AutoDELFIA Plate Processor
Used with 1235-5110 AutoDELFIA® Plate Processor System or 1235-5220 AutoDELFIA® System (SP and PP).
Who Else Makes It
Concentrated in Beijing (1), Zhejiang (1), Jiangsu (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| W.h.p.m. Bioresearch & Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 37 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
| Jiangsu Macro & Micro-Test MED-Tech Co., Ltd. | Nantong | Jiangsu | Manufacturer | 11 |
| Yantai Addcare Bio-Tech Co., Ltd. | Yantai | Shandong | Contract manufacturer | 8 |
| Guangzhou Labsim Biotech Co., Ltd. | Guangzhou | Guangdong | Manufacturer | 3 |
Record
| Listed by | Wallac OY, Finland |
|---|---|
| FDA product code | KHO |
| Device type | Fluorometer, For Clinical Use |
| Device class | Class 1 |
| Regulation | 21 CFR 862.2560 |
| Establishment | Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2016-07-01 |
| Record revised | 2022-09-16 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1235-0110 | In distribution | |
| 1235-001 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Sofia | Quidel Corp. | 4 |
| Vitros | Ortho-Clinical Diagnostics, Inc. | 3 |
| Victor EnLite | Wallac OY | 2 |
| AutoDELFIA Automatic Immunoassay System | Wallac OY | 2 |
| Fluorometer, For Clinical Use | Guangzhou Labsim Biotech Co., Ltd. | 2 |
| Macro & Micro-Test Fluorescence Immunoassay Analyzer | Jiangsu Macro & Micro-Test MED-Tech Co., Ltd. | 2 |
| AutoDELFIA Sample processor | Wallac OY | 2 |
| Asfa® Scanner | MBD Co., Ltd. | 2 |
| VICTOR2 D | Wallac OY | 2 |
| Seeker™ | Baebies Inc. | 2 |
| Frend System | Nanoentek Inc | 2 |
| Carolina Liquid Chemistries Corp. Immunofluorescence Analyzer Ryan | Carolina Liquid Chemistries | 1 |
Showing 12 of 34. All products under Fluorometer, For Clinical Use
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K935047 | 1994-05-23 |
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| PerkinElmer Health Sciences, Inc. | UDI-DI | 2016-12-21 | Class III | Software design | AutoDELFIA System with Version 3.0 Software: Potential plate loading failures | 1 unit (US) 6 (OUS) | 2018-10-03 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2017-01-05 | Class II | Component change control | The firm became aware that the ball bushing axels are defective in the GSP instrument. During exposure to humid conditions, there is a risk that the axle material will corrode. Deterioration of the axle can be observed as deposits of corros | 24 instruments and 3 spare disk remover modules | 2017-08-24 |
| 2017-01-05 | Class II | Component change control | The firm became aware that the ball bushing axels are defective in the GSP instrument. During exposure to humid conditions, there is a risk that the axle material will corrode. Deterioration of the axle can be observed as deposits of corros | 24 instruments and 3 spare disk remover modules | 2017-08-24 |
| 2012-01-09 | Not classified | Nonconforming Material/Component | GSP instruments with defective washer modules may cause a false negative screening result being reported for T4, TSH and IRT. For 17-OHP, a false positive result may be generated if the failure occurs for a normal sample. | 10 units | 2013-03-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.