Extended Patient Introducer Mount

Catalogue number MON-000713, listed by Auris Health, Inc, United States, under Bronchoscope (Flexible Or Rigid). 21 manufacturers in China are registered for this product code.

Registry build 21.09.26
21manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code
6recalls on this code

Who Else Makes It

Concentrated in Guangdong (7), Zhejiang (5), Jiangsu (4). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code EOQ
Manufacturer City Province Registered as Device types
Flexicare Medical (Dongguan) Ltd. Dongguan Guangdong Contract manufacturer 48
Guangdong MacroLux Medical Technology Co., Ltd. Dongguan Guangdong Contract manufacturer 9
Ningbo Wise Optomech Technology Corporation Ningbo Zhejiang Contract manufacturer 4
Hangzhou Broncus Medical Co., Ltd. Hangzhou Zhejiang Contract manufacturer 1
Tianjin Puli Ark Medical Technology Co., Ltd. Dongli District Tianjin Contract manufacturer 1
Micro-Tech (Nanjing) Co., Ltd. Nan Jing Jiangsu Contract manufacturer 49
Zhejiang Huanyi Sterilization Technology Co., Ltd. Huzhou Zhejiang Contract manufacturer 25
Shenzhen Hugemed Medical Technical Development Co., Ltd. Shenzhen Guangdong Manufacturer 22
Suzhou Prosteri Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 20
Suzhou Virgil Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 20
Scivita Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 19
Anrei Medical (Hangzhou) Co., Ltd. Hangzhou Zhejiang Manufacturer 12

Showing 12 of 21. All 21 manufacturers in China registered for Bronchoscope (Flexible Or Rigid)

Record

Regulatory record for Extended Patient Introducer Mount
Listed by Auris Health, Inc, United States
FDA product code EOQ
Device type Bronchoscope (Flexible Or Rigid)
Device class Class 2
Regulation 21 CFR 874.4680
Establishment Specification developer, Repacker / relabeller, Manufacturer
510(k) K243219
Record published 2025-09-04

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, manufacturing date
Packaging Carton

Catalogue Numbers

Catalogue numbers for Extended Patient Introducer Mount
Catalogue number Size Status
MON-000713 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Bronchoscope (Flexible Or Rigid) Karl Storz GmbH & Co. KG 248
Pentax Hoya Corporation 39
Biopsy Forceps Olympus Medical Systems Corp. 31
Single-Use flexible Video Bronchoscope Hunan Vathin Medical Instrument Co., Ltd. 27
Pilling Teleflex Medical LLC 24
Silicone cap Efer Endoscopy 22
Bronchoscope (Flexible Or Rigid) Intuitive Surgical, Inc. 20
Endoso Hunan Endoso Life Technology Co., Ltd. 20
Exalt ™ Boston Scientific Corporation 17
Grasping Forceps Olympus Medical Systems Corp. 16
LungVision Tool Body Vision Medical Ltd 16
Fujifilm Fujifilm Corporation 15

Showing 12 of 255. All products under Bronchoscope (Flexible Or Rigid)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K260382 2026-07-25
K243219 2025-01-23
K211493 2021-07-09
K193534 2020-04-15

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Extended Patient Introducer Mount
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Auris Health, Inc 510(k) number 2026-01-21 Class II Software design Device for bronchoscopic visualization, patient airway access has software issue: if application restarts after patient-side selection, prior to bronchoscope loading, application will re-initialize to patient-left position; and if right pos 173

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-08-02 Class II Device Design Endoscopy/bronchoscopy/urology devices may have a strain relief defect with some cart and tower power cords that may cause an electrical short, which may lead to system shutdown, which can lead to prolonged procedure or case conversion, and 176
2023-10-18 Class II Software design Their is the potential that software issues may result in flipped image of the virtual Bronchoscope view. 110 units In total
2023-10-18 Class II Software design Their is the potential that software issues may result in flipped image of the virtual Bronchoscope view. 110 units In total
2023-10-18 Class II Software design Their is the potential that software issues may result in flipped image of the virtual Bronchoscope view. 110 units In total
2019-04-19 Class II Labeling design Reports of aspirating biopsy needle breakage 158 2022-01-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer