Arrow

OnControl® Bone Lesion Biopsy System Tray 10ga 15cm / 12ga 19cm

Registry build 21.09.26
9manufacturers in China registered for this device type
25catalogue numbers in this listing
5recalls on this code

Who Else Makes It

Concentrated in Zhejiang (4), Jiangsu (3), Guangdong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KNW
Manufacturer City Province Registered as Device types
Zhejiang Curaway Medical Technology Co., Ltd. Hangzhou Zhejiang Contract manufacturer 7
Plexus (Xiamen) Co., Ltd., Xiamen Fujian Contract manufacturer 3
Micro-Tech (Nanjing) Co., Ltd. Nan Jing Jiangsu Contract manufacturer 49
Zhejiang Huanyi Sterilization Technology Co., Ltd. Huzhou Zhejiang Contract manufacturer 25
Jiana Sterilization Technology (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 23
Promisemed Hangzhou Meditech Co., Ltd. Hangzhou Zhejiang Contract manufacturer 21
Carbon (Shenzhen) Medical Device Co., Ltd. Shenzhen Guangdong Manufacturer 6
Canyon Medical Inc. Nanjing Jiangsu Manufacturer 4
Suzhou Leapmed Healthcare Corporation Suzhou Jiangsu Contract manufacturer 3

Record

Regulatory record for Arrow
Listed by Teleflex Medical LLC, United States
FDA product code KNW
Device type Instrument, Biopsy
Device class Class 2
Regulation 21 CFR 876.1075
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K113872
Record published 2016-09-16
Record revised 2025-07-14 (version 11)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Storage Special storage condition: Store between 15 – 30C (59 – 86F).
Packaging Case of 5, carton of 6, carton, case of 6, carton of 10, box of 10
Sizes Length 60 to 197 mm; needle gauge 10 to 13 G
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Arrow
Catalogue number Size Status
IPN033797 Length 152 mm In distribution
IPN033799 In distribution
IPN033803 Access Needle Length 102mm 10 gauge; Biopsy Needle Length 147mm 12 gauge In distribution
IPN922907 In distribution
IPN033806 Access Needle Length 102mm 11 gauge; Biopsy Needle Length 147mm 13 gauge In distribution
IPN033808 Length 60 mm In distribution
IPN033800 Length 197 mm In distribution
IPN033811 In distribution
IPN922906 In distribution
IPN056179 In distribution
IPN033741 In distribution
IPN929523 In distribution
IPN930098 In distribution
IPN927015 In distribution
IPN927014 In distribution
IPN036849 In distribution
IPN033807 In distribution
IPN926862 In distribution
IPN033836 In distribution
IPN927016 In distribution
IPN033802 In distribution
IPN033810 In distribution
IPN033796 In distribution
IPN033805 In distribution
IPN931356 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Curaway Zhejiang Curaway Medical Technology Co., Ltd. 910
SureAim Coaxial Biopsy Needle Canyon Medical Inc. 157
CorVocet™ Merit Medical Systems, Inc. 157
SureCore Automatic Disposable Biopsy Needle Canyon Medical Inc. 156
M Biopsy Automatic Disposable Biopsy Needle Canyon Medical Inc. 108
M Biopsy Coaxial Biopsy Needle Canyon Medical Inc. 89
Co-Axial Introducer Needle Argon Medical Devices, Inc. 80
SureCore Semi-automatic Disposable Biopsy Needle Canyon Medical Inc. 76
Invivo Philips DS North America LLC 71
Coaxial needle Möller Medical GmbH 68
Disposable needle for reusable biopsy gun Möller Medical GmbH 62
Remington Medical, Inc. Automatic Cutting Needle (NAC) Remington Medical, Inc. 60

Showing 12 of 692. All products under Instrument, Biopsy

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Arrow
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Arrow International, LLC (subsidiary of Teleflex, Incorporated) 510(k) number 2021-03-08 Class II Process design Difficulty inserting the biopsy ejector rod into the bone lesion biopsy cannula, preventing the biopsy sample from being collected. Use of a defective device is likely to require immediate repeat biopsy, leading to a prolonged procedure 3,756 units (US); 249 units (OUS) Expanded 810 units: 774 US
Teleflex Medical LLC 510(k) number 2016-11-08 Class II Device Design Sterility: Due to a potential incomplete seal on the outer sterile package. 2019-11-20

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-11-08 Class II Device Design Sterility: Due to a potential incomplete seal on the outer sterile package. 2019-11-20
2016-11-08 Class II Device Design Sterility: Due to a potential incomplete seal on the outer sterile package. 2019-11-20
2016-11-08 Class II Device Design Sterility: Due to a potential incomplete seal on the outer sterile package. 2019-11-20
2016-11-08 Class II Device Design Sterility: Due to a potential incomplete seal on the outer sterile package. 113,647 units 2019-11-20

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer