Bronchoscope Guide
Scope guide
Who Else Makes It
Concentrated in Guangdong (7), Zhejiang (5), Jiangsu (4). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Flexicare Medical (Dongguan) Ltd. | Dongguan | Guangdong | Contract manufacturer | 48 |
| Guangdong MacroLux Medical Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 9 |
| Ningbo Wise Optomech Technology Corporation | Ningbo | Zhejiang | Contract manufacturer | 4 |
| Hangzhou Broncus Medical Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 1 |
| Tianjin Puli Ark Medical Technology Co., Ltd. | Dongli District | Tianjin | Contract manufacturer | 1 |
| Micro-Tech (Nanjing) Co., Ltd. | Nan Jing | Jiangsu | Contract manufacturer | 49 |
| Zhejiang Huanyi Sterilization Technology Co., Ltd. | Huzhou | Zhejiang | Contract manufacturer | 25 |
| Shenzhen Hugemed Medical Technical Development Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 22 |
| Suzhou Prosteri Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Suzhou Virgil Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Scivita Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 19 |
| Anrei Medical (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 12 |
Showing 12 of 21. All 21 manufacturers in China registered for Bronchoscope (Flexible Or Rigid)
Record
| Listed by | Noah Medical Corp., United States |
|---|---|
| FDA product code | EOQ |
| Device type | Bronchoscope (Flexible Or Rigid) |
| Device class | Class 2 |
| Regulation | 21 CFR 874.4680 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| Record published | 2024-12-11 |
| Record revised | 2025-12-01 (version 2) |
Specifications
| MRI safety | MR Safe |
|---|---|
| Sterilisation | Ethylene Oxide |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Contains natural rubber latex |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10000307 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Bronchoscope (Flexible Or Rigid) | Karl Storz GmbH & Co. KG | 248 |
| Pentax | Hoya Corporation | 39 |
| Biopsy Forceps | Olympus Medical Systems Corp. | 31 |
| Single-Use flexible Video Bronchoscope | Hunan Vathin Medical Instrument Co., Ltd. | 27 |
| Pilling | Teleflex Medical LLC | 24 |
| Silicone cap | Efer Endoscopy | 22 |
| Bronchoscope (Flexible Or Rigid) | Intuitive Surgical, Inc. | 20 |
| Endoso | Hunan Endoso Life Technology Co., Ltd. | 20 |
| Exalt ™ | Boston Scientific Corporation | 17 |
| Grasping Forceps | Olympus Medical Systems Corp. | 16 |
| LungVision Tool | Body Vision Medical Ltd | 16 |
| Fujifilm | Fujifilm Corporation | 15 |
Showing 12 of 255. All products under Bronchoscope (Flexible Or Rigid)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K223144 | 2023-03-01 |
Recalls
5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2025-09-12 | Class II | Under Investigation by firm | Due to Users not having access to the Instructions for Use/User Manual due to it being password protected. | 47 |
| 2024-10-28 | Class II | Component change control | Bronchoscopic visualization system power supplies have defective semiconductor components that may fail unexpectedly, which could result in an aborted procedure since it is a non recoverable failure. Manual removal of the bronchoscope when | 18 |
| 2024-10-25 | Class II | Device Design | Not all biopsy tools meant to fit bronchoscope channel (2.1mm inner diameter/length greater or equal to 1100mm) will pass through if scope channel positioned in sharp bend (approx. greater than 100-deg.), excessive force may result in tissu | 26 |
| 2024-10-25 | Class II | Device Design | Bronchoscopic system uninterruptable power may have defective component, may cause power supply short circuit/trip protective circuit breakers causing sudden, unrecoverable power loss, which could occur while system is on mains or internal | 26 |
| 2024-03-09 | Class II | Process control | Due to a misaligned calibration of the wired controller that may result in unintended motion of the scope. | 17 wired controllers |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.