QIAamp DSP Circulating DNA Kit

QIAamp DSP Circulating DNA Kit: 1 catalogue number listed by Qiagen, Gmbh, Germany, under Clinical Sample Concentrator. 27 manufacturers in China are registered for this product code.

Registry build 21.09.26
27manufacturers in China registered for this device type
1catalogue number
7recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Zhejiang (6), Guangdong (4). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code JJH
Manufacturer City Province Registered as Device types
Zhejiang Orient Gene Biotech Huzhou Zhejiang Contract manufacturer 86
Boen Healthcare Co., Ltd. Suzhou Jiangsu Specification developer 263
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70
Guangzhou Four E’s Scientific Co., Ltd. Guangzhou Guangdong Contract manufacturer 61
Nanning Tecbod Biological Technology Co., Ltd. Nanning Guangxi Contract manufacturer 51
Zhejiang Gene Science Co., Ltd. Shaoxing Zhejiang Manufacturer 31
Biomed Plastics Co. Taicang Jiangsu Contract manufacturer 29
Bioteke Corporation (Wuxi) Co., Ltd. Wuxi Jiangsu Manufacturer 21
Changsha Renji Medical Equipment Co., Ltd. Changsha Hunan Manufacturer 15
Jiangsu Macro & Micro-Test MED-Tech Co., Ltd. Nantong Jiangsu Manufacturer 11
Phase Scientific (Shenzhen) Company Limited Shenzhen Guangdong Repacker / relabeller 8
Xian Tianlong Science AND Technology Co., Ltd. Xi’An Shaanxi Manufacturer 8

Showing 12 of 27. All 27 manufacturers in China registered for Clinical Sample Concentrator

Record

Regulatory record for QIAamp DSP Circulating DNA Kit
Listed by Qiagen, Gmbh, Germany
FDA product code JJH
Device type Clinical Sample Concentrator
Device class Class 1
Regulation 21 CFR 862.2310
Establishment Contract manufacturer, Specification developer, Manufacturer, Exporter
Premarket notification Exempt
Record published 2017-08-15
Record revised 2018-03-29 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for QIAamp DSP Circulating DNA Kit
Catalogue number Size Status
1 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
TANBead Nucleic Acid Extraction Kit Taiwan Advanced Nanotech Inc. 124
PCRopsis Entopsis, Inc. 53
Bioer MagaBio plus Virus DNA /RNA Purification Kit III Hangzhou Bioer Technology Co., Ltd. 20
m2000 Abbott Molecular, Inc. 19
Allsheng Hangzhou Allsheng Instruments Co., Ltd. 13
TANBead Nucleic Acid Extractor Taiwan Advanced Nanotech Inc. 12
Bioer MagaBio plus Virus RNA Purification Kit II Hangzhou Bioer Technology Co., Ltd. 10
Biobase Biobase Biodustry(Shandong)Co., Ltd. 9
BioTeke Bioteke Corporation (Wuxi) Co., Ltd. 8
Prochem Vivaproducts, Inc. 8
Vivafree 500 Sartorius Stedim Lab Ltd. 6
Amicon Ultra → 4 Merck Millipore Ltd. 6

Showing 12 of 268. All products under Clinical Sample Concentrator

Recalls

1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-06-03 Class II Software design Heater shaker module does not perform heating if the temperature is set below 40C for static incubation steps when running IVD protocol QIAamp DSP DNA Mini Kit (cat. no. 61304), Protocol: Isolation of genomic DNA from Gram-positive bacteria 419 units
2024-03-04 Class II Under Investigation by firm Insufficient welding leads to the heater cable becoming brittle and present with an error:
ERROR 3481 HEATER UNABLE TO REACH TEMPERATURE; the instrument may stop, and the sample being processed will be lost
168 units: 38 units US; 130 units OUS
2021-11-21 Class II Other During the “Load tip racks and enzymes” step of the run set-up, the info screen indicates “minimal volume to be loaded”, but the indicated volume is instead the exact volume that should be loaded. Misunderstanding the guidance may lead to o 93 US; 57 OUS
2019-07-02 Class II Software design QIAsymphony software version 5.0.3 – Software issue
incorreclty assigns the 2D bar code eluate ID to the sample within the results file. If 2D bar code eluate IDs are not checked against the sample ID prior to downstream
application the inc
417
2019-06-05 Class I Process control Kit lots contain a small percentage of damaged Filter-Tips that are leaking when being used with the QIAsymphony SP/AS Instruments (REF 9001297 and 9001301) 1240 Kits 2020-08-28
2018-07-23 Class II Nonconforming Material/Component An issue with the power branching printed circuit board (PCB) on the instrument that has the potential to trigger a heater malfunction was discovered. If this failure were to occur, nucleic acid extractions could be compromised and extracti 298 2020-06-05
2018-05-28 Class II Under Investigation by firm Underfilled reagent well that could lead to incorrect results 287 pcs 2019-04-05

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer