Atec Pearl

Breast Biopsy System FOR Biopsies Under Stereotactic OR Ultrasound Guidance

Registry build 21.09.26
9manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code
7recalls on this code

Who Else Makes It

Concentrated in Zhejiang (4), Jiangsu (3), Guangdong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KNW
Manufacturer City Province Registered as Device types
Zhejiang Curaway Medical Technology Co., Ltd. Hangzhou Zhejiang Contract manufacturer 7
Plexus (Xiamen) Co., Ltd., Xiamen Fujian Contract manufacturer 3
Micro-Tech (Nanjing) Co., Ltd. Nan Jing Jiangsu Contract manufacturer 49
Zhejiang Huanyi Sterilization Technology Co., Ltd. Huzhou Zhejiang Contract manufacturer 25
Jiana Sterilization Technology (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 23
Promisemed Hangzhou Meditech Co., Ltd. Hangzhou Zhejiang Contract manufacturer 21
Carbon (Shenzhen) Medical Device Co., Ltd. Shenzhen Guangdong Manufacturer 6
Canyon Medical Inc. Nanjing Jiangsu Manufacturer 4
Suzhou Leapmed Healthcare Corporation Suzhou Jiangsu Contract manufacturer 3

Record

Regulatory record for Atec Pearl
Listed by Hologic, Inc., United States
FDA product code KNW
Device type Instrument, Biopsy
Device class Class 2
Regulation 21 CFR 876.1075
Establishment Remanufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K042290
Record published 2016-09-30
Record revised 2024-04-11 (version 5)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries serial number
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Atec Pearl
Catalogue number Size Status
ATEC PEARL In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Curaway Zhejiang Curaway Medical Technology Co., Ltd. 910
SureAim Coaxial Biopsy Needle Canyon Medical Inc. 157
CorVocet™ Merit Medical Systems, Inc. 157
SureCore Automatic Disposable Biopsy Needle Canyon Medical Inc. 156
M Biopsy Automatic Disposable Biopsy Needle Canyon Medical Inc. 108
M Biopsy Coaxial Biopsy Needle Canyon Medical Inc. 89
Co-Axial Introducer Needle Argon Medical Devices, Inc. 80
SureCore Semi-automatic Disposable Biopsy Needle Canyon Medical Inc. 76
Invivo Philips DS North America LLC 71
Coaxial needle Möller Medical GmbH 68
Disposable needle for reusable biopsy gun Möller Medical GmbH 62
Remington Medical, Inc. Automatic Cutting Needle (NAC) Remington Medical, Inc. 60

Showing 12 of 692. All products under Instrument, Biopsy

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K262792 2026-08-12
K180233 2018-04-10
K163052 2017-03-29
K150169 2015-08-14

Recalls Naming This Product

4 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Atec Pearl
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Hologic, Inc. 510(k) number 2010-08-11 Not classified Packaging The firm received a customer complaint that the a device labeled as ATEC 0912-12 was actually ATEC 0912-20. 990 2011-04-13
Hologic, Inc. 510(k) number 2010-02-01 Not classified Employee error The product is labeled as ATEC0909-12 but it actually contains 0909-20. 190 2010-10-08
Hologic, Inc. 510(k) number 2008-09-22 Not classified Process control The distal tip of the needle may become detached and remain in the patient, requiring surgical removal. 5,120 (1,024 cases of 5) 2009-11-18
Suros Surgical Systems, Inc. 510(k) number 2006-12-15 Not classified Other The handpiece package may have an incorrect part number on the inner package. Error could result in over-penetration of the biopsy needle. 1249 handpieces 2007-05-04

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-12-15 Class II Under Investigation by firm Presence of particulates in affected devices that can be deposited into breast tissue during use. 681,870 units
2025-01-15 Class II Process control Devices presented a condition in which the inner needle separated from the hub and produced a longer throw of the inner needle or dislodgement. 55,335 units
2023-05-02 Class II Device Design The inner needle of the Sertera device is either detaching or discharging and may cause delay in surgery 756 units
2016-08-22 Class II Labeling Change Control Incorrect label on the Sertera Biopsy Kit 570 units 2017-02-03

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer