Revogene Mock Pie
The MOCK PIE is a re-usable PIE intended for use in conjunction with the Revogene instrument and the Revogene assays. The MOCK Pie simulates the presence of an assay PIE for thermal and…
The MOCK PIE is a re-usable PIE intended for use in conjunction with the Revogene instrument and the Revogene assays. The MOCK Pie simulates the presence of an assay PIE for thermal and rotational balance when the number of assay PIEs is lower than eight in a run.
Who Else Makes It
Concentrated in Jiangsu (4), Shandong (3), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Orient Gene Biotech | Huzhou | Zhejiang | Contract manufacturer | 86 |
| Guangzhou Four E’s Scientific Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 61 |
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Biobase Biodustry(Shandong)Co., Ltd. | Jinan | Shandong | Manufacturer | 70 |
| Infitek Co., Ltd. | Shanghai | Shanghai | Manufacturer | 49 |
| Labpeak Co., Ltd. | Jinan | Shandong | Manufacturer | 43 |
| Scitek Global Co., Ltd. | Jinan | Shandong | Manufacturer | 43 |
| Bioteke Corporation (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Manufacturer | 21 |
| Getein Biotech, Inc. | Nanjing | Jiangsu | Manufacturer | 19 |
| Xian Tianlong Science AND Technology Co., Ltd. | Xi’An | Shaanxi | Manufacturer | 8 |
| Hangzhou Bioer Technology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 6 |
| Sansure Biotech Inc. | Changsha | Hunan | Manufacturer | 4 |
Showing 12 of 15. All 15 manufacturers in China registered for Real Time Nucleic Acid Amplification System
Record
| Listed by | Meridian Bioscience, Inc., United States |
|---|---|
| FDA product code | OOI |
| Device type | Real Time Nucleic Acid Amplification System |
| Device class | Class 2 |
| Regulation | 21 CFR 862.2570 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| Record published | 2020-06-29 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment humidity 0 to 80 % RH; Storage environment temperature -30 to 50 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 610208 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| GeneXpert Dx System | Cepheid | 37 |
| Alinity m | Abbott Molecular, Inc. | 20 |
| GeneXpert Infinity-80 System | Cepheid | 13 |
| Fluorescence Quantitative PCR Detection System | Anitoa Biotechnology(Hangzhou)Co., Ltd. | 12 |
| GeneXpert® | Cepheid | 10 |
| Certified Pre-Owned GeneXpert Dx System | Cepheid | 10 |
| Bioer GeneExplorer Thermal Cycler | Hangzhou Bioer Technology Co., Ltd. | 7 |
| m2000 | Abbott Molecular, Inc. | 5 |
| GeneXpert Infinity-48s System | Cepheid | 5 |
| Panther Fusion® | Hologic, Inc. | 4 |
| Bioer LineGene 9600 Plus Fluorescent Quantitative Detection System | Hangzhou Bioer Technology Co., Ltd. | 4 |
| Bioer QuantGene 9600 Fluorescent Quantitative Detection System | Hangzhou Bioer Technology Co., Ltd. | 3 |
Showing 12 of 188. All products under Real Time Nucleic Acid Amplification System
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K243922 | 2025-03-20 |
| K222779 | 2023-01-26 |
| K220480 | 2022-07-11 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2022-06-22 | Class II | Device Design | When a run is aborted, the cooling period protection does not occur and the user is able to open the lid prior to the completion of the cooling period, exposing the user to heated instrument components. Incidental contact with heated instru | 459 (394 US, 65 OUS) |
| 2022-02-15 | Class II | Component design/selection | The photomultiplier tube, may have compromised functionality in some instruments. As a result, the user is likely to observe an increase in false-positive or indeterminate results. | 452 units (398 US, 54 OUS) |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.