V-Twin®

Catalogue number 6002-800, listed by VitalScientific B.V., Netherlands, under Analyzer, Chemistry, Micro, For Clinical Use. 3 manufacturers in China are registered for this product code.

Registry build 21.09.26
3manufacturers in China registered for this device type
1catalogue number
1recall

Who Else Makes It

Concentrated in Jiangsu (1), Hubei (1), Henan (1).

Chinese manufacturers registered for FDA product code JJF
Manufacturer City Province Registered as Device types
Getein Biotech, Inc. Nanjing Jiangsu Manufacturer 19
Wuhan Landing Intelligence Medical Co., Ltd. Wuhan Hubei Manufacturer 17
Autobio Labtec Instruments Co., Ltd. Zhengzhou Henan Manufacturer 3

Record

Regulatory record for V-Twin®
Listed by VitalScientific B.V., Netherlands
FDA product code JJF
Device type Analyzer, Chemistry, Micro, For Clinical Use
Device class Class 1
Regulation 21 CFR 862.2170
Establishment Contract manufacturer, Manufacturer
Record published 2016-11-21
Record revised 2025-05-07 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries manufacturing date, serial number
Distribution end date 2025-05-06

Catalogue Numbers

Catalogue numbers for V-Twin®
Catalogue number Size Status
6002-800 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Diamedix Diamedix Corp. 2
Spotcheck Astoria-Pacific, Inc. 2
Cholestech LDX™ Alere San Diego, Inc. 2
AWS Randox Laboratories Limited 1
Liaison® XL Diasorin Inc. 1
COBAS®TaqMan® 48 Analyzer Roche Molecular Systems, Inc. 1
Soln Wash Randox Laboratories Limited 1
Wash conc. 1 Randox Laboratories Limited 1
NS Randox Laboratories Limited 1
Liaison® Easy Starter Kit Diasorin S.P.A 1
Rabs Randox Laboratories Limited 1
Cl Soln Randox Laboratories Limited 1

Showing 12 of 26. All products under Analyzer, Chemistry, Micro, For Clinical Use

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-09-07 Class II Device Design The action is being initiated because the cooling indicator board was improperly installed. This was first noticed by a service employee during assembly. If for some reason the cooling of the reagent rotor fails, the reagent cooling indica 192 devices 2022-06-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer