PlanPoint
Planning Laptop
Who Else Makes It
Concentrated in Guangdong (7), Zhejiang (5), Jiangsu (4). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Flexicare Medical (Dongguan) Ltd. | Dongguan | Guangdong | Contract manufacturer | 48 |
| Guangdong MacroLux Medical Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 9 |
| Ningbo Wise Optomech Technology Corporation | Ningbo | Zhejiang | Contract manufacturer | 4 |
| Hangzhou Broncus Medical Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 1 |
| Tianjin Puli Ark Medical Technology Co., Ltd. | Dongli District | Tianjin | Contract manufacturer | 1 |
| Micro-Tech (Nanjing) Co., Ltd. | Nan Jing | Jiangsu | Contract manufacturer | 49 |
| Zhejiang Huanyi Sterilization Technology Co., Ltd. | Huzhou | Zhejiang | Contract manufacturer | 25 |
| Shenzhen Hugemed Medical Technical Development Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 22 |
| Suzhou Prosteri Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Suzhou Virgil Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Scivita Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 19 |
| Anrei Medical (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 12 |
Showing 12 of 21. All 21 manufacturers in China registered for Bronchoscope (Flexible Or Rigid)
Record
| Listed by | Intuitive Surgical, Inc., United States |
|---|---|
| FDA product code | EOQ |
| Device type | Bronchoscope (Flexible Or Rigid) |
| Device class | Class 2 |
| Regulation | 21 CFR 874.4680 |
| Establishment | Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2019-03-21 |
| Record revised | 2026-07-28 (version 46) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 380718 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Bronchoscope (Flexible Or Rigid) | Karl Storz GmbH & Co. KG | 248 |
| Pentax | Hoya Corporation | 39 |
| Biopsy Forceps | Olympus Medical Systems Corp. | 31 |
| Single-Use flexible Video Bronchoscope | Hunan Vathin Medical Instrument Co., Ltd. | 27 |
| Pilling | Teleflex Medical LLC | 24 |
| Silicone cap | Efer Endoscopy | 22 |
| Bronchoscope (Flexible Or Rigid) | Intuitive Surgical, Inc. | 20 |
| Endoso | Hunan Endoso Life Technology Co., Ltd. | 20 |
| Exalt ™ | Boston Scientific Corporation | 17 |
| Grasping Forceps | Olympus Medical Systems Corp. | 16 |
| LungVision Tool | Body Vision Medical Ltd | 16 |
| Fujifilm | Fujifilm Corporation | 15 |
Showing 12 of 255. All products under Bronchoscope (Flexible Or Rigid)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K252045 | 2025-09-23 |
| K252528 | 2025-09-05 |
| K242070 | 2024-09-24 |
| K240135 | 2024-04-03 |
| K232984 | 2023-12-18 |
| K220299 | 2022-06-16 |
| K212048 | 2021-08-26 |
| K202370 | 2020-11-16 |
| K201146 | 2020-06-26 |
| K192367 | 2019-11-26 |
| K182188 | 2019-02-14 |
Recalls
6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-12-04 | Class II | Process control | Due to probe bags that may have a compromised or incomplete sterile pouch seal. | 110580 | |
| 2024-07-12 | Class II | Under Investigation by firm | There is a potential that the robotic system’s instrument cart arm may contain screws that may potentially fail which could result in uncontrolled motion of a catheter inside a patient’s airways. | 3 units | |
| 2021-08-06 | Class II | Under Investigation by firm | Potential for the sheath tip on the biopsy needle to separate from the sheath shaft. | 1625 units | 2024-05-17 |
| 2020-10-23 | Class II | Device Design | The distal tip ring of the fully articulating catheter may become dislodged during the procedure. | 454 catheters | 2022-12-05 |
| 2020-06-10 | Class II | Device Design | One type of the ION Catheter Reprocessing Covers (PN 490114-02) has the potential to become disengaged or incorrectly engaged to the ION Fully Articulating Catheter which can result in retention of cleaning chemical or water during reproces | 67 units | |
| 2020-06-10 | Class II | Device Design | One type of the ION Catheter Reprocessing Covers (PN 490114-02) has the potential to become disengaged or incorrectly engaged to the ION Fully Articulating Catheter which can result in retention of cleaning chemical or water during reproces | 27 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.