Drill, Surgical, Ent (Electric or Pneumatic) Including Handpiece

BUR TN30RCD Transnasal 3MM RND CRS Diamd

Registry build 21.09.26
2manufacturers in China registered for this device type
29catalogue numbers in this listing
8510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code ERL
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Guangdong Jinme Medical Technology Co., Ltd. Foshan Guangdong Manufacturer 13

Record

Regulatory record for Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece
Listed by Medtronic Xomed, Inc., United States
FDA product code ERL
Device type Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece
Device class Class 2
Regulation 21 CFR 874.4250
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K081277
Record published 2016-05-01
Record revised 2022-09-16 (version 9)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, serial number
Storage Storage environment temperature 10 to 40 °C; Storage environment temperature -40 to 70 °C
Packaging Pack of 10
Sizes Angle 15 °; length 13 cm; outer diameter 3 to 4.5 mm; length 3 to 4 mm
Distribution end date 2023-12-06
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece
Catalogue number Size Per pack Status
1898430LO In distribution
TN30RCD Outer Diameter 3.0 mm In distribution
EC300 In distribution
3318520 In distribution
3155617 In distribution
TN30MFL Length 13.0 cm In distribution
TN30MCD Outer Diameter 3.0 mm In distribution
TN40RFL Angle 15.0 ° In distribution
1898001 In distribution
TN30RFL Outer Diameter 3.0 mm In distribution
3118530 20 In distribution
IRD350 5 In distribution
1898430RF In distribution
1898430 In distribution
TN40RCD Length 13.0 cm In distribution
EC300 In distribution
3118535 20 In distribution
EDT200 In distribution
1898001RF In distribution
1898430RF In distribution
1898001 In distribution
1898001 In distribution
TN45RCD Outer Diameter 4.5 mm In distribution
1894520 In distribution
EC300 In distribution
1898430LO Withdrawn
3318510 Withdrawn
3118515 Withdrawn
1898001LO Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
ENT MR8 Medtronic Powered Surgical Solutions 234
Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece Anspach Effort, The 214
Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece Karl Storz GmbH & Co. KG 208
Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece Synthes Gmbh 126
Midas Rex Medtronic Powered Surgical Solutions 97
Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece Stryker GmbH 87
Midas REX Microsaws Medtronic Powered Surgical Solutions 75
Piezomed Pro Accessory W&H Dentalwerk Bürmoos GmbH 50
Midas Rex Clearview™ Medtronic Xomed, Inc. 47
Zethon Zethon Ltd 39
NSK Sterile Burs/Drills Nakanishi Inc. 34
Core Stryker GmbH 27

Showing 12 of 169. All products under Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K150728 2015-08-14
K081277 2008-09-05
K073255 2008-03-24
K041523 2004-07-23
K041413 2004-07-12
K011321 2001-06-26
K002224 2000-12-04
K963246 1996-09-23

Recalls Naming This Product

2 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.

Recalls naming the identifiers of Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Medtronic Xomed, Inc. 510(k) number 2021-12-15 Class II Under Investigation by firm As a result of Medtronic’s integrated power console (authentication number: 222ACBZX00018000) being used with software version: v2.7.3.0, it was discovered that there was a defect that resulted in a difference between the set number of rota 1447 units 2023-06-09
ev3, Inc. UDI-DI 2021-03-23 Class III Device Design Firm received increased number of reports that VenaSeal dispensing systems are not effectively advancing the adhesive forward through the delivery catheter. 154,152 units 2026-08-04

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-06-12 Class II Software design During internal testing execution of the next generation of Integrated Power Console (IPC) prototype it was noted that the M5 Microdebrider was rotating at a higher speed than the set value in the cosole. 673 units 2023-04-20
2009-07-17 Not classified Software design An error code (Code 13) is displayed on some of the consoles when a Medtronic Stylus or EHS handpiece is connected to the IPC indicating that the handpiece has not been recognized by the console. 493 2010-01-20

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer