosztikai Fejleszto-Gyarto Zartkoruen Mukodo Reszvenytarsasag 4

Showing 12 of 336. All products under Analyzer, Chemistry (Photometric, Discrete), For Clinical Use

Recalls Naming This Product

8 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of cobas 6000 Core Unit
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Roche Diagnostics Operations 510(k) number 2019-07-18 Class II Device Design Quality issue with high pressure solenoid valves may cause inaccurate results. 1 unit 2020-06-15
Roche Diagnostics Gmbh 510(k) number 2017-12-18 Class II Labeling False and Misleading Complaints have been received concerning questionable results on analyzers due to customers utilizing 13 sample tubes without tube adapters. 2019-04-09
Roche Diagnostics Gmbh 510(k) number 2017-07-18 Class II Device Design A warning is being added to the cobas 6000 MODULAR Series System – c501 and the cobas 8000 MODULAR Analyzer Series – c502 Operator Manuals to prevent operator injury during maintenance. 3433 2018-07-13
Roche Diagnostics Gmbh 510(k) number 2017-06-29 Class II Software design Roche has confirmed that a possible sample mismatch issue may occur on the MODULAR ANALYTICS E 170 module, cobas e 601 analyzer, or cobas e 602 analyzer due to a software limitation. 2517 2020-01-24
Roche Diagnostics Gmbh 510(k) number 2017-03-21 Class II Component change control Due to a design change in 2015, corrosion on the sample probe electrical contacts can occur and lead to a disturbance of the sample liquid level detection (LLD). When disturbance of the sample liquid level detection (LLD) occurs, the affect 3946 2017-10-02
Roche Diagnostics Operations 510(k) number 2016-07-15 Class II Device Design Roche has received four reports of injury caused by the sharp edge of the center guide rail of an
analyzers sample rack tray. The cleaning procedure for the sample rack tray has been revised to clarify the cleaning process.
9014 in total 2017-06-05
Roche Diagnostics Operations 510(k) number 2014-05-21 Class II Labeling design Under certain conditions loose ProCell/CleanCell aspiration tube filters may cause: consecutive discrepant results; sipper alarm; foam on reservoirs and system reagent alarms. 1147 2015-06-04
Roche Diagnostics Operations 510(k) number 2014-05-21 Class II Labeling design Under certain conditions loose ProCell/CleanCell aspiration tube filters may cause: consecutive discrepant results; sipper alarm; foam on reservoirs and system reagent alarms. 149 2015-06-04

