Who Else Makes It
Concentrated in Zhejiang (6), Guangdong (2), Beijing (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Orient Gene Biotech | Huzhou | Zhejiang | Contract manufacturer | 86 |
| Hangzhou Biotest Biotech Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 41 |
| Abon Biopharm (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 17 |
| Prometheus Bio Inc. | Hangzhou | Zhejiang | Contract manufacturer | 12 |
| Hangzhou AllTest Biotech Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 48 |
| Assure Tech. (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 48 |
| W.h.p.m. Bioresearch & Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 37 |
| Guangzhou Decheng Biotechnology Co., Ltd. | Guangzhou | Guangdong | Complaint-file establishment | 35 |
| Changchun Wancheng BIO-Electron Co., Ltd. | Changchun | Jilin | Contract manufacturer | 34 |
| Co-Innovation Biotech Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 29 |
| Hongkong Conlight Medical Group Limited | Tai Kok Tsui | Hong Kong | Specification developer | 11 |
Record
| Listed by | Alere San Diego, Inc., United States |
|---|---|
| FDA product code | DJR |
| Device type | Enzyme Immunoassay, Methadone |
| Device class | Class 2 |
| Regulation | 21 CFR 862.3620 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2024-12-17 |
| Record revised | 2026-03-13 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| DMT-101 | 50 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Healgen | Healgen Scientific Limited Liability Company | 56 |
| Identify Diagnostics Drug Test Cups | Medical Distribution Group Inc | 23 |
| DOA 5 Panel Test | Rapid Diagnostics, Inc. | 20 |
| Advin Multi-Drug Screen Test | Advin Biotech, Inc. | 14 |
| ProScreen | Instant Tech Subsidiary Acquisition | 13 |
| DrugCheck | Express Diagnostics Int’l., Inc. | 12 |
| UCP Compact Drug Test Cups | UCP Biosciences, Inc. | 12 |
| MD DugScreen | Medical Disposables Corp | 12 |
| CLIAwaived | Cliawaived,inc. | 11 |
| QuickTox Drug Screen Dipcard | Branan Medical Corporation | 10 |
| U-Screen | Instant Tech Subsidiary Acquisition | 7 |
| First Sign® | Hemosure Inc. | 7 |
Showing 12 of 170. All products under Enzyme Immunoassay, Methadone
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2017-11-28 | Class III | Under Investigation by firm | The High (125 ng/ml) Control does not meet specification – it has been confirmed to produce values below 100 ng/mL when run on validated clinical chemistry analyzers, which is below the 100 ng/mL cutoff of the EDDP Specific Urine Enzyme Imm | 37 kits | 2021-01-29 |
| 2014-02-05 | Class II | Process control | Alere San Diego, Inc. is initiating a recall of the Alere Triage TOX Drug Screen, Catalog Number 94400, Lots W56013B and W56035B because Alere’s investigation has shown that these lots have a frequency of false negative results for PCP (Phe | 305 kits (239 kits of W56013B, 66 kits of W56035B) | 2014-10-27 |
| 2012-05-14 | Class II | Nonconforming Material/Component | A recall was initiated because Alere San Diego has confirmed that the Triage TOX Drug Screen may have significantly decreased precision and accuracy than claimed. An increased frequency of false positive and/or false negative results has b | 9,997 kits | 2012-12-04 |
| 2010-03-12 | Not classified | Nonconforming Material/Component | The recall was initiated because Biosite Inc. received an increase in customer calls regarding unexpected positive THC results when using the Triage TOX Drug Screen. | 1,258,002 kits | 2012-04-23 |
| 2009-05-28 | Class II | Error in labeling | Biosite is recalling the Triage TOX Drug Screen kits where the box containing test devices because it was mislabeled. | 45,638 units | 2012-10-10 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.