Drill, Surgical, Ent (Electric or Pneumatic) Including Handpiece

3.5 mm ENT Precision Cutter Angle Agg. Serr 40 Degree ESSx/HUMMER 4 11.0 cm Working Length

Registry build 21.09.26
2manufacturers in China registered for this device type
87catalogue numbers in this listing
8510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code ERL
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Guangdong Jinme Medical Technology Co., Ltd. Foshan Guangdong Manufacturer 13

Record

Regulatory record for Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece
Listed by Stryker GmbH, Switzerland
FDA product code ERL
Device type Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece
Device class Class 2
Regulation 21 CFR 874.4250
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer
Record published 2016-09-23
Record revised 2019-11-07 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date, serial number
Storage Storage environment atmospheric pressure 50 to 106 KiloPascal; Storage environment humidity 10 to 75 % RH; Storage environment temperature -20 to 40 °C
Packaging Pack of 5, pack of 3
Sizes Length 4 to 11 cm; angle 12 to 60 °; length 3 to 25 mm
Distribution end date 2021-09-16

Catalogue Numbers

Catalogue numbers for Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece
Catalogue number Size Status
5407100000 In distribution
5290440100 Angle 40.0 ° In distribution
5100120922 In distribution
5290435100 Length 11.0 cm In distribution
5100120492 In distribution
5100010060S2 In distribution
5290011000 Diameter: 4.0 Millimeter In distribution
5290740200 Angle 40.0 ° In distribution
5290530000 Diameter: 3.5 Millimeter In distribution
2296301000 In distribution
5100120450 In distribution
5100010480 In distribution
5100010248 Length 16.0 mm In distribution
5100010210 In distribution
5407010200 Length 9.0 cm In distribution
5100120490 In distribution
5290760100 Angle 60.0 ° In distribution
5100010301 In distribution
5407-300-100 In distribution
5100010049 Diameter: 25.0 Millimeter In distribution
5100010470 In distribution
5100010301S2 Length 7.0 mm In distribution
5100120452 In distribution
5450040013 Length 4.0 cm In distribution
5100010278 In distribution
5450040000 Length 4.0 cm In distribution
5400001030 In distribution
5400121000S1 In distribution
5290638000 Diameter: 3.5 Millimeter In distribution
5450040002 Length 4.0 cm In distribution
5100120485 In distribution
5290635100 Length 11.0 cm In distribution
5407521008 Length 8.0 cm In distribution
5450040003 Length 4.0 cm In distribution
5100120920 In distribution
5100010200 In distribution
5100010272 In distribution
5407-300-000 In distribution
5290647000 Diameter: 3.0 Millimeter In distribution
5290640100 Diameter: 4.0 Millimeter In distribution
5450400000 In distribution
5290635000 Diameter: 3.5 Millimeter In distribution
5100120482 In distribution
2296302000 In distribution
5100120952 In distribution
5450040001 Length 4.0 cm In distribution
5290740100 Diameter: 4.0 Millimeter In distribution
5100120480 In distribution
5400121000 In distribution
5100010302 In distribution
5290628000 Diameter: 2.5 Millimeter In distribution
5450040011 Length 4.0 cm In distribution
5100010450 In distribution
5100010247 Length 12.0 mm In distribution
5100120470 In distribution
5100120045 In distribution
5290645000 Diameter: 4.0 Millimeter In distribution
5100010270 In distribution
5290540000 Length 8.0 cm In distribution
5100120472 In distribution
5100010301S1 Length 3.0 mm In distribution
5100010249 Length 25.0 mm In distribution
5290744100 Diameter: 4.0 Millimeter In distribution
5100010048 Diameter: 16.0 Millimeter In distribution
5290340000 Diameter: 4.0 Millimeter In distribution
5290648000 Length 8.0 cm In distribution
5100010022 Withdrawn
5100010950 Withdrawn
5100010072 Withdrawn
5100010490 Withdrawn
5100120044 Withdrawn
5100010482S1 Withdrawn
5100010090 Withdrawn
5100010920 Withdrawn
5100010501 Withdrawn
5100010922 Withdrawn
5100010052 Withdrawn
5100010952 Withdrawn
5100010050 Withdrawn
5100010070 Withdrawn
5100010020 Withdrawn
5100010080 Withdrawn
5100010452 Withdrawn
5100010011 Withdrawn
5100010472 Withdrawn
5100010482 Withdrawn
5100120950 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
ENT MR8 Medtronic Powered Surgical Solutions 234
Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece Anspach Effort, The 214
Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece Karl Storz GmbH & Co. KG 208
Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece Synthes Gmbh 126
Midas Rex Medtronic Powered Surgical Solutions 97
Midas REX Microsaws Medtronic Powered Surgical Solutions 75
Piezomed Pro Accessory W&H Dentalwerk Bürmoos GmbH 50
Midas Rex Clearview™ Medtronic Xomed, Inc. 47
Zethon Zethon Ltd 39
NSK Sterile Burs/Drills Nakanishi Inc. 34
Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece Medtronic Xomed, Inc. 29
Core Stryker GmbH 27

Showing 12 of 169. All products under Drill, Surgical, Ent (Electric Or Pneumatic) Including Handpiece

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K211490 2021-06-09
K171840 2017-09-15
K152641 2015-11-20
K141935 2014-09-26
K112593 2012-05-01
K080052 2008-10-02
K943569 1995-01-09
K940710 1994-05-16

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2014-03-18 Class II Employee error Stryker Instruments is voluntarily recalling the single use 2.5MM Aggressive Blade because the line on the affected part (P/N 5290-928-000, Lot #13280CG2) was a straight line without a number scale or logo. The line required for this part n 90 units 2014-05-15
2013-07-01 Class II Process change control The safety margin values detailed in the Engineering Design were entered incorrectly into the programming software. Handpieces that have been programmed with the incorrect parameters could result in unintended activation. There is a poten 0 2013-09-16
2013-07-01 Class II Process change control The safety margin values detailed in the Engineering Design were entered incorrectly into the programming software. Handpieces that have been programmed with the incorrect parameters could result in unintended activation. There is a poten 9 2013-09-16
2013-07-01 Class II Process change control The safety margin values detailed in the Engineering Design were entered incorrectly into the programming software. Handpieces that have been programmed with the incorrect parameters could result in unintended activation. There is a poten 11 2013-09-16

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer