Verigene® Processor SP
The Verigene® Processor SP is an instrument which integrates sample preparation, target amplification, and target hybridization within a single device as part of the Verigene® System, a…
The Verigene® Processor SP is an instrument which integrates sample preparation, target amplification, and target hybridization within a single device as part of the Verigene® System, a benchtop molecular diagnostics workstation that utilizes patented gold nanoparticle technology to detect nucleic acid targets of interest for a variety of applications.
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (2), Shandong (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Hochuen Medical Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 20 |
| Biobase Biodustry(Shandong)Co., Ltd. | Jinan | Shandong | Manufacturer | 70 |
| Shenzhen Yhlo Biotech Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 19 |
| Wuhan Landing Intelligence Medical Co., Ltd. | Wuhan | Hubei | Manufacturer | 17 |
| Jiangsu Macro & Micro-Test MED-Tech Co., Ltd. | Nantong | Jiangsu | Manufacturer | 11 |
| Xian Tianlong Science AND Technology Co., Ltd. | Xi’An | Shaanxi | Manufacturer | 8 |
| Xiamen Zeesan Biotech Co., Ltd. | Xiamen | Fujian | Manufacturer | 6 |
| Jiangsu Bioperfectus Technologies Co., Ltd. | Taizhou | Jiangsu | Manufacturer | 3 |
| Shanghai ZJ BIO-Tech Co., Ltd. | Shanghai | Shanghai | Private-label distributor | 3 |
Record
| Listed by | Luminex Corporation, United States |
|---|---|
| FDA product code | NSU |
| Device type | Instrumentation For Clinical Multiplex Test Systems |
| Device class | Class 2 |
| Regulation | 21 CFR 862.2570 |
| Establishment | Contract manufacturer, Remanufacturer, Complaint-file establishment, Manufacturer |
| Record published | 2019-12-05 |
| Record revised | 2022-09-16 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Storage | Storage environment temperature -20 to 60 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10-0000-07 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Spartan RX CYP2C19 System | Spartan Bioscience, Inc. | 10 |
| BioPlex 2200 | Bio-Rad Laboratories Inc. | 8 |
| Aptima® | Hologic, Inc. | 7 |
| OpsisDx | Entopsis, Inc. | 5 |
| Affymetrix | Affymetrix, Inc. | 4 |
| FilmArray® 2.0 Instrument Ngds Configuration | BioFire Defense, LLC | 3 |
| FilmArray® 2.0 Instrument | BioFire Diagnostics, LLC | 3 |
| Opus | Bio-Rad Laboratories Inc. | 3 |
| FilmArray® Torch System Base | BioFire Diagnostics, LLC | 3 |
| FilmArray® Torch Module | BioFire Diagnostics, LLC | 3 |
| Biofire ® Spotfire ® Module | BioFire Diagnostics, LLC | 2 |
| Biofire ® Spotfire ® Control Station | BioFire Diagnostics, LLC | 2 |
Showing 12 of 110. All products under Instrumentation For Clinical Multiplex Test Systems
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K133302 | 2014-01-10 |
| K121399 | 2013-01-09 |
| K073506 | 2008-03-07 |
Recalls Naming This Product
6 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Luminex Corporation | UDI-DI | 2021-03-18 | Class II | Process control | Potential for a false-negative result for Vibrio parahaemolyticus, Salmonella, and/or Shigella spp when used with the VERIGENE Enteric Pathogens Nucleic Acid Test Kit. | 1210 Units | |
| Luminex Corporation | UDI-DI | 2020-10-13 | Class II | Nonconforming Material/Component | Luminex has determined that three (3) separate test fixtures used by field service engineers to service the VERIGENE SP Processors were procured from unapproved sources and, in some cases, were manufactured using unvalidated processes. The | 2838 units | 2024-01-22 |
| Luminex Corporation | UDI-DI | 2020-10-13 | Class II | Nonconforming Material/Component | Luminex has determined that three (3) separate test fixtures used by field service engineers to service the VERIGENE SP Processors were procured from unapproved sources and, in some cases, were manufactured using unvalidated processes. The | 2838 units | 2024-01-22 |
| Luminex Corporation | UDI-DI | 2020-06-15 | Class II | Device Design | An instrument failure mode that may result in a Blood Culture Gram Positive (BC-GP) or Gram Negative (BC-GN) false negative call. | Total = 3,016 systems (2240 Verigene Processor SP and 776 Ve | 2023-06-30 |
| Luminex Corporation | UDI-DI | 2020-06-15 | Class II | Device Design | An instrument failure mode that may result in a Blood Culture Gram Positive (BC-GP) or Gram Negative (BC-GN) false negative call. | Total = 3,016 systems (2240 Verigene Processor SP and 776 Ve | 2023-06-30 |
| Luminex Corporation | UDI-DI | 2018-12-10 | Class II | Component design/selection | No results/incorrect results due to failure of the hybridization heater. | 1 system |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2019-04-22 | Class II | Under Investigation by firm | Two of three complaints were initiated due to the customers repeatedly obtaining No Call results on the Processor SPs in question. | 4 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.