Recalls

10 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-03-15 Class II Device Design The firm has confirmed complaints regarding signal drops on the cobas e 801 module after a ProCell II M bottle changeover, which may lead to incorrect medical decisions with respect to diagnostics and patient treatment. 149 2020-04-23
2018-12-14 Class II Device Design COBAS INTEGRA 400 plus and cobas c 111 analyzers Additional Extra Wash Cycle Configurations and/or Batch Mode Needed for Specific Tests
Due to Carry-over
656 units 2020-09-04
2018-12-14 Class II Device Design COBAS INTEGRA 400 plus and cobas c 111 analyzers Additional Extra Wash Cycle Configurations and/or Batch Mode Needed for Specific Tests
Due to Carry-over
137 units 2020-09-04
2018-04-03 Class II Process design The syringe plunger on the device may be mounted in a tilted position, which applies mechanical stress to the plunger. In the worst case scenario, the plunger may crack leading to impaired syringe function. 35 2019-11-21
2017-12-18 Class II Labeling False and Misleading Complaints have been received concerning questionable results on analyzers due to customers utilizing 13 mm sample tubes without tube adapters. 2019-04-09
2017-12-18 Class II Labeling False and Misleading Complaints have been received concerning questionable results on analyzers due to customers utilizing sample 13 mm tubes without tube adapters. 2019-04-09
2017-07-28 Class II Device Design A software failure may incorrectly set the system settings to “default” settings, creating a risk of incorrect results. 399 2020-06-10
2017-07-18 Class II Device Design A warning is being added to the cobas 6000 analyzer and the cobas 8000 modular analyzer series Operators Manual to prevent operator injury during maintenance. 245 2018-07-13
2017-07-05 Class II Software design A software malfunction can occur on the cobas e 411 and Elecsys 2010 analyzers in the Sample& Control data file which may lead to a potential data mismatch. 255 instruments 2019-04-30
2017-07-05 Class II Software design A software malfunction can occur on the cobas e 411 and Elecsys 2010 analyzers in the Sample& Control data file which may lead to a potential data mismatch. 923 instruments 2019-04-30
2008-11-17 Not classified Nonconforming Material/Component Due to a manufacturing error at the supplier, not all cobas c 111 pinch valve caps are properly glued to the correct position on the pinch valve shaft. Without the glue, the cap can become loose or misaligned. The effect of these faulty val 66 2009-12-08
2008-11-12 Not classified Software change control If a masked module is unmasked during the reagent registration process, the calibration parameters may be assigned to the wrong reagents, resulting in the reporting of incorrect control and sample results. 22 systems in all 2009-09-22
2008-11-12 Not classified Software change control If a masked module is unmasked during the reagent registration process, the calibration parameters may be assigned to the wrong reagents, resulting in the reporting of incorrect control and sample results. 22 systems in all 2009-09-22
2008-11-12 Not classified Software change control If a masked module is unmasked during the reagent registration process, the calibration parameters may be assigned to the wrong reagents, resulting in the reporting of incorrect control and sample results. 22 systems in all 2009-09-22
2008-11-12 Not classified Software change control If a masked module is unmasked during the reagent registration process, the calibration parameters may be assigned to the wrong reagents, resulting in the reporting of incorrect control and sample results. 22 systems in all 2009-09-22
2008-06-24 Not classified Other A software bug may result in pipetting from an incorrect reagent pack and/or assigning calibration curve parameters incorrectly. 2009-10-22
2008-03-21 Not classified Process change control Possible mismatch between patient and result. 11 of all models 2009-11-18
2008-03-21 Not classified Process change control Possible mismatch between patient and result. 11 of all models 2009-11-18
2008-03-21 Not classified Process change control Possible mismatch between patient and result. 11 of all models 2009-11-18
2008-03-21 Not classified Process change control Possible mismatch between patient and result. 11 of all models. 2009-11-18
2008-03-21 Not classified Process change control Possible mismatch between patient and result. 11 of all models 2009-11-18
2004-08-06 Not classified Other A software defect will allow the reporting out of believable, but clinically significant, erroneous results under certain conditions. 2006-06-26
2004-08-06 Not classified Other A software defect will allow the reporting out of believable, but clinically significant, erroneous results under certain conditions. 2006-06-26
2004-08-06 Not classified Other A software defect will allow the reporting out of believable, but clinically significant, erroneous results if the analyzer is in operation and a channel has been masked or not requested over a period of time. 254 2006-06-26
2004-08-06 Not classified Other A software defect will allow the reporting out of believable, but clinically significant, erroneous results under certain conditions. 138 2006-06-26
2004-08-06 Not classified Other A software defect will allow the reporting out of believable, but clinically significant, erroneous results under certain conditions. 2006-06-26
2003-12-29 Not classified Other The firm is withdrawing claims that pleural, pericardial, ascitic and cerebrospinal fluids are appropriate sample types for use on these instruments. 2004-02-20
2003-12-29 Not classified Other The firm is withdrawing claims that pleural, pericardial, ascitic and cerebrospinal fluids are appropriate sample types for use on these instruments. 2004-02-20
2003-12-29 Not classified Other The firm is withdrawing claims that pleural, pericardial, ascitic and cerebrospinal fluids are appropriate sample types for use on these instruments. 2004-02-20
2003-12-29 Not classified Other The firm is withdrawing claims that pleural, pericardial, ascitic and cerebrospinal fluids are appropriate sample types for use on these instruments. 2004-02-20
2003-12-29 Not classified Other The firm is withdrawing claims that pleural, pericardial, ascitic and cerebrospinal fluids are appropriate sample types for use on these instruments. 2004-02-20
2003-12-29 Not classified Other The firm is withdrawing claims that pleural, pericardial, ascitic and cerebrospinal fluids are appropriate sample types for use on these instruments. 2004-02-20
2003-12-29 Not classified Other The firm is withdrawing claims that pleural, pericardial, ascitic and cerebrospinal fluids are appropriate sample types for use on these instruments. 2004-02-20
2003-12-29 Not classified Other The firm is withdrawing claims that pleural, pericardial, ascitic and cerebrospinal fluids are appropriate sample types for use on these instruments. 2004-02-20
2003-12-29 Not classified Other The firm is withdrawing claims that pleural, pericardial, ascitic and cerebrospinal fluids are appropriate sample types for use on these instruments. 2004-02-20
2003-12-15 Not classified Other If the sample volume is insufficient, the analyzer may issue erroneous results without any indication to the user that the problem is insufficient sample volume. 2004-08-02

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer