AutoDELFIA Sample Processor
Used with 1235-5220 AutoDELFIA® System (SP and PP).
5manufacturers in China registered for this device type
2catalogue numbers in this listing
1510(k) clearance
3recalls on this code
Who Else Makes It
Concentrated in Beijing (1), Zhejiang (1), Jiangsu (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| W.h.p.m. Bioresearch & Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 37 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
| Jiangsu Macro & Micro-Test MED-Tech Co., Ltd. | Nantong | Jiangsu | Manufacturer | 11 |
| Yantai Addcare Bio-Tech Co., Ltd. | Yantai | Shandong | Contract manufacturer | 8 |
| Guangzhou Labsim Biotech Co., Ltd. | Guangzhou | Guangdong | Manufacturer | 3 |
Record
| Listed by | Wallac OY, Finland |
|---|---|
| FDA product code | KHO |
| Device type | Fluorometer, For Clinical Use |
| Device class | Class 1 |
| Regulation | 21 CFR 862.2560 |
| Establishment | Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2016-07-01 |
| Record revised | 2022-09-16 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1297-0110 | In distribution | |
| 1297-014 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Sofia | Quidel Corp. | 4 |
| Vitros | Ortho-Clinical Diagnostics, Inc. | 3 |
| AutoDELFIA Plate processor | Wallac OY | 2 |
| Victor EnLite | Wallac OY | 2 |
| AutoDELFIA Automatic Immunoassay System | Wallac OY | 2 |
| Fluorometer, For Clinical Use | Guangzhou Labsim Biotech Co., Ltd. | 2 |
| Macro & Micro-Test Fluorescence Immunoassay Analyzer | Jiangsu Macro & Micro-Test MED-Tech Co., Ltd. | 2 |
| Asfa® Scanner | MBD Co., Ltd. | 2 |
| VICTOR2 D | Wallac OY | 2 |
| Seeker™ | Baebies Inc. | 2 |
| Frend System | Nanoentek Inc | 2 |
| Carolina Liquid Chemistries Corp. Immunofluorescence Analyzer Ryan | Carolina Liquid Chemistries | 1 |
Showing 12 of 34. All products under Fluorometer, For Clinical Use
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K935047 | 1994-05-23 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2017-01-05 | Class II | Component change control | The firm became aware that the ball bushing axels are defective in the GSP instrument. During exposure to humid conditions, there is a risk that the axle material will corrode. Deterioration of the axle can be observed as deposits of corros | 24 instruments and 3 spare disk remover modules | 2017-08-24 |
| 2017-01-05 | Class II | Component change control | The firm became aware that the ball bushing axels are defective in the GSP instrument. During exposure to humid conditions, there is a risk that the axle material will corrode. Deterioration of the axle can be observed as deposits of corros | 24 instruments and 3 spare disk remover modules | 2017-08-24 |
| 2012-01-09 | Not classified | Nonconforming Material/Component | GSP instruments with defective washer modules may cause a false negative screening result being reported for T4, TSH and IRT. For 17-OHP, a false positive result may be generated if the failure occurs for a normal sample. | 10 units | 2013-03-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.