Revogene Mock Pie

The MOCK PIE is a re-usable PIE intended for use in conjunction with the Revogene instrument and the Revogene assays. The MOCK Pie simulates the presence of an assay PIE for thermal and…

Registry build 21.09.26

The MOCK PIE is a re-usable PIE intended for use in conjunction with the Revogene instrument and the Revogene assays. The MOCK Pie simulates the presence of an assay PIE for thermal and rotational balance when the number of assay PIEs is lower than eight in a run.

15manufacturers in China registered for this device type
1catalogue number
3510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Jiangsu (4), Shandong (3), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code OOI
Manufacturer City Province Registered as Device types
Zhejiang Orient Gene Biotech Huzhou Zhejiang Contract manufacturer 86
Guangzhou Four E’s Scientific Co., Ltd. Guangzhou Guangdong Contract manufacturer 61
Sanmina Kunshan Jiangsu Contract manufacturer 15
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70
Infitek Co., Ltd. Shanghai Shanghai Manufacturer 49
Labpeak Co., Ltd. Jinan Shandong Manufacturer 43
Scitek Global Co., Ltd. Jinan Shandong Manufacturer 43
Bioteke Corporation (Wuxi) Co., Ltd. Wuxi Jiangsu Manufacturer 21
Getein Biotech, Inc. Nanjing Jiangsu Manufacturer 19
Xian Tianlong Science AND Technology Co., Ltd. Xi’An Shaanxi Manufacturer 8
Hangzhou Bioer Technology Co., Ltd. Hangzhou Zhejiang Manufacturer 6
Sansure Biotech Inc. Changsha Hunan Manufacturer 4

Showing 12 of 15. All 15 manufacturers in China registered for Real Time Nucleic Acid Amplification System

Record

Regulatory record for Revogene Mock Pie
Listed by Meridian Bioscience, Inc., United States
FDA product code OOI
Device type Real Time Nucleic Acid Amplification System
Device class Class 2
Regulation 21 CFR 862.2570
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
Record published 2020-06-29

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Storage environment humidity 0 to 80 % RH; Storage environment temperature -30 to 50 °C

Catalogue Numbers

Catalogue numbers for Revogene Mock Pie
Catalogue number Size Status
610208 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
GeneXpert Dx System Cepheid 37
Alinity m Abbott Molecular, Inc. 20
GeneXpert Infinity-80 System Cepheid 13
Fluorescence Quantitative PCR Detection System Anitoa Biotechnology(Hangzhou)Co., Ltd. 12
GeneXpert® Cepheid 10
Certified Pre-Owned GeneXpert Dx System Cepheid 10
Bioer GeneExplorer Thermal Cycler Hangzhou Bioer Technology Co., Ltd. 7
m2000 Abbott Molecular, Inc. 5
GeneXpert Infinity-48s System Cepheid 5
Panther Fusion® Hologic, Inc. 4
Bioer LineGene 9600 Plus Fluorescent Quantitative Detection System Hangzhou Bioer Technology Co., Ltd. 4
Bioer QuantGene 9600 Fluorescent Quantitative Detection System Hangzhou Bioer Technology Co., Ltd. 3

Showing 12 of 188. All products under Real Time Nucleic Acid Amplification System

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K243922 2025-03-20
K222779 2023-01-26
K220480 2022-07-11

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2022-06-22 Class II Device Design When a run is aborted, the cooling period protection does not occur and the user is able to open the lid prior to the completion of the cooling period, exposing the user to heated instrument components. Incidental contact with heated instru 459 (394 US, 65 OUS)
2022-02-15 Class II Component design/selection The photomultiplier tube, may have compromised functionality in some instruments. As a result, the user is likely to observe an increase in false-positive or indeterminate results. 452 units (398 US, 54 OUS)

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer